RANGE HOOD CORD KIT Installation Instructions
WARNING CORD KIT INSTALLATION
1. Remove this
electrical knockout
only.
2. Use bushing to
connect plate to
hood.
BUSHING
PLATE
CORD
CONNECTOR
3. Align plate with
knockout and attach
cord connector to
hood.
BLACK
WIRES
WHITE
WIRES
GREEN
GROUND WIRE
GROUND
SCREW*
4. Connect black wires together. Connect togeth-white wires
er. Connect green ground wire ground screw beneath .
* If the range hood has an internal ground connection beneath
a ground screw, A SECOND GROUND SCREW MUST BE
USED for the cord kit ground. 99523894K
CAUTION
TO REDUCE THE RISK OF FIRE AND ELECTRICAL SHOCK,
THIS RANGE HOOD CORD-CONNECTION KIT IS U.L. CLAS-
SIFIED ONLY FOR USE WITH THE RANGE HOOD MODEL
SERIES LISTED BELOW:
BROAN SERIES
40000, 41000, 42000,
43000, 46000,BCDF1,
BCDJ1, BCSD1,
BCSEK1, BKDB1,
BKDEG1, BKSA1,
BKSH1, TEN1, TEN2,
BPDP1, ALT1, ALT2,
ALT3, CLDA1, CLDH1,
CLSC1, CRDE1,
CRSF1, SPE1 and
ALT4
NUTONE SERIES
RL, ACS, AR1,
AHDA1, AHSA1,
AVDF1, AVSF1
and NPDP1
KENMORE SERIES
5094, 5104, 5134, 5164, 5184, 5324, 5334,
5128, 5139, 5141, 5129, 5126, 5135 and 5140
ELECTRICAL RECEPTACLE LOCATION
A grounded, electrical receptacle for this cord kit must be in a
location that will not allow the cord to come in contact with any
heat source. Inside the cabinet above the range is the most com-
mon location.
Do not plug into receptacles that would permit cord to come
into contact with heat sources.
FOR USE WITH RANGE HOODS ONLY.
GROUNDING INSTRUCTIONS
Range Hoods must be grounded. In the event of an electrical short
circuit, grounding reduces the risk of electric shock by providing
an escape wire for the electric current. After attaching this cord
kit to the range hood, it is equipped with a cord having a ground-
ing wire with a grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded.
WARNING - Improper grounding can result in a risk of electric
shock.
Consult a qualified electrician if the grounding instructions are not
completely understood, or if doubt exists as to whether the range
hood is properly grounded.
Do not use an extension cord. If the power supply cord is too short,
have a qualified electrician install an outlet near the appliance.
This kit includes the following:
(1) 36” Cord & Plug with Cord Connector
(1) Anti-Rotation Plate with Lock Bushing
(2) Wire Nuts
WIRING CONNECTIONS
Other cord kits are not U.L. Classified - unless the specific
model numbers are listed.


Produkt Specifikationer

Mærke: Broan
Kategori: Emhætte
Model: 403023

Har du brug for hjælp?

Hvis du har brug for hjælp til Broan 403023 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Emhætte Broan Manualer

Broan

Broan BCSEK136WW Manual

12 Januar 2025
Broan

Broan BKDB136WW Manual

11 Januar 2025
Broan

Broan Elite RMIP45 Manual

1 September 2024
Broan

Broan Elite 619004 Manual

1 September 2024
Broan

Broan BWS1304SS Manual

1 September 2024
Broan

Broan EWS1306BLS Manual

1 September 2024
Broan

Broan BWP1304SS Manual

1 September 2024
Broan

Broan PM250 Manual

1 September 2024

Emhætte Manualer

Nyeste Emhætte Manualer

Røros

Røros Tender Manual

22 Februar 2025
XO

XO VW48KSE Manual

22 Februar 2025
XO

XO VV248SC Manual

22 Februar 2025
XO

XO VW36SC Manual

22 Februar 2025
XO

XO VW42KSE Manual

22 Februar 2025
XO

XO VW36KSE Manual

22 Februar 2025
XO

XO VV242KSE Manual

22 Februar 2025
XO

XO VW30SC Manual

22 Februar 2025
Siemens

Siemens LI48932 Manual

22 Februar 2025
Smeg

Smeg KSED95MBL Manual

21 Februar 2025