BEKO BSEOG 090 Manual

BEKO Aircondition BSEOG 090

Læs nedenfor 📖 manual på dansk for BEKO BSEOG 090 (60 sider) i kategorien Aircondition. Denne guide var nyttig for 15 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/60
Split type air conditioner
User Manual
EN
02M-8503573200-3322-02
BSEOG 090 / BSEOG 091
BSEOG 120 / BSEOG 121
BSEOG 180 / BSEOG 181
CONTENTS
ENGLISH 4-64
V2109001
Please read this user manual rst!
Dear Customer,
Thank you for preferring a Beko product. We hope that you get the best results
from your product which has been manufactured with high quality and state-of-
the-art technology. Therefore, please read this entire user manual and all other
accompanying documents carefully before using the product and keep it as a
reference for future use. If you handover the product to someone else, give the user
manual as well. Follow all warnings and information in the user manual.
Meanings of the symbols
Following symbols are used in the various section of this manual:
C
A
and property.
never perform.
B
read carefully.
manual.
(For R32/ R290 gas type)
exposed to an
This product has been manufactured at modern facilities respectful to the environment without harming nature.
Complies with the WEEE Regulation. Does not contain PCB.
CONTENTS
1 Safety precautions 6
2 Unit specifications and features 15
2.1 Indoor unit display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.2 Operating temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.3 Inverter split type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.4 Fixed-speed type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.5 Other features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
2.6 Manual operation (without remote) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3 Care and maintenance 21
3.1 Cleaning your indoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.2 Cleaning your air filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.3 Maintenance — long periods of non-use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.4 Maintenance – pre-season inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4 Troubleshooting 24
4.1 Common issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5 Accessories 28
6 Installation summary - indoor unit 30
7 Unit parts 31
8 Indoor unit installation 32
8.1 Installation instructions - Indoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
9 Outdoor unit installation 41
9.1 Installation instructions — outdoor unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
4 / EN Split type air conditioner / User Manual
CONTENTS
10 46
10.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
10.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
11 50
11.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
11.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
11.3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
12 52
12.1 Before test run. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
12.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
12.3 Gas leak checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
13 Test Run 54
13.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
14 55
15 56
15.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
16 57
5 / EN
6 / EN Split type air conditioner / User Manual
Warning
This appliance can be used by
children aged from 8 years and
above and persons with reduced
physical, sensory or mental
capabilities or lack of experience
and knowledge if they have
been given supervision or
instruction concerning use of
the appliance in a safe way
and understand the hazards
involved. Children shall not play
with the appliance. Cleaning
and user maintenance shall not
be made by children without
supervision (European Union
countries).
This appliance is not intended
for use by persons (including
children) with reduced physical,
sensory or mental capabilities,
or lack of experience and
knowledge, unless they have
been given supervision or
instruction concerning use
of the appliance by a person
responsible for their safety.
Children should be supervised
to ensure that they do not play
with the appliance.
Warnings for product
use
If an abnormal situation
arises (like a burning smell),
immediately turn off the unit
and disconnect the power. Call
your dealer for instructions
to avoid electric shock, fire or
injury.
Do not insert fingers, rods or
other objects into the air inlet
or outlet. This may cause injury,
since the fan may be rotating at
high speeds.
Do not use flammable sprays
such as hair spray, lacquer or
paint near the unit. This may
cause fire or combustion.
Do not operate the air
conditioner in places near or
around combustible gases.
1 Safety precautons
