Beverage-Air MMR27HC-1-B Manual

Beverage-Air Køleskab MMR27HC-1-B

Læs nedenfor 📖 manual på dansk for Beverage-Air MMR27HC-1-B (29 sider) i kategorien Køleskab. Denne guide var nyttig for 20 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/29
INSTALLATION AND OPERATING INSTRUCTIONS
for all Hydrocarbon
MMR Refrigerator Models
3779 CHAMPION BLVD, WINSTON-SALEM, NC 27105
Phone: (888) 845-9800 | Fax: (800) 253-5168 | Web: beverage-air.com
809-150A 04/06/2022 SEE BACK COVER FOR
WARRANTY REGISTRATION
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22Beverage-Air4
CAUTION: If it is necessary to move the Refrigerator after removal from the skid,
remove all doors and carefully push the unit at a point of no more than 36” from the
bottom to avoid damage.
CAUTION
Push ONLY below the 36 inch / .91 meter height
Height
will vary
by model
Do NOT push in this area.
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22 Beverage-Air 5
IMPORTANT INFORMATION
This unit is intended to be used in a commercial application. That includes bars and restaurants.
If installed in a residence some commercial service companies may not be able to service it on site.
The manufacturer has designed and produced this machine with the nest in materials. The manufacturer assumes no
liability for units that have been altered in any way. Alterations or part substitutions will void the warranty.
Limitations
The machine is designed for use indoors in a controlled
environment. It must be kept dry, not overheated or
subjected to excessive cold. May only be connected to
a dedicated electrical circuit. Extension cords are not
permitted.
Minimum Maximum
Voltage 103.5 126.5
Room Air Temp 60º F 100º F
Air Flow, All Models regardles of section, door count or door material.
Agency Approvals
These marks appear on the dataplate or serial tag, located
in the inside of the left wall. The dataplate also contains
the model and serial numbers as well as electrical
requirements.
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22Beverage-Air6
Model Cabinet Dimensions
w x d x h (Inches)
Half or
Full Door
Glass or
Solid Door
Full Load
Amps
Power Cord
Plug (NEMA)
Refrigerant Type /
Charge (g)
MMR12HC-1 24 1/8 x 25 3/4 x 62 Full Glass 2 5-15P R-290 / 75*
MMR23HC-1 27 x 33 5/8 x 78 Full Glass 3 5-15P R-290 / 80*
MMR27HC-1 30 x 33 5/8 x 78 Full Glass 3 5-15P R-290 / 80*
MMR38HC-1 43 1/2 x 32 1/4 x 78 Full Sliding Glass 5-15P R-290 / 115*5.4
MMR44HC-1 47 x 33 1/2 x 78 Full 2 Glass 5-15P R-290 / 115*5.4
MMR45HC-1 52 x 32 1/4 x 78 Full Sliding Glass 5-15P R-290 / 115*5.4
MMR49HC-1 52 x 33 1/4 x 78 Full 2 Glass 5-15P R-290 / 115**5.4
MMR66HC-1 75 x 32 1/8 x 78 Full Sliding Glass 6.2 5-15P R-290 / 150**
MMR72HC-1 75 x 33 1/2 x 78 Full 3 Glass 6.2 5-15P R-290 / 150**
MMR12HC-IQ 24 1/8 X 25 3/4 X 62 Full Glass 2 5-15P R-290 / 75*
MMR23HC-IQ 27 x 33 5/8 x 78 Full Glass 3 5-15P R-290 / 80*
MMR27HC-IQ 30 x 33 5/8 x 78 Full Glass 3 5-15P R-290 / 80*
MMR44HC-IQ 47 x 33 5/8 x 78 Full 2 Glass 5-15P R-290 / 115*5.4
MMR49HC-IQ 52 x 33 5/8 x 78 Full 2 Glass 5-15P R-290 / 115*5.4
MMR23HC-1-B-WINE 27 X 33 5/8 X 78 Full Glass 3 5-15P R-290 / 80*
MMR27HC-1-B-WINE 30 X 33 5/8 X 78 Full Glass 3 5-15P R-290 / 80*
MMR44HC-1-B-WINE 47 X 33 5/8 X 78 Full Glass 5-15P R-290 / 115*5.4
MMR49HC-1-B-WINE 52 X 33 5/8 X 78 Full 2 Glass 5-15P R-290 / 115*5.4
MMR72HC-1-B-WINE 75 X 33 5/8 X 78 Full 2 Glass 6.2 5-15P R-290 / 150*
Height includes casters.
