APC SBP16KRMI4U Manual

APC Ikke kategoriseret SBP16KRMI4U

Læs nedenfor 📖 manual på dansk for APC SBP16KRMI4U (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 30 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
©2009 APC by Schneider Electric, APC, the APC logo, and Smart-UPS are
owned by Schneider Electric industries S.A.S American Power Conversion
Corporation, or their affiliated companies. All other trademarks are property
of their respective owners.
990-1530B
Note: Read the safety information sheet before installation.
Illustrations in this document may differ slightly from the actual hardware.
Attention: This product is for use in a controlled environment. Refer to product
specifications for environmental limits.
R MACK OUNTING
n
o Set SBP in the rack. If hardwiring is required, see Connecting Power
section before screwing into the rack.
W MALL OUNTING
n
o Whenever possible, attach one top screw and one bottom screw into a wall stud. If stud
mounting is not possible, use an expandable wall anchor. Screws are not included; .25” x
2” lag bolts are recommended.
T O ( SOWER PTION FOR MART-UPS RT SETUPS ONLY)
n Remove screw from the top and bottom rear of both the UPS and SBP. Install tie
brackets and reattach screws.
o Unscrew and remove top cover of the
UPS.
p Attach bracket to top of UPS and SBP.
q Reattach top cover of the UPS.
Note: The SBP5000RMI2U, when used in conjunction with an SURT3000XLI or SURT5000XLI UPS in a
tower configuration without an external battery pack (SURT192XLBP), is suitable for mounting on
concrete or other non-combustible smooth surfaces only.
U C SER ONFIGURABLE
Attention: When using an online UPS, put the UPS in automatic bypass mode before
rotating the SBP switch.
1. Normal: Power is directed from the utility outlet, through the Bypass Panel and UPS,
and to connected equipment. For use during normal UPS operation.
2. Test: Power supplied to the UPS is not output. Use when tests are being conducted on
the UPS, and connected equipment is not yet desired.
3. Bypass: Power from the utility outlet is filtered through the Bypass Panel, and to the
connected equipment. Use to bypass the UPS, when functioning improperly.
Note: While operating in ‘Test’ or ‘Bypass’ mode, power to the connected equipment is
not conditioned by the UPS. At this time, the “Equipment Protection Policy” is not valid.
I PDENTIFYING THE ANEL
Service Bypass Panels will differ. Refer to chart for unit specifications.
Note: HW= Hardwire
Service Bypass
Panel
Corresponding
UPS Systems
Bypass
Input
UPS
Input
UPS
Output
PDU
Panel
SBP3000RM2U 100-120V Smart-UPS
3kVA
L5-30P L5-30P L5-30R (2) 5-20R,
(6) 5-15R
SBP5000RMT2U 200/208/240V
Smart-UPS 3-4.5kVA
L6-30P L6-30P L6-30R (2) L6-20R,
(2) L6-30R
SBP5000RMI2U* 230V Smart-UPS
3-5kVA
C20/HW C19/HW C20/HW (2) C19,
(8) C13
SBP6KRMT2U** 200/208/240V
Symmetra 2-6kVA
L6-30P/
HW
L6-30R/
HW
L6-30P/
HW
(1) L6-20R,
(2) L6-30R
SBP6KRMI2U 230V Symmetra
2-6kVA
HW HW HW (4) C19
SBP3000 100-240V Smart-UPS
3-5kVA with 30A HW
input/output
available
HW HW HW HW
SBP10KRMT4U 200/208/240V
Smart-UPS RT
7.5-10kVA
HW HW HW (3) L6-20R,
(3) L6-30R
SBP10KRMI4U 230V Smart-UPS RT
7.5-10kVA
HW (3Ph
or 1Ph)
HW (3Ph
or 1Ph)
HW (8) C13,
(2) C19
SBP16KP 200-240V
Symmetra LX
4-16kVA
HW (3Ph
or 1Ph)
HW (3Ph
or 1Ph)
HW HW
SBP16KRMI4U 220-240V
Symmetra LX
4-16kVA
HW (3Ph
or 1Ph)
HW (3Ph
or 1Ph)
HW (3) 30A HW
SBP16KRMP4U 200/208/240
Symmetra LX
4-16kVA
HW HW HW (6) L14-30R
SBP16KRMP4U-HW 200/208/240
Symmetra LX
4-16kVA
HW HW HW (1) L14-30R,
(3) L5-20R,
(1) 100A HW
*For loads exceeding 3kVA, hardwiring is necessary.
**For loads exceeding 5kVA, hardwiring is necessary.
x4
x4
x4
x8
Rea
r
Front
x1
x4
x8
x2
x2
x2