Split type air conditioner / User Manual 7 / EN
Emitted gas may collect around
the unit and cause explosion.
Do not operate your air
conditioner in a wet room
such as a bathroom or laundry
room. Too much exposure
to water can cause electrical
components to short circuit.
Do not expose your body
directly to cool air for a
prolonged period of time.
Do not allow children to
play with the air conditioner.
Children must be supervised
around the unit at all times.
If the air conditioner is used
together with burners or other
heating devices, thoroughly
ventilate the room to avoid
oxygen deficiency.
In certain functional
environments, such as
kitchens, server rooms, etc.,
the use of specially designed
air-conditioning units is highly
recommended.
Cleaning and
maintenance warnings
Turn off the device and
disconnect the power before
cleaning. Failure to do so can
cause electrical shock.
Do not clean the air conditioner
with excessive amounts of
water.
Do not clean the air conditioner
with combustible cleaning
agents. Combustible cleaning
agents can cause fire or
deformation.
Caution
Turn off the air conditioner and
disconnect the power if you are
not going to use it for a long
time.
Turn off and unplug the unit
during storms.
Make sure that water
condensation can drain
unhindered from the unit.
Do not operate the air
conditioner with wet hands.
1 Safety precautons
8 / EN Split type air conditioner / User Manual
This may cause electric shock.
Do not use device for any other
purpose than its intended use.
Do not climb onto or place
objects on top of the outdoor
unit.
Do not allow the air conditioner
to operate for long periods of
time with doors or windows
open, or if the humidity is very
high.
Electrical warnings
Only use the specified power
cord. If the power cord is
damaged, it must be replaced
by the manufacturer, its service
agent or similarly qualified
persons in order to avoid a
hazard.
Keep power plug clean.
Remove any dust or grime that
accumulates on or around the
plug. Dirty plugs can cause fire
or electric shock.
Do not pull power cord to
unplug unit. Hold the plug
firmly and pull it from the
outlet. Pulling directly on the
cord can damage it, which can
lead to fire or electric shock.
Do not modify the length of
the power supply cord or use
an extension cord to power the
unit.
Do not share the electrical
outlet with other appliances.
Improper or insufficient
power supply can cause fire or
electrical shock.
The product must be properly
grounded at the time of
installation, or electrical shock
may occur.
For all electrical work, follow
all local and national wiring
standards, regulations, and the
Installation Manual. Connect
cables tightly, and clamp them
securely to prevent external
forces from damaging the
terminal. Improper electrical
connections can overheat and
1 Safety precautons
Split type air conditioner / User Manual 9 / EN
cause fire, and may also cause
shock. All electrical connections
must be made according to the
Electrical connection diagram
located on the panels of the
indoor and outdoor units.
All wiring must be properly
arranged to ensure that the
control board cover can close
properly. If the control board
cover is not closed properly, it
can lead to corrosion and cause
the connection points on the
terminal to heat up, catch fire,
or cause electrical shock.
If connecting power to
fixed wiring, an all-pole
disconnection device which
has at least 3mm clearances
in all poles, and have a
leakage current that may
exceed 10mA, the residual
current device (RCD) having
a rated residual operating
current not exceeding 30mA,
and disconnection must be
incorporated in the fixed wiring
in accordance with the wiring
rules.
Take note of fuse
specications
The air conditioner’s circuit
board (PCB) is designed with
a fuse to provide overcurrent
protection. The specifications
of the fuse are printed on the
circuit board ,such as:
T3.15AL/250VAC,
T5AL/250VAC, T3.15A/250VAC,
T5A/250VAC, T20A/250VAC,
T30A/250VAC,etc.
C
Note: For the units
using R32 or R290
refrigerant , only the
blast-proof ceramic
fuse can be used.
1 Safety precautons
10 / EN Split type air conditioner / User Manual
HygieneMax(UV-C lamp)
(Applicable to the unit
contains HygieneMax
feature only)
This appliance contains a
HygieneMax(UV-C lamp). Please
read the following instructions
before opening the appliance.
1. Do not operate
HygieneMax(UV-C lamp)
outside of the appliance.
2. Appliances that are obviously
damaged must not be
operated.
3. Unintended use of the
appliance or damage to the
housing may result in the
escape of dangerous UV-C
radiation. UV-C radiation may,
even in small doses, cause
harm to the eyes and skin.
4. The appliance must be
disconnected from the supply
