Side 1/2
Opening the lock – Using the
OPENING INDEX
The lock is shipped with the factory
combination of 50. To open, turn dial to the
LEFT passing 50 at least fi ve times then
stop when 50 lines-up with the OPENING
Index. Turn RIGHT until dial stops, this will
retract the bolt.
To open the lock using a set combination,
for EXAMPLE 10-20-30-40, use the
following procedures:
Using the OPENING Index (see Figure 1)
1. Turn the dial to the LEFT (counter-clockwise) at least fi ve complete rotations to clear
the lock; the lock is now ready to accept the combination. Never spin the dial to clear
the lock.
2. Using the OPENING index, turn the dial RIGHT (clockwise) passing the fi rst number
in the combination [10] four times. Then stop exactly on the number [10] the fi fth time.
3. Turn the dial LEFT (counter-clockwise) passing the next number in the combination
[20] three times. Then stop exactly on the number [20] the fourth time.
4. Turn the dial RIGHT (clockwise) passing the next number in the combination [30] twice.
Then stop exactly on the number [30] the third time.
5. Turn the dial LEFT (counter-clockwise) passing the last number in the combination
[40] one time. Then stop exactly on the number [40] the second time.
6. Turn the dial to the RIGHT (clockwise) to open the lock. The lock bolt is fully
retracted when the dial no longer turns right.
To lock the combination lock, turn the dial ve complete rotations to the LEFT.
Change the combination – Using the CHANGING INDEX
To change the combination, you will need to know the existing combination and have a
LA GARD 4-Wheel change key (P/N 1315). When selecting a combination choose a four
number sequence from 0 - 99, for security purposes. It is recommended that you do not
select a combination from personal data (such as birth date, phone number, etc). Never
select numbers 0 to 20 as the LAST NUMBER of the combination; this is the “Forbidden
Zone.”
OPERATING AND CHANGING INSTRUCTIONS
4-Wheel Locks
Group 1 Locks
© copyright 2008 (P/N) 12
-205 v2 •
4/08 Kaba Mas LLC
Page 1 of 2
Figure 1


Produkt Specifikationer

Mærke: Dormakaba
Kategori: Ikke kategoriseret
Model: La Gard 1947

Har du brug for hjælp?

Hvis du har brug for hjælp til Dormakaba La Gard 1947 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Dormakaba Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Elektron

Elektron Overbridge Manual

26 November 2024
Elektron

Elektron Sidstation Manual

26 November 2024
SoundTube

SoundTube IPD-RS82-EZ Manual

26 November 2024
Kramer

Kramer 4x1VB Manual

26 November 2024
Kramer

Kramer RC-63A Manual

26 November 2024
SoundTube

SoundTube IPD-HP82-EZ Manual

26 November 2024
Kramer

Kramer RK-KVM-1U-PP3 Manual

26 November 2024
Gioteck

Gioteck VX-2 (PS3) Manual

26 November 2024