PRODUCT INFORMATION
Standard refrigerator models will maintain product temperature between 35.5 and 40.5 degrees F. at the factory
setting of 38.0F.
Wine models will maintain product temperature between 35 and 62 degrees F. at the factory setting of 38.
0F.
All models are 115 volts, 60 Hz AC.
ALWAYS REFERENCE YOUR EQUIPMENT DATA PLATE AMPS, REFRIGERANT AND REFRIGERANT CHARGE FOR THE
MOST UP TO DATE AND ACCURATE VALUES.
There are no access valves on the refrigeration system.
*75 grams = 2.65 ounces
*80 grams = 2.82 ounces
*115 grams = 4.05 ounces
**150 grams = 5.3 ounces
Black, white or stainless models available in most cabinet sizes. Some have lock features available.
Low E glass available on some models
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22 Beverage-Air 7
CLEARANCE AND PLACEMENT
Placement
Consider the following when selecting a location for your Refrigerator:
Clearance:
6 in. at the top
3.0 in. at the rear,
0 in. at the left side
0 in. at the right side
0 in at the bottom
Floor Load: the oor on which the Refrigerator is located must be even and level, free from vibrations, and strong enough
to support the combined weights of the unit and maximum product load.
Ventilation: Grille area at front must be free and clear of any object or wall.
Power Outlet: Dedicated power outlet is located within the length of the unit's power cord.
6"
TOP
MINIMUM
CLEARANCE
0"
LEFT/RIGHT SIDE
MINIMUM
CLEARANCE
0"
BOTTOM
MINIMUM
CLEARANCE
3"
REAR
MINIMUM
CLEARANCE
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22Beverage-Air8
UNPACKING AND SET UP
CAUTION
Carefully inspect the shipping carton for damage. This is the only time that shipping damage may be claimed. If damage is
suspected, open the carton immediately and, if there is damage, retain the carton and contact the shipper to make a claim.
Do NOT contact the manufacturer.
Uncrating
Tools Needed: ¾” box wrench, adjustable wrench, level,
at head screw driver, and box cutter.
1. Cut the stretch wrap along a corner post and remove
the cardboard top capping and the corner posts.
2. Discard stretch wrap and any cardboard that will not
be recycled.
Note: additional clear plastic protective wrap is
applied directly to any product with a glass door.
3. Move unit as close to nal position as possible before
removing the skid.
Note: The skid must be removed before the casters or
legs can be attached.
Do NOT tip unit on its front or sides. If tipped onto the
back, unit must not be started for 3 hours.
Skid Removal and Caster Attachment
Tip the unit forward and remove the skid.
Risk of personal injury.
Unit must be securely supported
while attaching casters or legs.
WARNING
1. Remove the shipping bolts using the ¾” box wrench
while cabinet is held in one direction. Repeat the process
while the cabinet is held in the opposite direction.
2. None of the threads on the leg or caster stem should
be visible once screwed in.
3. Tilt the cabinet in one direction approximately 8” and
block it securely with pieces of 2x4 lumber or other
suitable material.
4. Thread the stem casters or legs into the ½ -13 holes in
the bottom of the cabinet. Tighten by hand as much
as possible.
5. Once the caster or leg cannot be turned any further,
use a 3/4 inch wrench to tighten the nut in between
the mounting plate and the wheel of the caster until
snug.
6. Repeat this procedure with unit secured in the
opposite direction so as to access the remaining legs/
casters
7. If plate casters or legs are installed instead of stem
casters or legs, then repeat step 3 above and secure
the plate with either #14 AB screws, or ¼-20 screws,
depending upon which are required.
Leveling:
Cabinets must be leveled when installed. Level should be
measured on the headrail.
Note: If no casters, legs or levelers are to be installed,
the oor below the equipment must be level
Failure to level your cabinet may result in door not
sealing, closing correctly, or condensed water draining not
draining properly.
For cabinets with legs, rotate the foot of the leg with an
adjustable wrench to achieve desired height for leveling.
For cabinets with casters, leveling can be achieved by
placing large washers in between the ½’ stud and the
holes located on the bottom of the case.
Do NOT loosen casters to level the cabinet. Casters MUST
be tightly secured to cabinet for full strength.
