APC BE650G Manual
Læs nedenfor 📖 manual på dansk for APC BE650G (2 sider) i kategorien UPS. Denne guide var nyttig for 4 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
Back-UPS ES 650
User’s Guide
1
2
3
Connect Battery
Equipment
Power On and
Install Software
990-4995 Copyright © 2007 American Power Conversion Corp.
All other trademarks are property of their respective owners.
Surge Protection
These outlets provide full-time protection from surges even if the
Back-UPS ES is switched OFF. Plug your printer, fax machine,
scanner, or other peripherals that do not need battery power into
these outlets.
Battery Back-up +Surge Protection
These outlets are powered whenever the Back-UPS ES is
switched ON. During a power outage or other utility problems
(brownouts, over-voltages), these outlets will be powered for a
limited time by the Back-UPS ES. Plug your computer,
monitor, CD-ROM drive and two other data-sensitive devices
such as an external disk or tape drive, or Home Phoneline
Networking Association (HPNA) device into these outlets.
Press the ON/OFF switch to power the unit
ON.
A single short beep and the green “Power On”
indicator confirms the Back-UPS ES is on and
ready to provide protection.
The Back-UPS ES should charge for at least 16
hours to ensure sufficient runtime. The unit is
being charged whenever it is connected to utility
power, whether the unit is turned ON or OFF.
If the red Building Wiring Fault indicator (located
on the end near the power cord) is lit, your
building wiring presents a shock hazard that
should be corrected by a qualified electrician.
Install the PowerChute® Personal Edition
software
Place the PowerChute Personal Edition CD-
ROM into your computer and follow the
installation instructions on the screen.
w
w
w
.apc.com
®
APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.
The Back-UPS ES indicates operating status using a combination of visual and audible indicators.
Use the following table to identify the status of the Back-UPS ES.
Status Visual Indications
(Power On - Green)
(Replace Battery - Red)
Audible Indication Alarm Terminates
When
Power On - UPS is supplying conditioned
utility power to the load. Power On pushbutton -
ON (lit) None Not applicable.
On Battery - UPS is supplying battery
power to the load connected to the Battery
outlets.
Power On pushbutton -
ON (off during beep) Beeping 4 times every
30 seconds UPS transfers back to
Power On operation, or
when UPS is turned off.
Low Battery Warning - UPS is supplying
battery power to the load connected to the
battery outlets, and the battery is near
exhaustion.
Replace Battery indicator
is flashing Rapid beeping (every
1/2 second) UPS transfers back to
normal operation, or
when UPS is turned off.
Replace Battery - The battery is
disconnected.
The battery is in need of charging, or is at
the end of its usual life and must be
replaced.
Replace Battery indicator
is Flashing
Power On and Replace
Battery indicators -
flashing (alternating)
Constant tone
Constant tone
UPS is turned off with
the power switch.
Overload Shutdown - During On Battery
operation a battery power supplied outlet
overload was detected.
None Constant tone UPS is turned off with
the power switch.
Sleep Mode - During On Battery operation
the battery power has been completely
exhausted and the UPS is waiting for utility
power to return to normal.
None Beeping once every 4
seconds Utility power is restored,
or if utility power is not
restored within 32
seconds, or the UPS is
turned off.
Building Wiring Fault - Your building
wiring presents a shock hazard that should
be corrected by a licensed electrician.
Building Wiring Fault LED
(red) - ON None UPS is unplugged, or
UPS is plugged into a
properly wired outlet.
Status Indicators
®
See the Troubleshooting section for additional assistance.
For safety, the Back-UPS ES is shipped with one battery wire disconnected. The UPS will not operate until the wire is connected to the touch-safe
battery terminal. NOTE: Small sparks may occur during battery connection. This is normal.
Turn the Back-UPS ES over and press in the
release tab. Slide the plastic battery cover
off of the Back-UPS.
Insert the battery back into the compartment.
Slide the plastic battery cover until the release
tab locks into place.
Connect the red battery wire firmly to
the positive (+) battery terminal.
1 2 3
Connect
Connect Modem / Phone / DSL / Fax / 10/100Base-T / HPNA / Cable Modem / CATV
or DSS to Surge Protection
The Back-UPS protects a single line (2-wire) phone (including Digital Subscriber Line -
DSL), Home Phoneline Networking Association (HPNA) type equipment, modem, 10/100
Base-T Ethernet, or fax machines from surges when connected through the UPS as
shown in the drawing below.
The UPS also protects a cable modem, CATV converter, or DSS receiver from surges
when it is connected through the UPS coaxial connectors as shown in the drawing below.
Place the Back-UPS ES to avoid:
- Direct sunlight
- Excessive heat
- Excessive humidity or contact with fluids
Plug the Back-UPS ES power cord directly into a wall outlet; not into a surge
protector or power strip.
Connect Computer Cable
The supplied cable and software provide automatic file saving and shutdown of the
operating system in the case of a sustained power outage.
Connect the cable to the Data Port of the Back-UPS ES. Connect the other end of the
cable to the USB port on your computer. The software will automatically find the
computer’s USB Port.
BATTERY DOOR
RELEASE TAB
Power On/Off
Switch & Indicator
Replace
Battery
Indicator
NOTE:
Replace Battery Indicator is only visible when illuminated.
Circuit Breaker
Push to Reset
From Wall
Outlet Dataline outpu to
em, Fa x, or
t DSL,
Mod Network
(10/100BASE-T)
Data Port
Cable output to Cable Modem,
CATV converter or DSS input
Cable i nput from Internet Service
Provider (ISP), CATV or DSS
Produkt Specifikationer
Mærke: | APC |
Kategori: | UPS |
Model: | BE650G |
Har du brug for hjælp?
Hvis du har brug for hjælp til APC BE650G stil et spørgsmål nedenfor, og andre brugere vil svare dig
UPS APC Manualer
11 December 2024
11 December 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
UPS Manualer
- UPS Ikea
- UPS CyberPower
- UPS AEG
- UPS HP
- UPS GYS
- UPS Lenovo
- UPS Gembird
- UPS Tripp Lite
- UPS Digitus
- UPS Dell
- UPS EnerGenie
- UPS Voltcraft
- UPS JUNG
- UPS Eaton
- UPS V7
- UPS Conceptronic
- UPS Emerson
- UPS LC-Power
- UPS SurgeX
- UPS Equip
- UPS Murr Elektronik
- UPS Furman
- UPS Block
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Middle Atlantic
- UPS Minuteman
- UPS Riello
- UPS Maruson
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nyeste UPS Manualer
14 December 2024
14 December 2024
10 December 2024
10 December 2024
8 December 2024
4 Oktober 2024
3 Oktober 2024
2 Oktober 2024
2 Oktober 2024
2 Oktober 2024