APC P62 Manual


Læs nedenfor 📖 manual på dansk for APC P62 (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 4 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
990-3885D 09/2015
Es ntia urgeA est P62/P66/P610/P6Nse l S rr Protector contra sobretensión Essential
Surg rest P62/P66/P610/P6NeAr
Informations de contact : assistance technique www.apc.com; assistance téléphonique 888 272 3858Contact formation: Technical pport www pc.com; Telephone port 888 272 3858In Su .a Sup Información de contacto: Asistencia técnica www.apc.com; Asistencia telefónica 888 272 3858
Parasurt seu Essential SurgeArrest en r
P62/P66/P610/P6N
Sécurité
• Le parasurtenseur SurgeArrest est conçu pour une u lisation en intérieur uniquement. Ses ti
composants internes ne sont pas hermétiquement scellés.
• N'installez pas le SurgeArrest dans un endroit excessivement humide ou chaud.
• N'utilisez pas de rallonge avec le SurgeArrest.
Branchez le SurgeArrest uniquement sur une prise à trois fils reliée à la terre. Modèle P6N : si le
voyant de panne au niveau dublage du bâtiment s'allume pour indiquer un défaut de câblage
du bâtiment, cessez toute u isationtil de l'appareil et demandez à un électricien qualifié de vérifier
les éléments suivants au niveau du câblage du bâtiment : surcharge du circuit neutre, inversion de
la polarité ou mise à la terre incorrecte. : a urez-vous de la sécurité du Modèles P62/P66/P610 ss
câblage du bâtiment avant de brancher l'appareil sur une prise secteur.
• N'installez j aam is un appareil électrique pendant un orage.
: si le SurgeArrest est prévu pour la protection d'un réseau, reliez-le uniquement à Modèle P6N
un câble CAT5, Ethernet 10/100 BaseT.
Voyants, connecteurs et bo onsut
Interrupteur Marche/Ar t et di oncteur : sj l'interrupteur Marche/Arrêt permet de mettre sous
et hors tension toutes les prises et fait office de disjoncteur. Dans le cas d'une surcharge de la
sortie, l'interrupteur Marche/Arrêt passe en position Arrêt. Débranchez tous les équipements du
SurgeArrest avant de placer l'interrupteur en posi on Marche.ti
Protection activée : le voyant est normalement allumé pour indiquer que la protection contre les
surtensions est activée et que les équipements reliés sont protégés. Si le voyant n'est pas allumé,
cela signifie que le circuit de protection contre les surtensions est compromis. Contactez APC à
l'aide des informations de contact figurant dans ce guide.
Panne au niveau du câblage du bâtiment - modèles P6N : le voyant s'allume en cas de panne du
circ t de mise à la terre, de surcharge du circuit neutre ou d'inve ion de la polarité dans le ui rs
câblage du bâtiment. La protection n'est pas garantie lo que le voyant est allumé. Demandez à un rs
électricien qualifié de c riger le câblage du bâtiment.or
Conn teur de prot tion réseau ec ec - : ce connecteur protège les câbles de données modèles P6N
Ethernet des surtensions. Reliez le connecteur de protection contre les surtensions au seIn cteur à
l'aide d'un ble réseau. Reliez une extrémité d'un autre câble réseau au connecteur de otection pr
contre s surtensions le To Equipment et l'autre extrémité à un routeur ou un modem.
Caractéristiques
Garantie limitée
Tension nominale de
foncti nementon
Intensité maximale
Dissipation d'énergie
Longueur du cordon
d'alimentation
Dimensions
H x l x P
Seguridad
• El SurgeArrest está diseñado únicamente para uso en interiores. Los componentes internos no
están sellados para uso en exteriores.
• No instale el SurgeArrest donde el nivel de calor o humedad sean excesivos.
• No u ice cables de extensión con el SurgeArrest.til
• Enchufe el SurgeArrest únicamente a un r eptáculo trifásico, con conexión a tierra. ec Modelo
P6N: Si el LED de fallos en el cableado del edificio se enciende para indicar un fallo en el
cableado, interrumpa el uso del equipo y haga que un electricista cualificado revise el cableado
del edificio en busca de un conductor neutro sobrecargado, polaridad invertida o falta de
conexión a tierra. : Verifique la seguridad del cableado del edificio Modelos P62/P66/P610
antes de conectar la unidad a una toma de pared.
• Nunca instale cableado eléctrico durante una tormenta eléctrica.
: Si se va a usar el SurgModelo P6N eArrest para prot ción de red, conéctelo solo a un cable ec
CAT5, Ethernet 10/100 BaseT.
Indicadores, conectores e interruptores
Interruptor ON/OFF (encendido/apagado) y disyuntor de circuito: El inte uptor rr ON/OFF
(encendido/apagado) permite encender y apagar el control de alimentación de todas las tomas y
funciona como disyuntor de circuito. Cuando ocurre una condición de sobretensión de salida, el
inte uptor (encendido/apagado) se desplaza a la posición OFF (apagado). Desconecte rr ON/OFF
todo el equipo del SurgeArrest antes de desplazar el interruptor a la posición de ON (encendido).
Protección activada: El LED está normalmente encendido para indicar que el protector contra
sobretensión está encendido y listo para proteger el equipo conectado. Si el LED no se ha
encendido, la circuitería de supresión de la sobretensión está dañada. Póngase en contacto con
APC a través de la información de contacto que se incluye en esta guía.
Fallos en el cableado del edificio- : El LED se enciende cuando no hay circuito a Modelos P6N
tierra o existe un conductor neutro sobrecargado o una polaridad invertida en el cableado del
edificio. La protección no está garantizada cuando el LED está encendido. Haga que un
electricista cua ficado repare el cableado del edificio.li