Produkt Specifikationer

Mærke: APC
Kategori: Ikke kategoriseret
Model: SBP16KRMI4U
Vekselstrømsindgangsspænding: 230 V
Vekselstrømsindgangsfrekvens: 50 - 60 Hz
Bredde: 432 mm
Dybde: 673 mm
Højde: 178 mm
Vægt: 21820 g
Produktfarve: Sort
Produkttype: Bypass-afbryder
Pakkevægt: 31820 g
Pakkedybde: 991 mm
Pakkebredde: 610 mm
Pakkehøjde: 305 mm
Opbevaringstemperatur (T-T): -40 - 65 °C
Relativ luftfugtighed ved drift (H-H): 0 - 95 %
Relativ luftfugtighed ved opbevaring (H-H): 0 - 95 %
Driftstemperatur (T-T): -20 - 45 °C
Dimensioner (BxDxH): 432 x 673 x 178 mm
Certificering: CSA, EN 60950, GOST, IEC 60950, IEC 60950, UL 1778
Monteringstype: Reolbeslag
Harmoniseret systemkode (HS): 85079080
Bæredygtighedscertifikater: RoHS
Indgangsspænding: 230 V
Driftshøjde: 0 - 4500 m
Ikke-drift højde: 0 - 15000 m
Kompatible produkter: CSA, EN 60950, GOST, IEC 60950, IEC 60950, UL 1778
Indgangsfrekvens: 50/60 Hz
Kapabilitet: CSA, EN 60950, GOST, IEC 60950, IEC 60950, UL 1778
Total effekt: Hard Wire 3-wire W
Load-kapacitet: 20000 VA
Maksimal strømtræk pr. fase: 100 A
Rackkapacitet: 4U
Udgangsspænding note: (3) Hard Wire 3-wire (H N + G)
Strømstyring: Ja
Antal faser: 1

Har du brug for hjælp?

Hvis du har brug for hjælp til APC SBP16KRMI4U stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret APC Manualer

APC

APC FS-AC-8002-U Manual

15 Oktober 2024
APC

APC EVP1000 Manual

14 Oktober 2024
APC

APC E3SXR6 Manual

20 September 2024
APC

APC C2C Manual

17 September 2024
APC

APC AP7868 Manual

17 September 2024
APC

APC P8VNTG Manual

17 September 2024
APC

APC P62 Manual

17 September 2024
APC

APC AP7898 Manual

17 September 2024
APC

APC AP7811 Manual

17 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

SoundTube

SoundTube IPD-RS82-EZ Manual

26 November 2024
Kramer

Kramer 4x1VB Manual

26 November 2024
Kramer

Kramer RC-63A Manual

26 November 2024
SoundTube

SoundTube IPD-HP82-EZ Manual

26 November 2024
Kramer

Kramer RK-KVM-1U-PP3 Manual

26 November 2024
Gioteck

Gioteck VX-2 (PS3) Manual

26 November 2024
AOpen

AOpen DE3650-C Manual

26 November 2024
Lazer

Lazer Urbanize MIPS Manual

26 November 2024
Symmons

Symmons Dia 353GB-24 Manual

26 November 2024
SoundTube

SoundTube IPD-RS62-EZ Manual

26 November 2024