Install or attach any accessories
that will be used
Remove any plastic covering the
stainless steel.
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22 Beverage-Air 9
1. Determine the proper location for the shelf clips.
The reference numbers on the pilaster can serve as a
guide to ensure all clips are properly located.
2. Insert the top tab of the shelf clip into the desired
hole of the pilaster. The retaining tab MUST be facing
up as shown.
3. Rotate the clip downwards and insert the bottom tab
into the matching hole in the pilaster. The clip may
need to be squeezed slightly during installation.
4. Install all remaining clips.
5. Install shelves onto clips with the product retention
bar facing up. Be careful not to dislodge clips during
installation.
6. Place shelves so that the retaining tab on the clip
captures the shelf as shown.
7. Conrm that the shelf is resting on ALL 4 clips and
that the clips are securely attached to the pilasters.
8. Improper shelf clip installation could cause the shelf
and / or the product on it to fall, resulting in damage
to the unit and possible bodily injury.
9. Do NOT overload the shelves. The unit is designed to
use all shelves that are supplied in an equally spaced
manner. Contact Beverage-Air customer service if
fewer shelves or a dierent conguration to ensure
shelf overloading will not occur.
SHELF INSTALLATION
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22Beverage-Air10
SLIDING GLASS DOORS
1
Adjusting Spring Tension on ClearCool®3000 & ClearCool®3100
The amount of tension used on the self- d closing bottle slider doors can be decrease or increased by relocating the spring
retaining grommet and self drilling screw.-
1. Hold door in open position to expose spring, grommet and screw in the header. Open only as far as required to keep
the amount of tension to a minimum.
2. Look into Header and n 3 square cut outs.ote the
1. Inner location is for minimum tension.
2. M - id location is for mid range tension.
3. Outside location is for maximum tension.
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22 Beverage-Air 11
This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the
machine to conrm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.
Note: Do not connect to GFI / GFCI outlets. Connection to that type of outlet can result in product loss due to
unsafe cabinet temperature when GFI device trips from moisture.
Power Cord
This 115 volt model is equipped with a cord and 5-15P plug.
If the power cord becomes damaged, it must be replaced
with the identical cord.
Follow All National and Local Codes
This Unit Must Be Grounded. Do not use extension cords
and do not disable or by-pass ground prong on electrical
plug.
Initial Start Up
Plug the power cord into the proper power supply.
The cabinet will soon begin to blow warm air out of the
top area, and cool air will ow from the inside blower.
The cabinet temperature has been set at the factory and
should not need adjustment, however if it was changed,
the standard setting is 38º F.
Cautions
Care must be taken whenever moving or servicing the
unit. The refrigerant is contained in a sealed system, but if
released it may be ammable.
Door Reversal Instructions
1. Remove hinge cover.
2. Remove door from the unit including the hinge
mounting brackets
3. Remove white hole covers from the side of the door
opening you would like the hinges to be located (do
not throw away).
4. On the bottom of the door the same hole plugs are
present and need to be removed.
5. Take the hole plugs and insert them into the screw
holes where the hinges were originally located on the
unit.
6. Install the hinge bracket upright on the unit. The
thick portion of the hinge bracket should be on the
bottom as you mount them.
7. The door portion of the hinges need to be removed
and rotated 180 degree and remounted.
8. Install the hole plugs that were removed from the
bottom of the door into the holes where the handle
was rst mounted.
9. Slide door back into position and gently lower into the
white pivot cam.
10. Replace hinge cover.
ELECTRICAL
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22 Beverage-Air 13
SEQUENCE OF OPERATIONS REFRIGERATOR
The refrigerator operates based on the air temperature measured by the probe located at the return air.
ON OFF
COMPONENT OPERATION CONTROLLER ACTION OPERATION CONTROLLER ACTION
COMPRESSOR
Compressor turns
on when the air
temperature at the
probe is above the
sum of the set point
+2
The Compressor
Contact is energized
Compressor turns
o when the air
temperature at probe is
equal to or less than the
set point -2
The Compressor
Contact is de-
energized
(ERC 112 – Terminal #1) (ERC 112 – Terminal
#1)
CONDENSER FAN
The Condenser Fan
turns on when
the Compressor is
running
The Condenser Fan
is wired directly to
the Compressor, not
through the controller
The Condenser Fan
turns o when the
Compressor is not
running
The Condenser Fan
is wired directly to
the Compressor, not
through the controller
EVAPORATOR
FAN
The Evaporator Fan
runs continuously in
refrigerators. When
the unit is plugged
in, the Evaporator
Fan will run.
