Connect Equipment
SurgeArrest® Surge Protector
User’s Manual
Connect Battery
Power On
990-2124 Copyright © 2003 American Power Conversion. All rights reserved. APC is a registered trademark of American Power Conversion
All other trademarks are property of their respective owners.
The APC SurgeArrest Surge Protector + Battery Backup is shipped with the battery disconnected. The unit will not operate until the battery is connected.
NOTE: Small sparks may occur during battery connection. This is normal.
Surge Protection
These outlets provide full-time protection from surges even if
the unit is switched OFF. Plug your printer, fax machine,
scanner, or other peripheral that does not need battery power
into these outlets.
Battery Backup + Surge Protection
These outlets are powered whenever the unit is switched ON.
During a power outage or other utility problems (brownouts, over-
voltages), these outlets will be powered for a limited time by the
internal battery. Plug your computer and 17” (or smaller) monitor,
into these two outlets.
Connect FAX/Modem/Phone
The unit protects a single line (2-wire) fax, modem or phone from surges when it is
connected as shown below.
Connect AC Line Cord
Connect the AC line cord to a 230-volt outlet.
The Surge Protector + Battery Backup should be
allowed to charge for at least 16 hours to ensure
sufficient runtime. The unit is being charged
whenever it is connected to utility power, and the
unit is turned ON.
Power ON the unit by pressing the ON/OFF button.
Turn on your equipment.
The Surge Protector + Battery Backup provides status indications through the flashing
of the “Power On” indicator, as well as audible beeps. The indications are as follows:
Status Visual Indications Audible
Indication
Alarm Terminates
When
On Line - Unit is supplying
conditioned utility power to your
equipment
Power On LED - ON None n/a
On Battery - Unit is supplying battery
power to the equipment connected to
the battery powered outlets
Power On LED - ON
(off during beep)
Beeping 4 times
every 30 seconds
Unit returns to an On
Line status or when
the unit is turned off.
Low Battery Warning - Unit is
supplying battery power and the
battery is nearly depleted. Once
depleted, the unit will turn off.
Power On LED -
Flashing
Rapid beeping
(one second
intervals)
Unit is turned OFF,
returns to On Line or
when the battery is
finally exhausted and
the unit turns off.
Replace Battery - Battery may need
to be replaced, or the battery is not
connected.
Power On LED -
Flashing
Continuous tone. Unit is turned OFF
and then ON and it
passes a subsequent
battery test. (This test
occurs automatically
whenever the unit is
turned ON and every
14 days)
Overload Shutdown - During On
Battery operation a battery-power
outlet was overloaded.
Power On LED -
OFF
Continuous tone. Unit is turned off
using the ON/OFF
button.
Status Indications
Telephone Wall
Fax/Modem/Phone
+ Battery Backup (BE325-UK)
32 - 104
o
F (0 - 40
o
C)
Note: The on/off switch is illuminated when in the ON position.
The switch may flash to indicate changing power conditions
(see Status Indications).
Circuit
Breaker
AC Line
Cord
230-Volt Wall
Outlet
Outlet
w
w
w
.apc.com
®
Battery Backup plus Surge Protection
Surg e P ro te cti on
Side View
Top View
Push to Reset
Circuit Breaker
RJ-11
Connectors
End View
End View
Top View
Battery Backup plus Surge Protection
2
5
134
w
w
w
.apc.com
Surge Protector
+ Battery Backup
325VA
w
w
w
.apc.com
Surge Protector
+ Battery Backup
325VA
Produkt Specifikationer
Mærke: | APC |
Kategori: | Server |
Model: | BE325-UK |
Har du brug for hjælp?
Hvis du har brug for hjælp til APC BE325-UK stil et spørgsmål nedenfor, og andre brugere vil svare dig
Server APC Manualer
26 September 2024
18 September 2024
11 August 2024
11 August 2024
7 August 2024
31 Juli 2024
30 Juli 2024
28 Juli 2024
28 Juli 2024
27 Juli 2024
Server Manualer
- Server QNAP
- Server Bosch
- Server Acer
- Server Sony
- Server HP
- Server D-Link
- Server Asus
- Server Gigabyte
- Server Toshiba
- Server Lenovo
- Server Abus
- Server Planet
- Server Black Box
- Server TRENDnet
- Server Buffalo
- Server Medion
- Server Linksys
- Server Megasat
- Server Cisco
- Server Seagate
- Server Netgear
- Server Tripp Lite
- Server Western Digital
- Server Technics
- Server Digitus
- Server Dell
- Server Fujitsu
- Server NEC
- Server LevelOne
- Server FLIR
- Server ZyXEL
- Server Eaton
- Server ELAC
- Server Synology
- Server Hikvision
- Server Monacor
- Server AVerMedia
- Server Asustor
- Server Kramer
- Server Hanwha
- Server LaCie
- Server Naim
- Server Fantec
- Server Provision-ISR
- Server Quantum
- Server Axis
- Server ACTi
- Server Digi
- Server ATen
- Server Teo
- Server Vimar
- Server Smart-AVI
- Server Intel
- Server Supermicro
- Server StarTech.com
- Server Conceptronic
- Server Rocstor
- Server IStarUSA
- Server Blackmagic Design
- Server Lindy
- Server Veritas
- Server Promise Technology
- Server Sitecom
- Server HGST
- Server AMX
- Server Intellinet
- Server Iomega
- Server Silverstone
- Server Geovision
- Server Ernitec
- Server KanexPro
- Server Gefen
- Server Moxa
- Server C2G
- Server Allnet
- Server Maxdata
- Server Matrox
- Server Valcom
- Server Freecom
- Server Revox
- Server G-Technology
- Server Areca
- Server SEH
- Server Ibm
- Server Sonnet
- Server TAIDEN
- Server SIIG
- Server Advantech
- Server Mobotix
- Server Extron
- Server Avocent
- Server Silex
- Server In Win
- Server Sun
- Server Atlona
- Server MvixUSA
- Server Dual Bay
- Server Raidsonic
- Server EMC
- Server Infortrend
- Server Opengear
- Server EXSYS
- Server Raritan
- Server Chenbro Micom
- Server Mr. Signal
- Server Atlantis Land
- Server Lantronix
- Server NETSCOUT
- Server Origin Storage
- Server IMC Networks
Nyeste Server Manualer
19 November 2024
19 November 2024
14 November 2024
13 Oktober 2024
12 Oktober 2024
12 Oktober 2024
11 Oktober 2024
11 Oktober 2024
11 Oktober 2024
10 Oktober 2024