tel: 0845 300 9799 customerservice@clasohlson.co.uk www.clasohlson.com/uke-mail: internet:
1 2
Water
Water
12
Ver. 20140723
Water Sensor
Art.no 36-5748 Model DSB45
Please read theentire instruction manual before using theproduct and
then save it for future reference. We reserve theright for any errors in
text or images and any necessary changes made to technical data.
In theevent of technical problems or other queries, please contact our
Customer Services.
For more information please visit www.aeotec.com for acomplete
instruction manual.
Things to consider:
Other wireless equipment using thesame frequency band can
reduce thetransmission range.
Therange of all wireless equipment depends on thetype of
obstacles located between thetransmitter and thereceiver
(e.g. aconcrete wall will interfere with thesignal more than
aplasterboard wall).
If you experience problems, try thefollowing:
Turn off any other existing wireless equipment to check whether
this is thecause of theproblem.
Reposition thewireless equipment, shorten thedistance between
thetransmitter and thereceiver or reduce thenumber of obstacles
(walls, furniture, etc.) between them.
Safety
Never subject thesensor to high temperature, dust, heavy
vibration, impacts, humidity or moisture.
Never attempt to dismantle or modify thesensor as it contains no
user-serviceable parts.
Product description
Battery powered, wireless water sensor for use with Zipabox Duo and
other Z-wave-system products, regardless of make.
Location
Detector
Thewater sensor can be used in
two ways. It can detect thepre-
sence of water in places that were
previously dry, or it can detect
theabsence of water where water
should be present. Thedetector
can be attached using theincluded
double-sided adhesive tape.
3. Set your Z-Wave control device to learning mode.
4. Push theZ-Wave button on thesensor to connect it to your
existing Z-Wave network.
5. If theconnection is successful, theLED indicator will shine steadily
for 10 minutes. During this period thesensor can be configured
from thecontrol device.
6. If thesensor needs to be re-configured later, you can press
the “Wake up” button. TheLED indicator will shine steadily for
10 minutes. During this period thesensor can be configured
from thecontrol device.
Uninstallation
1. Set your Z-Wave control device in removal mode and press
theZ-Wave button on thesensor to uninstall it.
2. TheLED indicator on thesensor will flash for 8 seconds if
theuninstallation was successful.
3. If theuninstallation was unsuccessful, theLED indicator will shine
steadily for 8 seconds.
Reset
Hold theZ-Wave button in for 20 seconds to reset thesensor to factory
settings. If theresetting was successful, theLED indicator will shine
steadily for 2 seconds.
Care and maintenance
Always remove thebatteries if theproduct is not to be used for
along time.
Clean theproduct using alightly moistened cloth. Use only mild
cleaning agents, never solvents or corrosive chemicals.
Disposal
This product should be disposed of in accordance with local regulations.
If you are unsure how to proceed, contact your local council.
Specifications
Frequency 868.42MHz
Batteries 2×AAA/LR03
Range 30 m indoors,
100m outdoors in optimum conditions
Operating temperature –10 to +60 ºC/14–140 ºF
1. Sensor
2. Detector
Detection of rising water level
Decide on anacceptable highest water level and
place thedetector in asuitable place accordingly.
Detection of sinking water level
Decide on anacceptable lowest water level and
place thedetector in asuitable place accordingly.
Sensor
Thesensor should be placed
where it is not exposed to water or
moisture, 1 metre above thefloor
and no further than 30 metres
away from thecontrol device.
Mount thesensor with thelonger
sides perpendicular to thefloor.
1. Press thebutton on
theend of thesensor
and remove thebase.
2. Attach thebase to awall using
theincluded screws or double-
sided adhesive tape.
Note: If you mount thesensor using screws, first make sure that there
are no hidden electrical cables or water pipes in thewall/ceiling which
could be damaged by drilling themounting holes.
Installation
1. Press thebutton on theend of thesensor and
remove thebase.
2. Remove theplastic tab to activate
thebatteries. TheLED indicator on thesensor
willash for 8 seconds.


Produkt Specifikationer

Mærke: Aeon Labs
Kategori: Ikke kategoriseret
Model: DSB45

Har du brug for hjælp?

Hvis du har brug for hjælp til Aeon Labs DSB45 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Aeon Labs Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Festo

Festo EAPR-E17-S Manual

17 November 2024
Shure

Shure MVi Manual

17 November 2024
Festo

Festo EAPM-L2-SH Manual

17 November 2024
Festo

Festo OVEL Manual

17 November 2024
Festo

Festo KVZB Manual

17 November 2024
Festo

Festo EPCC-BS-45 Manual

17 November 2024
Festo

Festo CAMC-G-S1 Manual

17 November 2024
Festo

Festo CAFM-X4-H Manual

17 November 2024