The Evaporator Fan is
connected directly to
incoming power, not
through the controller.
The Evaporator Fan runs
continuously. When the
unit is plugged in, The
Evaporator Fan will run.
The Evaporator Fan is
connected directly to
incoming power, not
through the controller.
LIGHT
The light will turn on
when the is
pressed (or when the
door is opened with
solid doors)
The Light Contact is
energized
The light will turn o
when the is
pressed (or when the
door is closed with solid
doors)
The Light Contact is
de-energized
(ERC 112 – Terminal
#4)
(ERC 112 – Terminal
#4)
Condition
Compressor
Condenser Fan
Evaporator
Fan
Lights
Cabinet Temp > Set point + 2 ON ON ON ON or OFF
Cabinet Temperature <= Set point - 2 OFF OFF ON ON or OFF
Defrost OFF OFF ON ON or OFF
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22Beverage-Air14
Electronic Controller
Control Panel Display
Defrost LED Alarm LED
On xed: Defrost active On xed: ALARM Present
O: Defrost is o Flashing: ALARM Silenced
O: No Alarm
Fan LED Compressor LED
On xed: Fan active On xed: Compressor active
O: Fan O Flashing: Delay, protection or activation blocked
O: No Alarm
Keyboard Functions
UP
Quick press and release
Increases Set Point
Long press and release
Increases display brightness
DOWN
Quick press and release
Decreases Set Point
Long press and release
Decreases display brightness
DEFROST (ESC)
Quick press and release
Activates manual defrost
Long press and release
Controller enter stand-by mode
SET (ENTER)
Quick press and release
Toggles lights on/o
Long press and release
Toggles display °F/°C
NOTE: When switched on, the instrument panel performs a lamp test for a few seconds.
UP
DOWN
DEFROST (ESC)
SELECT (OK)
Note: When the controller is in a Standby Mode, a
blue dot will be displayed as shown here. To switch
out of Standby Mode, push and hold the Defrost
button until the display reads ON.
.
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22 Beverage-Air 15
Control Panel Connections
Changing the Set point
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22Beverage-Air16
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22 Beverage-Air 17
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22Beverage-Air18
SEQUENCE OF OPERATIONS REFRIGERATOR
The refrigerator operates based on the air temperature measured by the probe located at the return air.
ON OFF
COMPONENT OPERATION CONTROLLER
ACTION OPERATION CONTROLLER
ACTION
COMPRESSOR
Compressor turns on
when the air
temperature at the
probe is above the
sum of the set point
+ 4
The Compressor Contact
is energized
Compressor turns
off when the air
temperature at
probe is equal to
or less than the
set point
The Compressor Contact
is de-energized
(EW+978 - Terminal
#1)
(EW+978 - Terminal #1)
CONDENSER FAN
The Condenser
Fan turns on when
the Compressor is
running
The Condenser Fan is
wired directly to the
Compressor, not throu
g
h
the controller
The Condenser Fan
turns off when the
Compressor is not
running
The Condenser Fan is
wired directly to the
Compressor, not throu
g
h
the controller
EVAP FAN
The Evaporator
Fan turns on when
the unit is
powered on.
The Evaporator Fan is
wired to constant power
The Evaporator Fan
turns off when the
unit is unplugged
or put into standby.
The Evaporator Fan is
wired to constant power
Some models will be
wired to the fan relay
(EW+978 - Terminal
#3)
Some models will be
wired to the fan relay
(EW+978 - Terminal
#3)
LIGHT
The light will turn on
when the down
button is
pressed (or when the
door is opened with
solid doors)
The Light Contact is
energized The light will turn
off when the down
button is
pressed (or when the
door is closed with
solid doors)
The Light Contact is de-
energized
(Ew+978 Terminal #2) (Ew+978 Terminal #2)
Condition
Compressor
Condenser
Fan
Evaporator
Fan
Lights
Cabinet Temp > Set point + 4 ON ON ON ON or OFF
Cabinet Temperature <= Set point - 4 OFF OFF ON ON or OFF
Defrost OFF OFF ON ON or OFF
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22 Beverage-Air 19
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22 Beverage-Air 21
CLEANING AND MAINTENANCE
Cleaning Schedule:
Cabinet
Daily wipe down
Weekly interior
Condenser coil
Quarterly cleaning
Gaskets
Daily inspection, check
that hinges are tight to
the cabinet.