Conector de la prot ción de redec -Modelos P6N: Este conector o e prot ción contra las frec ec
sobretensiones producidas a través de las líneas de datos Ethernet. Conecte un cable de red desde
el conector de pared al conector de prot ción contra sobretensión etiquetado . Conecte un ec In
extremo de otro cable de red al conector de protección contra sobretensión etiquetado
To Equipment y el otro extremo a un enrutador o módem.
Especificaciones
Garantía limitada
Tensión minal de no
funcionamiento
Amperaje máximo
Valor en julios
Longitud del cable
Dimensiones
Alto x Ancho x Fondo
Safety
• The Surge est is intended for indoor use only. The internal components are not sealed om the Arr fr
environment.
• Do not install the SurgeArrest where there is excessive heat or humidity.
• Do not use extension cords with the Surge est.Arr
• Plug the Surge est into a three wire, grounded receptacle only. : If the Arr P6N model Building
Wiring Fault LED illuminates indica ng a wiring faul discontinue use ati t, nd have a qua fied li
electrician check the building wiring for an overloaded neutral, reversed polarity, or a missing
ground. : Verify the safety of the bu ding wiring prior to connecting theP62/P66/P610 models il
unit to a wall outlet.
Never install electrical wiring during a lightning storm.
: If the SurgeArrest is to be used for network protection, connect only to CAT5, P6N model
Ethernet 10/100 Base T service.
Ind Coicators, nnectors and Switches
ON/OFF switch and circuit breaker ON/OFF-The switch provides on/off power control to all of
the outlets and serves as a circuit breaker. When an output overload condition oc rs the cu ON/OFF
switch moves to the OFF position. Disconnect all equipment from the SurgeArrest before moving
the itch to the ON pos ion.sw it
Protection Working-The D i normally luminated indicatLE s il ing that the surge protector is on and
ready to protect connected equipment. If the LED is not illuminated the surge suppression circ try ui
has been compromised. Contact APC using the contact in rmation provided in this guide.fo
Building Wiring Fault- : The LED luminates when there is no ground circu , an P6N models il it
overloaded neutral, or there is a reversed polarity in the building wiring. Protec on is nti ot guaranteed
when LED is illuminated. Have a qualified electrician correct the building wiring.
Network protection connector-P6N model: This connector provides protection from surges
traveling over Ethernet data lines. Connect a network cable om the wall connector to the surge fr
connector labeled . Connect one end of another network cable to the surge connector labeled In
To Equipment, and the other end to a router or modem.
Specifications
Limited Warranty
Nominal
Operating Voltage
Maximum Amperage
Joule Rating
Cord Length
Dimensions
H x W x D
P62 P610P66 P6N
120 Vac, 50-60 Hz
15 A
seluoJ 0801seluoJ 045
1 m (2.5 ft) 3 m (10 ft) 1.2 m (4 ft)1.8 m (6 ft)
3.5 cm x 5 cm x 25 cm
1.4 in x 2 in x 10 in
3.5 cm x 5 cm x 32 cm
(1.4 in x 2 in x 12.6 in)
P62 P610P66 P6N
120 Vac, 50-60 Hz
15 A
seluoJ 0801seluoJ 045
1 m (2.5 ft) 3 m (10 ft) 1.2 m (4 ft)1.8 m (6 ft)
3.5 cm x 5 cm x 25 cm
1.4 in x 2 in x 10 in
3.5 cm x 5 cm x 32 cm
(1.4 in x 2 in x 12.6 in)
P62 P610P66 P6N
120 Vac, 50-60 Hz
15 A
seluoJ 0801seluoJ 045
1 m (2.5 ft) 3 m (10 ft) 1.2 m (4 ft)1.8 m (6 ft)
3.5 cm x 5 cm x 25 cm
1.4 in x 2 in x 10 in
3.5 cm x 5 cm x 32 cm
(1.4 in x 2 in x 12.6 in)
TM
APC by Schneider Electric warrants its Surge Protectors to be free from defects in materials and
workmanship under normal use and service for the lifetime of the original purchaser. Schneider Electric
IT (SEIT) obligation under this warranty is limited to repairing or replacing, at its own sole option, any
such defective products. Repair or replacement of a defective Product or part thereof does not extend the
original warranty period.
© 2015 APC by Schneider Electric. APC, the APC logo are owned by Schneider Electric Industries
S.A.S., or their affiliated companies. All other trademarks are property of their respective owners.
APC by Schneider Electric garantit à l'acheteur d'origine que ses parasurtenseurs sont exempts
de tout défaut matériel et de fabrication dans des conditions normales d'utilisation, pour toute leur
durée de vie. Les obligations d'Schneider Electric IT (SEIT) aux termes de cette garantie sont
limitées à la réparation ou au remplacement, à sa seule discrétion, des produits défectueux. La
réparation ou le remplacement d'un produit défectueux ou d'une pièce de celui-ci n'étend pas la
période de garantie d'origine.
TM
© 2015 APC by Schneider Electric. et le logo APC sont la propriété de Schneider Electric Industries
S.A.S., ou de leurs sociétés affiliées. Toutes les autres marques commerciales sont la propriété de
leurs détenteurs respectifs.
APC by Schneider Electric garantiza los protectores contra sobretensión contra defectos de materiales y de
fabricación siempre que se les dé un uso normal y reciban mantenimiento por parte del comprador original
durante toda la vida útil del dispositivo. De acuerdo con esta garantía, la obligación de Schneider Electric
IT (SEIT) se limita a reparar o reemplazar, a su sola discreción, cualquier producto defectuoso. La
reparación o sustitución de un producto defectuoso o parte de él no implica la ampliación del período de
garantía original.
TM
© 2015 APC by Schneider Electric. APC, the APC logo son propiedad de Schneider Electric
Industries S.A.S., o sus empresas afiliadas. Todas las demás marcas comerciales son propiedad de
sus respectivos titulares.


