AV FOR AN IT WORLD
®
QUICK START GUIDE
MT-1002 10” Modero G5 Tabletop Touch Panel
Overview
The MT-1002 (FG5969-47) 10Modero G5 Tabletop Touch Panel features the
G5 Graphics Engine, Quad Core Processor, and a capacitive multi-touch
display. The touch panel features advanced technology empowering users
to operate AV equipment seamlessly, while providing the ultimate in audio
and video quality.
Sleep button
USB Port
(side view)
FIG. 1 MT-1002
Product Specifications
MT-1002 SPECIFICATIONS
Dimensions (HWD) 6 3/16” x 10 1/16” x 4 1/16” (157mm x 255mm x 103mm)
Weight 2.6 lbs (1.179 Kg)
Power
Consumption
Full-On: 14.5 W maximum
Standby: 5.8 W
Shutdown: 1 W
Start-Up Inrush Current: Not applicable due to PoE standard
External Power
Supply Required
Optimal performance requires use of one of the following AMX PoE
power supplies (not included):
PS-POE-AT-TC, PoE Injector, 802.3AT Compliant (FG423-84)
NXA-ENET8-POE+, Gigabit PoE Ethernet Switch (FG2178-64)
Certications FCC Part 15 Class B
CE EN 55032, 55035, 60950-1
IEC 60950-1
AS/NZS CISPR 32 Class B
IC CISPR 22 Class B
UL 60950-1
VCCI CISPR 22 Class B
RoHS
WEEE
Environmental Temperature (Operating): 32°F to 104°F (0°C to 40°C)
Temperature (Storage): 4°F to 140°F (-20°C to 60°C)
Humidity (Operating): 20% to 85% RH
Humidity (Storage): 5% to 85% RH
Power (“Heat”) Dissipation: On: 49.5 BTU/hr, Standby: 19.8 BTU/hr
Included
Accessories
MXA-USB-C, USB Port Cover Kit (60-5968-29)
Cat5e Ethernet Cable, Flat Black (ECA2265-10)
UTP CAT.5E Snap In Coupler, Black (64-5968-01)
Connector Locations
USB peripherals (mouse, keyboard, etc.) may be connected to the USB port on
the rear of the device. Updates to the device’s rmware can also made via the
USB port.
USB Port
Speaker
RJ-45 Port
FIG. 2 MT-1002 (REAR VIEW)
Power via Power Over Ethernet
Power for the MT-1002 is supplied via Power Over Ethernet (PoE), utilizing an
AMX-certied, capacitive touch-compliant PoE injector such as the PS-POE-
AT-TC, PoE Injector, 802.3AT Compliant ( ) or other approved AMX PoE FG423-84
power source. The incoming Ethernet cable should be connected to the RJ45
port on the panel.
Powering On/Off Modero G5 Panels
Modero G5 touch panels may be powered on by touching and holding the
Sleep button. To power off the panel, press and hold the Sleep button, and
select on the on-screen menu (FIG. 3):Power Off
FIG. 3 SLEEP BUTTON - PRESS AND HOLD TO ACCESS POWER OFF/SETTINGS OPTIONS
Configuration and Programming
Modero G5 touch panels are equipped with a menu that provides theSettings
ability to congure various features on the panels. To access the Settings menu,
press and hold the Sleep button, and select .Settings
Note: Information on the Settings menu, panel conguration, and programming
is provided in the Modero G5 Programming Guide, available at www.amx.com.
Setting the Panels Device Number and Device Name
1. In the Settings menu, select . This opens a password keypad.NetLinx
2. Enter the panel password into the keypad (the default is ) and select 1988
OK to access the page.NetLinx
3. Press to open the NetLinx editing window.Device Number
4. Enter a unique Device Number assignment for the panel and press .OK
5. Enter a unique Device Name assignment for the panel and press .OK
Configuring the Panels IP Address
The rst step is to congure the panel’s IP address. Note that this only congures
the panel to communicate with a network; it is still necessary to connect to the
NetLinx Master ( ).see Connecting to a NetLinx Master below
Network Communication via DHCP
1. In the page, press Ethernet DHCP/Static eld to open the DHCP/Static
window. Note that is the default setting.DHCP
2. Select , enter the new host nameHost Name
3. Press to save changes.OK
Network Communication via Static Address
1. In the page, press to open the window.Ethernet DHCP/Static DHCP/Static
2. Select to open the window.Static Static IP
3. Press any eld to open a keypad or keyboard (depending on the eld), and
enter the appropriate network address information.
4. Press to save your changes and return to the page.OK Ethernet


Produkt Specifikationer

Mærke: AMX
Kategori: niet gecategoriseerd
Model: MT-1002

Har du brug for hjælp?

Hvis du har brug for hjælp til AMX MT-1002 stil et spørgsmål nedenfor, og andre brugere vil svare dig




niet gecategoriseerd AMX Manualer

AMX

AMX TPC-WIN8-TAB Manual

4 September 2024
AMX

AMX NMX-DEC-N1222A Manual

4 September 2024
AMX

AMX NMX-DEC-N2222A Manual

4 September 2024
AMX

AMX NMX-DEC-N1233 Manual

4 September 2024
AMX

AMX NMX-DEC-N2211 Manual

4 September 2024
AMX

AMX NMX-ENC-N1134A Manual

4 September 2024
AMX

AMX NMX-ENC-N1133 Manual

4 September 2024
AMX

AMX NMX-ENC-N2315-WP Manual

4 September 2024
AMX

AMX MXA-STMK-07 Manual

30 August 2024
AMX

AMX MXD-701 Manual

30 August 2024

niet gecategoriseerd Manualer

Nyeste niet gecategoriseerd Manualer

Pioneer

Pioneer CA-R-CG.001 Manual

18 September 2024
Pioneer

Pioneer CA-R-MAC.001 Manual

18 September 2024
Pioneer

Pioneer CA-R-PI.187 Manual

18 September 2024
NEC

NEC LED-FE019i3 Manual

18 September 2024
Exquisit

Exquisit EKS180-4-060E Manual

18 September 2024
Smeg

Smeg SA661X Manual

18 September 2024
Pioneer

Pioneer CA-R-TOY.003AE Manual

18 September 2024
Pioneer

Pioneer CA-R-LA.001 Manual

18 September 2024
SereneLife

SereneLife SLTLWS550 Manual

18 September 2024
SereneLife

SereneLife SLTLWS650 Manual

18 September 2024