Routine maintenance
Annually
Daily Exterior Cleaning
It is much easier to clean on a regular basis than to have to remove stains once they have built up.
1. Wash with a clean sponge and a mild detergent that
does not contain chlorine.
2. Rinse with clean water.
3. Dry with a soft cloth.
4. Polish with a soft cloth, wiping with the grain.
5. Wipe weekly with stainless steel cleaner.
Weekly Interior Cleaning
1. Remove all food, food related items and shelves. Store
the food at a safe temperature.
2. Disconnect power to the unit (unplug it or switch the
breaker o).
3. Remove all loose food particles from the inside walls,
oor, door liner and ceiling.
4. Scrub all interior surfaces and door gaskets with a
warm (100oF to 110oF) detergent solution and a soft
scrub brush.
5. Rinse with clean water and allow to air dry.
6. Return the shelves to the unit and secure them.
7. Restore power.
8. Return food to the unit when it has reached a safe
temperature.
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22 Beverage-Air 23
Cleaning Needed Cleaning Agent Method of Application Aect on Finish
Smears and ngerprints
Areal 20, Lac-O-Nu, Lumin Wash
O’Cedar Cream Polish, Stainless
Shine.
Rub with cloth as directed
on the package.
Satisfactory for use on all
nishes.
Provides barrier lm to
minimize prints.
Stubborn Spots and
Stains, Baked-On
Splatter, and Other
Light Discolorations
Allchem Concentrated Cleaner.
Apply with damp sponge or
cloth.
Rub with damp cloth.
Use in direction of polish lines
on No. 4 (polished) nish. May
scratch No.
2 (mill) and Nos. 7 and 8
(polished) nishes.
Samae, Twinkle or Cameo Copper
Cleaner Rub with damp cloth.
Grade FFF Italian pumice, whiting,
or talc. Rub with dry cloth.
Liquid NuSteel
Paste NuSteel or DuBois Temp.
Copper’s Stainless Steel Cleaner
Revere Stainless Cleaner
Household cleansers, such as
Old Dutch, Lighthouse, Sunbrite,
Wyandotte, Bab-O, Gold Dust,
Sapolio, Bon Ami, Ajax, or Comet
Grade F Italian Pumice, Steel
Bright, Lumin Cleaner, Zud,
Restore, Sta-Clean, or Highlite.
Penny-Brite or Copper-Brite.
Use small amount of cleaner.
Rub with dry cloth using a
small amount of cleaner.
Apply with damp sponge or
cloth.
Rub with a damp cloth. May
contain chlorine bleaches.
Rinse
thoroughly after use.
Rub with a damp cloth.
Rub with a dry cloth using a
small amount of cleaner.
Heat tint or
discoloration
Penny-Brite or Copper-Brite.
Past NuSteel, DuBois Temp,
or Tarnite. Revere Stainless Steel
Cleaner. Allen Polish, Steel Bright,
Tenacious Deposits,
Rusty Discolorations,
Industrial
Atmospheric Stains Wyandotte,
Bab-O or Zud.
Rub with a dry cloth.
Rub with a dry cloth or stain-
less steel wool.
Apply with damp sponge or
cloth.
Rub with a damp cloth.
Burnt-On Foods and
Grease Fatty Acids,
Milkstone (where
swabbing or rubbing
is not practical)
Easy-O, De-Grease-It, 4 to 6%
hot solution of such agents as
trisodium phosphate or sodium
tripolyphosphate or 5 to 15% caustic
soda solution
Apply generous coating. Allow
to stand for 10-15 minutes.
Rinse.
Repeated application may be
necessary.
Excellent removal, satisfactory
for use on all nishes.
Tenacious Deposits,
Rusty Discolorations,
Industrial
Atmospheric Stains
Oakite No. 33, Dilac Texo 12, Texo NY,
Flash-Klenz, Caddy Cleaner,
Turco Scale 4368 or Permag 57.
Swab and soak with clean
cloth.
Let stand 15 minutes or more
according to directions on
package, then rinse and dry.
Satisfactory for use on all
nishes
Hard Water Spots
and Scale
Vinegar.