Produkt Specifikationer

Mærke: APC
Kategori: Ikke kategoriseret
Model: P62
Vekselstrømsindgangsfrekvens: 50 - 60 Hz
Bredde: 51 mm
Dybde: 38 mm
Højde: 286 mm
Vægt: 320 g
Produktfarve: Hvid
Pakkedybde: 38 mm
Pakkebredde: 83 mm
Pakkehøjde: 295 mm
Opbevaringstemperatur (T-T): -15 - 45 °C
Relativ luftfugtighed ved drift (H-H): 0 - 95 %
Relativ luftfugtighed ved opbevaring (H-H): 0 - 95 %
Driftstemperatur (T-T): 0 - 40 °C
Certificering: UL 1449 TVSS Rating 500V\nETL
Kabellængde: 0.6 m
Bæredygtighedscertifikater: RoHS
Driftshøjde: 0 - 3000 m
Ikke-drift højde: 0 - 15000 m
Strømstik: NEMA 5–15R
Nominel indgangsspænding: 120 V
AC udgange, antal: 6 AC stikkontakt(er)
AC stikkontakt typer: NEMA 5–15R
Overspænding energivurdering: 540 J
Spidsstrøm, normal tilstand: 26000 A
Spidsstrøm, almindelig modus: 36000 A

Har du brug for hjælp?

Hvis du har brug for hjælp til APC P62 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret APC Manualer

APC

APC C2C Manual

17 September 2024
APC

APC AP7868 Manual

17 September 2024
APC

APC P8VNTG Manual

17 September 2024
APC

APC P62 Manual

17 September 2024
APC

APC AP7898 Manual

17 September 2024
APC

APC AP7811 Manual

17 September 2024
APC

APC PDIY7 Manual

15 Juli 2024
APC

APC P7GB Manual

15 Juli 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

SereneLife

SereneLife SLCPTBOV120 Manual

19 September 2024
Pioneer

Pioneer CA-R-PI.131 Manual

19 September 2024
Pioneer

Pioneer DEH-3910MP Manual

19 September 2024
Pioneer

Pioneer CA-R-FOR.016AE Manual

19 September 2024
Pioneer

Pioneer FH-X360UB Manual

19 September 2024
Pioneer

Pioneer MVH-150UBG Manual

19 September 2024
Pioneer

Pioneer CA-R-PI.161 Manual

18 September 2024
NovaStar

NovaStar MX20 Manual

18 September 2024
NovaStar

NovaStar MX30 Manual

18 September 2024
NovaStar

NovaStar MX40 Pro Manual

18 September 2024