WARNING
CAUTION
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended the manufac-by
turer. If questions, contact the manufacturer at the you have
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power at service off
panel and lock the service disconnecting means prevent to
power from being switched on accidentally. When the ser-
vice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a the service tag, to
panel.
3. Installation and electrical wiring must be done a work by
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
4. Sufficient air is needed proper combustion and exhaust-for
ing of gases through the flue (chimney) of fuel burning equip-
ment prevent backdrafting. Follow the heating equipment to
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society of Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. This product may sharp edges. Be careful avoid cuts have to
and abrasions during installation and cleaning.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must be vented the outdoors.always to
8. Use only metal ductwork.
9. Do not use this with solid-state speed control fan any device.
10. As an alternative, this product be installed with the may UL-
approved cord kit designated the product, following in-for
structions packed with the cord kit.
11. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings.
Boilovers cause smoking and spillovers that ig-greasy may
nite. Heat oils slowly on or medium settings.low
2. Always turn hood ON when cooking at high heat or when
cooking flaming foods (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
3. Clean ventilating fans frequently. Grease should not be al-
lowed accumulate on or filter.to fan
4. Use proper pan size. use cookware appropriate Always for
the size of the surface element.
TO TO REDUCE THE RISK OF INJURY PERSONS IN THE
EVENT OF A RANGE GREASE FIRE, OBSERVE THE TOP
FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or metal then turn the burner. BE CAREFUL tray, off TO
PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
EVOLUTIONTM 2
QP2 Series Range Hoods
READ AND SAVE THESE INSTRUCTIONS
FOR DOMESTIC COOKING ONLY
WARNING
2. NEVER PICK UP A FLAMING PAN — You be burned or may
spread the fire.
3. DO USE WATER, including dishcloths or towels - NOT wet
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know a Class ABC extinguisher and you have you
already know operate it.how to
B. The is small fire and contained in the area where it started.
C. The department is being called.fire
D. You can fight the with your back an exit.fire to
* Based on “Kitchen Safety Tips” published NFPA.Fire by
1. For indoor use only.
2. For general ventilating use only. Do not use exhaust haz-to
ardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbal-
anced impeller, keep drywall spray, construction dust, etc.,
off power unit.
4. Do not use cooking equipment greater than 60,000 over
BTU/hr. as the blower motor will shut down intermittantly.
5. Your hood motor has a thermal overload which will automati-
cally shut the motor if it becomes overheated. The motor off
will restart when it cools down. If the motor continues shut to
off and restart, the hood serviced.have
6. The of the hood MUST BE LESS than 24” and at a top NOT
maximum of 30” above cooktop best capture of cooking for
impurities.
7. This hood is not intended be used as a shelf.to
8. Please read specification label on product further infor-for
mation and requirements.
Installer: Leave this manual
with the homeowner.
Homeowner: Cleaning, Maintenance and
Operating instructions on page 2.
NOTE If hood is be installed non-ducted:to
Purchase set a of (2) non-ducted filters 30” for wide
hoods (Model BPPF30) & 36” wide hoods (Model
BPPF36) or a set of (3) non-ducted filters 42” for wide
hoods (Model BPPF42) from your local distributor or
retailer and attach them the aluminum to mesh filters.
Register your product online at: www.broan.com


Produkt Specifikationer

Mærke: Broan
Kategori: Afzuigkap
Model: QP230BL Evolution 2

Har du brug for hjælp?

Hvis du har brug for hjælp til Broan QP230BL Evolution 2 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Afzuigkap Broan Manualer

Broan

Broan Elite RMIP45 Manual

1 September 2024
Broan

Broan Elite 619004 Manual

1 September 2024
Broan

Broan BWS1304SS Manual

1 September 2024
Broan

Broan EWS1306BLS Manual

1 September 2024
Broan

Broan BWP1304SS Manual

1 September 2024
Broan

Broan PM250 Manual

1 September 2024
Broan

Broan Elite 614804EX Manual

1 September 2024
Broan

Broan BWP1364SS Manual

1 September 2024
Broan

Broan BBN3306SSC Manual

1 September 2024
Broan

Broan BWT1304SSB Manual

1 September 2024

Afzuigkap Manualer

Nyeste Afzuigkap Manualer

Novy

Novy Canopy glass 874 Manual

16 September 2024
Scholtès

Scholtès H 5890 Manual

16 September 2024
Balay

Balay 3BT262MX Manual

16 September 2024
Smeg

Smeg KCVR9NE Manual

16 September 2024
Miele

Miele DA 419-4 SS Manual

16 September 2024
Bestron

Bestron TSCH80X Manual

16 September 2024
Westinghouse

Westinghouse WRR614SB Manual

16 September 2024
Zanussi

Zanussi ZH6020W/E Manual

16 September 2024