mains before cleaning your
unit or any other maintenance.
5. UV-C barriers bearing the
ultraviolet radiation hazard
symbol should not be removed.
A
Warnng: This
appliance contains
an UV emitter. Do
not stare at the light
source.
Warnings for product
installation
1. Installation must be performed
by an authorized dealer
or specialist. Defective
installation can cause water
leakage, electrical shock, or
fire.
2. Installation must be performed
according to the installation
instructions. Improper
installation can cause water
leakage, electrical shock, or
fire.
1 Safety precautons
Split type air conditioner / User Manual 11 / EN
3. Contact an authorized service
technician for repair or
maintenance of this unit. This
appliance shall be installed
in accordance with national
wiring regulations.
4. Only use the included
accessories, parts, and
specified parts for installation.
Using non-standard parts can
cause water leakage, electrical
shock, fire, and can cause the
unit to fail.
5. Install the unit in a firm location
that can support the unit’s
weight. If the chosen location
cannot support the unit’s
weight, or the installation is
not done properly, the unit
may drop and cause serious
injury and damage.
6. Install drainage piping
according to the instructions in
this manual. Improper drainage
may cause water damage to
your home and property.
7. For units that have an auxiliary
electric heater, install do not
the unit within 1 meter (3 feet)
of any combustible materials.
8. Do not install the unit in a
location that may be exposed
to combustible gas leaks. If
combustible gas accumulates
around the unit, it may cause
fire.
9. Do not turn on the power until
all work has been completed.
10. When moving or relocating
the air conditioner, consult
experienced service
technicians for disconnection
and reinstallation of the unit.
11. How to install the appliance
to its support, please read
the information for details in
“indoor unit installation” and
“outdoor unit installation
sections.
1 Safety precautions
12 / EN Split type air conditioner / User Manual
Note about uorinated
gasses (Not applicable
to the unit using R290
Refrigerant)
1. This air-conditioning
unit contains fluorinated
greenhouse gasses. For
specific information on the
type of gas and the amount,
please refer to the relevant
label on the unit itself or
the “User Manual - Product
Fiche“ in the packaging of the
outdoor unit. (European Union
products only).
2. Installation, service,
maintenance and repair of this
unit must be performed by a
certified technician.
3. Product uninstallation and
recycling must be performed
by a certified technician.
4. For equipment that contains
fluorinated greenhouse gases
in quantities of 5 tonnes of
CO2 equivalent or more, but
of less than 50 tonnes of
CO2 equivalent, If the system
has a leak-detection system
installed, it must be checked
for leaks at least every
24 months.
5. When the unit is checked for
leaks, proper record-keeping
of all checks is strongly
recommended.
Warning for Using R32/
R290 Refrigerant
When flammable refrigerant
are employed, appliance shall
be stored in a well -ventilated
area where the room size
corresponds to the room area
as specifiec for operation.
For R32 frigerant models:
Appliance shall be installed,
operated and stored in a room
with a floor area larger than
4m2.
For R290 refrigerant models,
appliance shall be installed,
operated and stored in a room
with a floor area larger than:
1 Safety precautons
Split type air conditioner / User Manual 13 / EN
<=9000Btu/h units: 13m2
>9000Btu/h and
<=12000Btu/h units: 17m2
>12000Btu/h and
<=18000Btu/h units: 26m2
>18000Btu/h and
<=24000Btu/h units: 35m2
Reusable mechanical
connectors and flared joints are
not allowed indoors.
(EN Standard Requirements).
Mechanical connectors used
indoors shall have a rate of
not more than 3g/year at 25%
of the maximum allowable
pressure. When mechanical
connectors are reused indoors,
sealing parts shall be renewed.
When flared joints are reused
indoors, the flare part shall be
re-fabricated. ( Standard UL
Requirements)
When mechanical connectors
are reused indoors, sealing
parts shall be renewed.
When flared joints are reused
indoors, the flare part shall be
re-fabricated. ( Standard IEC
Requirements)
Mechanical connectors used
indoors shall comply with
ISO 14903.
European disposal
guidelines
This marking shown on the
product or its literature,
indicates that waste electrical
and eletrical equipment should
not be mixed with general
household waste.
Correct dsposal
of ths product
(Waste electrcal
& Electronc
equpment)
This appliance contains
refrigerant and other potentially
hazardous materials. When
disposing of this appliance, the
law requires special collection
