Crestron ZUMMESH-PART Manual


Læs nedenfor 📖 manual på dansk for Crestron ZUMMESH-PART (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 4 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
ZUMMESH-PART
Zūm™ Wireless Partition Sensor
Installation Guide
Description
The Crestron® Zūm wireless partition sensor (ZUMMESH-PART) is used to facilitate
seamless control between two Zūm spaces.
Powered with 24 VDC, the ZUMMESH-PART conveniently receives power from a
ZUMMESH-SIM or any Crestron 24 VDC power supply (both not supplied).
Zūm Overview
A Zūm space is an area, such as a board room or conference room, that is equipped
with Zūm mesh devices such as dimmers, switches, keypads, and motion sensors.
Zūm mesh devices create a wireless mesh network that facilitates seamless
communication between devices without using an independent wireless gateway.
Centralized control and monitoring is enabled by adding a ZUMMESH-NETBRIDGE
to the space and integrating a ZUMNET-GATEWAY and ZUM-FLOOR-HUB to the
Crestron control system (all not included).
NOTE: The ZUMMESH-NETBRIDGE requires a compatible J-box device (not
included) to provide power.
Install the ZUMMESH-PART
NOTE:
Install and use this product in accordance with appropriate electrical
codes and regulations.
Sensors must be mounted on a vibration-free surface.
Determine the Mounting Location
Position the ZUMMESH-PART about 2 ft (0.6 m) away from the partition. If
necessary, the ZUMMESH-PART can be mounted up to 4 ft (1.2 m) from the
partition. The lens on the ZUMMESH-PART must face the partition so that when
the partition is opened, the sensor sees the unobstructed room.
2 ft (0.6 m)
Partition
Mount the ZUMMESH-PART in a 1-gang electrical box:
1. Turn off the system power.
2. Connect the 2-pin terminal block to the 24 and G port on the ZUMMESH-PART.
When making connections, use 14 to 26 AWG wire, strip the ends of the wires
7/16 in (11 mm) (avoid nicking the conductors), and tighten the connector to
5 in-lb (0.5 to 0.6 Nm).
3. Secure the ZUMMESH-PART to the 1-gang box using the included screws. The
sensors must face towards the partition.
4. Attach a decorator style faceplate (not included).
5. Turn the system power on.
Standard 1-gang
electrical box
Ceiling
Mounting
screws (2)
Faceplate
(Not included)
ZUMMESH-PART
Mount the ZUMMESH-PART on a flat surface:
1. Turn off the system power.
2. Remove the two screws from the back of the ZUMMESH-PART and then
remove the bracket. Retain the screws.
3. Install the flat bracket to the back of the ZUMMESH-PART using the screws
removed in step 2.
4. Connect the 2-pin terminal block to the 24 and G port on the ZUMMESH-PART.
When making connections, use 14 to 26 AWG wire, strip the ends of the wires
7/16 in (11 mm) (avoid nicking the conductors), and tighten the connector to
5 in-lb (0.5 to 0.6 Nm).
5. Secure the ZUMMESH-PART to the ceiling using screws that are appropriate
for the mounting surface. The sensors must face towards the partition.
6. Attach a decorator style faceplate (not supplied).
7. Turn the system power on.
Ceiling
Mounting
screws (2)
Faceplate
(Not included)
ZUMMESH-PAR
Adjust the ZUMMESH-PART Sensitivity
The ZUMMESH-PART operates by emitting an IR pulse and then measuring the
reflected IR signal. The measurement of the reflected IR signal and the sensitivity
level determines if the partition is closed or open.
The ZUMMESH-PART has high, medium (default), and low sensitivity levels.
High: Use when the partition is not being detected due to distance or partition
material.
Medium (default): Sufficient for most installations.
Low: Use when the partition is falsely detected due to reflectance from other
objects such as the ceiling, light fixtures, etc.
View and Adjust the Sensitivity Level:
The + and – buttons are used to view and adjust the sensitivity of the
ZUMMESH-PART. The + button increases the sensitivity and the - button decreases
the sensitivity.
To view and change the sensitivity level:
1. Press and hold the + or - button until the PART LED blinks.
1 blink: Sensitivity is low
2 blinks: Sensitivity is medium
3 blinks: Sensitivity is high
2. Continue holding the + button to increase the sensitivity or the - button to