5% oxalic acid, 5% sulfamic acid, 5 to
10% phosphoric acid, or Dilac, Oakite
No. 33, Texo 12, Texo N.Y.
Swab or wipe with cloth. Rinse
with water and dry.
Swab or soak with cloth. Let
stand 10-15 minutes. Always
follow with neutralizer rinse,
and dry.
Satisfactory for all nishes.
Satisfactory for all nishes.
Eective on tenacious deposits
or where scale
has built up.
METHODS FOR CLEANING STAINLESS STEEL
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22Beverage-Air24
HELP
Trouble Diagnosis for the User
Malfunction Possible Cause Likely Solution
No cooling - unit is silent
Unit not plugged in.
Fuse or circuit breaker tripped.
Power cord plug loose in outlet.
Connect to proper voltage circuit Replace
fuse or reset breaker.
Check outlet for loose connection, replace
as needed
Unit cools but seems to be on all the time Dirty condenser Clean condenser
Space temperature too high
Dirty condenser
Evaporator iced over Unit in high
temperature environment
Clean condenser Defrost evaporator
Reduce temperature of room
Space temperature too low Temperature control Adjust or replace control
Trouble Diagnosis for the Technician
No cooling - compressor does not hum Temp control stuck in open position Replace temp control.
No cooling - compressor hums but does not
start
Low voltage to unit.
Compressor starting system failure
Check voltage, correct as needed. Check
start relay and start capacitor. See next
step.
No cooling - compressor starts but shuts
o
Compressor start relay failure Compressor
start capacitor failure Replace relay. Replace capacitor.
No cooling - compressor cycles on and o Overheating weak overload
Clean condenser, check fan motor and
blade. Check refrigerant charge. Replace
overload.
Unit cools, but is slow to pull cabinet
temperature down Evaporator fan not turning
Check fan(s), on multiple fan units one fan
may be turning slowly and will need to be
replaced.
Unit cools but turns on and o frequently No product in cabinet. Temperature control
defective Refrigeration issue
Fill cabinet Replace control
Have system checked
Makes excessive noise
Tubing rattle Loose parts
Bent or broken fan blade Noisy fan motor
Check tubing for routing Check for loose
components Replace fan blade
Replace fan motor
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22 Beverage-Air 25
FOR THE SERVICE TECH - R290
Refrigeration service should only be attempted by a trained trade professional certied to work on R290 systems.
Here are some critical service items.
This list does not qualify anyone to service the unit. It is a
reminder and checklist for the service tech. Keep these in
mind for :R290 service
Wire nuts are NOT to be used when changing an
electrical part.
The switches in this product are sealed, only exact
replacements may be used.
The process tubes are to be used for service access.
Cut out (with tubing cutter) refrigeration components
that are to be replaced. Do NOT un-braze.
Because R290 can be vented into the air during
service, the venting MUST be in an area free from
ame or spark. It must be near an opened window or
door.
A sign noting service of a system containing propane
must be attached to the unit during refrigeration
service.
A combustible gas leak detector must be used to
inform anyone in the area when propane is present in
the air.
Other Information:
Evacuation: It is critical that a refrigeration system be
leak free and internally dry. A thorough evacuation with
a good vacuum pump with a micron gauge attached is the
only way to ensure that the system is dry and ready for a
charge of refrigerant.
Charging: The system is critically charged and the proper
type and amount MUST be weighed in.
Overcharge symptoms: Unit will cool properly but
the suction line temperature will be unusually cold.
Compressor run time will be longer than normal.
Undercharge symptoms: Long run time, poor cooling and
a hot compressor dome are the main symptoms of an
undercharge.
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22Beverage-Air26
FOR THE SERVICE TECH - WIRING DIAGRAM - DANFOSS
User Manual for MMR Refrigerators Beverage-Air
Rev. 04/22Beverage-Air28
MMR12HC-IQ
MMR23HC-IQ
MMR27HC-IQ
MMR44HC-IQ
MMR49HC-IQ


Produkt Specifikationer

Mærke: Beverage-Air
Kategori: Køleskab
Model: MMR27HC-1-B

Har du brug for hjælp?

Hvis du har brug for hjælp til Beverage-Air MMR27HC-1-B stil et spørgsmål nedenfor, og andre brugere vil svare dig




Køleskab Beverage-Air Manualer

Køleskab Manualer

Nyeste Køleskab Manualer