and treatment. dispose Do not
of this product as household
waste or unsorted municipal
waste.
1 Safety precautons
14 / EN Split type air conditioner / User Manual
When disposing of this
appliance, you have the
following options:
Dispose of the appliance at
designated municipal electronic
waste collection facility.
When buying a new appliance,
the retailer will take back the
old appliance free of charge.
The manufacturer will take
back the old appliance free of
charge. (for some countries)
Sell the appliance to certified
scrap metal dealers. (for some
countries)
C
Special notice:
Disposing of this
appliance in the
forest or other
natural surroundings
endangers your
health and is bad for
the environment.
Hazardous substances
may leak into the
ground water and
enter the food chain.
1 Safety precautions
Split type air conditioner / User Manual 15 / EN
2.1 Indoor unit display
C
Note: Different models have different front panels and display windows. Not all the
display codes describing below are available for the air conditioner you purchased.
Please check the indoor display window of the unit you purchased.
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be
slightly different. The actual shape shall prevail.
(A) (B)
Front panel
Louver
Power cable (some units)
Remote control Remote control holder
(some units)
Display window
“fresh“ when Fresh or HygieneMax (if any) feature is activated (some units)
“defrost when defrost feature is activated.
“run“ when the unit is on.
“timer“ when TIMER is set.
“ “ when Wireless Control feature is activated (some units)
“ “ Displays temperature, operation feature and error codes:
“ for 3 seconds when:
TIMER ON is set (if the unit is OFF, “ “ remains on when TIMER
ON is set)
FRESH, HygieneMax, SWING, TURBO, ECO, or SILENCE feature is turned on “
“ for 3 seconds when:
TIMER OFF is set
FRESH, HygieneMax, SWING, TURBO, ECO, or SILENCE feature is turned off
“ when defrosting
“ when 8°C heating feature is turned on (some units)
when Go Clean or Self Clean+ feature is turned on (depends on model)
fresh defrost run timer
Functional filter
(On back of main filter - some units)
Display Code
Meanings
2 Unit specifications and features
16 / EN Split type air conditioner / User Manual
2.2 Operating temperature
When your air conditioner is used outside of the
following temperature ranges, certain safety
protection features may activate and cause the
unit to disable.
2.3 Inverter split type
COOL mode HEAT mode DRY mode
Room
Temperature
16°C - 32°C
(60°F - 90°F)
0°C - 30°C
(32°F - 86°F)
10°C - 32°C
(50°F - 90°F)
Outdoor
Temperature
0°C - 50°C (32°F - 122°F) -15°C - 24°C
(5°F - 75°F)
for some model
-20°C - 24°C
(-4°F - 75°F)
0°C - 50°C
(32°F - 122°F)
-15°C - 50°C (5°F - 122°F)
(For models with low temp.
cooling systems.)
0°C - 52°C (32°F - 126°F)
(For special tropical models)
0°C - 52°C
(32°F - 126°F)
(For special tropical
models)
For outdoor units with auxiliary electric
heater
When outside temperature is below 0°C (32°F),
we strongly recommend keeping the unit
plugged in at all time to ensure smooth ongoing
performance.
2.4 Fixed-speed type
COOL mode HEAT mode DRY mode
Room
Temperature 16°C-32°C (60°F-90°F) 0°C-30°C
(32°F-86°F) 10°C-32°C (50°F-90°F)
Outdoor
Temperature
18°C-43°C (64°F-109°F)
-7°C-24°C
(19°F-75°F)
11°C-43°C (52°F-109°F)
-7°C-43°C (19°F- 109°F)
(For models with low-temp cooling
systems)
18°C-43°C (64°F-109°F)
18°C-52°C (64°F -126°F)
(For special tropical models)
18°C-52°C (64°F- 126°F)
(For special tropical models)
2 Unit specifications and features


Produkt Specifikationer

Mærke: BEKO
Kategori: Aircondition
Model: BSEOG 090

Har du brug for hjælp?

Hvis du har brug for hjælp til BEKO BSEOG 090 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Aircondition BEKO Manualer

BEKO

BEKO BEPB12H Manual

12 Januar 2025
BEKO

BEKO BIHPR 120 Manual

11 Januar 2025
BEKO

BEKO EFE6030W Manual

30 December 2025
BEKO

BEKO BRH 246 Manual

27 August 2024
BEKO

BEKO BPVOW 120 Manual

27 August 2024
BEKO

BEKO BPVOW 090 Manual

27 August 2024
BEKO

BEKO BRH 076 Manual

27 August 2024
BEKO

BEKO BRH 245 Manual

27 August 2024
BEKO

BEKO BRH 075 Manual

27 August 2024

Aircondition Manualer

Nyeste Aircondition Manualer

Daitsu

Daitsu AUD-30K-DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 36K DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 48K DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 60TK DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 42K DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 48TK DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 36TK DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 18K DB Manual

28 Februar 2025
Daitsu

Daitsu AUD 24K DB Manual

28 Februar 2025