decrease the sensitivity. Release the button when the desired sensitivity setting
is achieved.
3. Open and close the partition to verify the sensitivity level. The green PART LED
lights when the partition is closed. It takes several seconds for the
ZUMMESH-PART to determine that the partition is closed.
LED Functionality
PART LED:
Lights green when the partition is closed.
Is off when the partition is open.
NOTE: When the partition is opened or closed, there is a small delay for the
PART LED to change.
RM A LED:
Lights solid red to indicate that the ZUMMESH-PART has not joined Room A.
Once joined to Room A, the LED lights momentarily when a message is received
from a device in Room A.
RM B LED:
Lights solid red to indicate that the ZUMMESH-PART has not joined Room B.
Once joined to Room B, the LED lights momentarily when a message is received
from a device in Room B.
Add the ZUMMESH-PART to Existing Zūm Spaces
NOTE:
Scene 1 should be similar for both spaces. Occupancy sensors will recall
scene 1 for both spaces, so you want them both to recall the similar light
values. To set Scene 1, refer to the Zum Light Control System Setup Guide
(Doc. 7957) at www.crestron.com/manuals.
The ZUMMESH-PART occupies one motion sensor slot in each room. Up
to seven additional motion sensors may be added in each room. When
the partition is opened, all motion sensors operate in unison to determine
occupancy and vacancy.
Do not mix occupancy and vacancy sensors within the combined rooms.
Both rooms must use either occupancy or vacancy sensors.
Add the ZUMMESH-PART to Room A and then Room B by placing the Zūm spaces
in Joining mode. The ZUMMESH-PART is added using button press sequences
on the Zūm devices in the space. When performing the button press sequences,
remember the following:
Perform consecutive button presses at a rate of one press per second.
Transition between button press combinations on the same device within
1 second.
When moving between devices, begin the next button press sequence before
the 4 minute timeout period expires.
Add the ZUMMESH-PART Using an AC powered Keypad, Dimmer, or Switch
1. Place Room A into Joining mode. Room A is the space where the
ZUMMESH-PART is mounted.
a. Press and hold both the top and bottom buttons until the LED lights.
b. Press the top button once.
c. Press the bottom button once. The LEDs on all devices in the space (except
battery powered devices) flash slowly to indicate that the devices are part
of the space and that the space is in Joining mode.
Press and hold until LED lights
Press and hold until LED lights
then then
Press 1x
Press 1x
2. Add the ZUMMESH-PART to Room A.
a. Press the + button 3 times. The RM A LED will flash with each button press
and then turn off.
b. Press and hold the + button until the RM A LED on the ZUMMESH-PART
lights. The ZUMMESH-PART is added to Room A.
Press and hold until LED lightsPress 3x then
3. Press any button on an AC-powered device that is part of the Room A Zūm
space to exit Joining mode.
4. Place Room B into Joining mode as described in step 1 above.
5. Add the ZUMMESH-PART to Room B.
a. Press the - button 3 times. The RM B LED will flash with each button press
and then turn off.
b. Press and hold the - button until the RM B LED on the ZUMMESH-PART
lights. The ZUMMESH-PART is added to Room B.
Press and hold until LED lightsPress 3x then
6. Press any button on an AC-powered device that is part of the Room B Zūm
space to exit Joining mode.


Produkt Specifikationer

Mærke: Crestron
Kategori: Ikke kategoriseret
Model: ZUMMESH-PART
Bredde: 106 mm
Højde: 57 mm
Antal pr. pakke: 1 stk
Driftstemperatur (T-T): 0 - 45 °C
Længde: 34 mm

Har du brug for hjælp?

Hvis du har brug for hjælp til Crestron ZUMMESH-PART stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Crestron Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Märklin

Märklin 72886 Manual

24 Januar 2025
Märklin

Märklin 72797 Manual

24 Januar 2025
Märklin

Märklin 7001 Manual

24 Januar 2025
Hilti

Hilti KCC-WF Manual

24 Januar 2025
Märklin

Märklin 7051 Manual

24 Januar 2025
ATen

ATen KH1516Ai Manual

24 Januar 2025
Adonit

Adonit PD-3A2C Manual

24 Januar 2025
Adonit

Adonit Dash 4 Manual

24 Januar 2025