Blaupunkt DC-S3 Manual


Læs nedenfor 📖 manual på dansk for Blaupunkt DC-S3 (2 sider) i kategorien Overvågningskamera. Denne guide var nyttig for 20 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Door/Window and Shutter Detector with Wire Input (DC-S3)
P
Pa
ar
rt
ts
s
D
De
es
sc
cr
ri
ip
pt
ti
io
on
n
1. LED indicator & Learn/Test Button
Press the button to transmit a learn/test code and enter Test
mode for 3 minutes. The LED will light up whenever the Detector
is activated der Test mode.un
2. Mounting Holes (Covered by White Caps)
3 Wire Input Terminial 1 .
Connect the terminal to any Normal Close (N.C) device
4. Wire Input Terminial 2
Connect the terminal to Roller Shutter
5. Jumper Switches
For Jumper Switch functions, refer to later section Jumper
Switch Setting.
6 Battery Insulator .
7. Tamper Switch
8. Knockout for Extension Terminals
9. Rib-Mark
10. Magnet
P
Pa
ac
ck
ka
ag
ge
e
C
Co
on
nt
te
en
nt
t
1 x Door Contact
2 x wall plugs and screws
1 x adhesive pads
1 x 3V lithium battery (pre-installed)
.
Put the Control Panel into learning mode, then press the learn
button to transmit learn code. Please refer to Control Panel
manual to complete learn in process.
The Detector can be used either as a door/ window sensor or
transmitter for shutter or wired device, or all at the same time.
Choose the mounting location according to the Door Contacts
usage.
As a Door/window sensor: mount the main body on the
door/window frame, and the magnet on the door/window.
Mount as high as possible.
As a transmitter for shutter or wired device: mount close
to the device accordingly.
Do not mount on metallic surface.
1. Remove the white caps covering the 2 mounting holes.
2. Drill holes into the mounting location using the holes as
template.
3. Screw the sensor onto the wall or door/window frame with the
screws and plugs provided.
As a Door/ Window Sensor
4. Align the magnet with the Rib Mark on main body; screw the
magnet onto the door/window or apply with double-side
adhesive tape. The gap between the body and the magnet
should be no more than 15 mm.
As a Transmitter
5. Break through the knockout at top of the cover
6. For general wired device: connect the wire from device to
Wire Input Terminal . Multiple wired devices can be 1
connected to single Door Contact as long as the devices form
a closed loop with the Detector (Figure A)
7. For roller shutter: connect the wire from roller shutter to Wire
Input Terminal 2. (Figure B)
Figure A Figure B
8. Replace the white caps.
L
Le
ea
ar
rn
ni
in
ng
g
IInnssttaallllaattiioonn
Frame
Door/
Window


Produkt Specifikationer

Mærke: Blaupunkt
Kategori: Overvågningskamera
Model: DC-S3
Produktfarve: Hvid
Relativ luftfugtighed ved drift (H-H): 0 - 85 %
Driftstemperatur (T-T): -10 - 40 °C
Dimensioner (BxDxH): 32 x 22 x 107 mm
Forbindelsesteknologi: Trådløs
Sensor afstand: 300 m

Har du brug for hjælp?

Hvis du har brug for hjælp til Blaupunkt DC-S3 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Overvågningskamera Blaupunkt Manualer

Blaupunkt

Blaupunkt VIO-H30 Manual

10 April 2024
Blaupunkt

Blaupunkt RC-S3 Manual

20 Oktober 2023
Blaupunkt

Blaupunkt WS-S1 Manual

25 August 2023
Blaupunkt

Blaupunkt SA 2700 Manual

11 August 2023
Blaupunkt

Blaupunkt CO-S1 Manual

6 August 2023
Blaupunkt

Blaupunkt KP-S1 Manual

27 April 2023
Blaupunkt

Blaupunkt DC-S3 Manual

7 April 2023
Blaupunkt

Blaupunkt IRC-S2 Manual

24 December 2022
Blaupunkt

Blaupunkt VIO-B40 Manual

20 December 2022
Blaupunkt

Blaupunkt IPC-S1 Manual

28 November 2022

Overvågningskamera Manualer

Nyeste Overvågningskamera Manualer