CP900AVR / CP1200AVR / CP1500AVRT
User Manual ’s
K01-0000003-01
Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at www.cyberpower.com/registration.
Registration certifies your product's warranty, confirms your ownership in the event of a product loss or theft and entitles you to free technica
support.
(SAVE THESE INSTRUCTIONS)
This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive
contaminants. (Please see specifications for acceptable temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover There are no user serviceable parts inside. .
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not
grounded. If you need to de-energize this equipment, turn off and unplug the unit.
CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before installing a computer component.
CAUTION! Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment,
ANSI/NFPA 75.
CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in
accordance with the National Electric Code, ANSI/NFPA 70.
CAUTION! To avoid electrical shock, turn off the unit and unplug it form the AC power source before servicing the battery.
CAUTION! Do not dispose of batteries in a fire. The batteries may explode.
CAUTION! Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical
applications. use in any circumstance that would affect operation and safety of life support equipment, any medical applications or DO NOT
patient care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation
from the aquarium can cause the unit to short out.
DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the unit on any transportation
such as airplanes or ships. The effect of shock or vibration caused ing transit and the damp environment can cause the unit to short out. dur
UNPACKING
Inspect the UPS upon receipt. The box should contain the following:
(1) UPS unit; (2 3) USB device cable; (4) Telephone cable; (5) Warranty registration card; (6) Coaxial Cable ) User’s manual; (
*PowerPanel® Personal Edition software is available on our website. Please visit www.cyberpower.com
and go to the Software Section for free download.
OVERVIEW
The CP900AVR / CP1200AVR / CP1500AVRT provides automatic voltage regulation for inconsistent utility
power. The CP900AVR / CP1200AVR / CP1500AVRT features 890/1080/1500 Joules of surge protection, and
provides battery backup during power outages. The CP900AVR / CP1200AVR / CP1500AVRT ensure
consistent power to your computer system and include software that will automatically save your open files and
shutdown your computer system during a utility power loss.
AUTOMATIC VOLTAGE REGULATOR
The CP900AVR / CP1200AVR / CP1500AVRT stabilize inconsistent utility power. The incoming utility power may be damaging to important data
files, but with Automatic Voltage Regulation, the computer will not experience damaging voltage levels. An Automatic Voltage Regulator
automatically increases low or decreases high voltage to a consistent, computer safe 110v/120v. -acid batteries The unit’s powerful sealed lead
will provide power only if the incoming voltage drops below 90v or increases above 140v.
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Ensure that the equipment plugged into t UPS y (900VA/560W for CP900AVR, he does not exceed the UPS unit’s rated capacit
1200VA/720W for CP1200AVR and 1500VA/900W for CP1500AVRT If the rated capacities of the unit are exceeded, an overload condition ).
may occur and cause the UPS unit to shut down or the circuit breaker to trip.
2. There are many factors that can affect the amount of power that your electronic equipment ll require. For optimal system performance wi
keep the load below 80% of the unit’s rated capacity.
HARDWARE INSTALLATION GUIDE
1. Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure the battery s maximum charge capacity, ’
it is recommended that you charge the battery for at least 8 hours. Your UPS is equipped with an auto-charge feature. When the UPS is
plugged into an AC outlet, the battery will automatically charge when it s turned on or turned off. ’
2. With the UPS unit turned off and unplugged, connect your computer, monitor, and any other peripherals requiring battery backup from the
SURGE/BATTERY outlets. Plug the other peripheral equipment (e.g. printer, scanner, speakers, etc.) into the full-time surge protection outlets.
DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum cleaner, sump pump, or other large electrical device into
the Battery and Surge Protected Outlets The power demands of these devices will overload and possi“ ”. bly
damage the unit.
3. To protect a fax, phone, or modem line, connect a telephone cable from the wall jack outlet to the jack of the UPS. IN
Connect a telephone cable from the UPS OUT jack to protect a modem port on the computer, a telephone, or fax machine.
4. ed Plug the UPS into a 2 pole, 3 wire ground receptacle (wall outlet). Make sure the wall branch outlet is
protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air
conditioner, refrigerator, copier, e .). The warranty prohibits the use of extension cords, outlet strips, and surge tc
strips in conjunction with the UPS unit.
5. Press the power switch to turn the unit on. The Power On indicator light will illuminate green once. and the unit will “beep”
6. n overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at If a
least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
7. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
8. To store the UPS for an extended period of time, cover it and store with the battery fully charged. While in storage, recharge the battery every
three months to ensure optimal battery life.
9. Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility.
DESCRIPTION
1. Power Switch
Can be used as a master on/off switch for equipment connected to the battery power supplied outlets.
2. Power On Indicator
This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.
3. Using Battery Indicator
This LED is illuminated when the unit is providing power from the battery.
4. AVR Indicator
This LED is illuminated when the unit is running in the AVR mode.
5. Over Load Indicator
This LED is illuminated when the unit is overload. You will need to reduce the load.
6. Battery and Surge Protected Outlets
The unit has 4 battery powered/surge protected outlets to ensure temporary uninterrupted operation of your equipment during a power
failure. (DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum cleaner ump pump, or other large electrical , s
device into the Battery and Surge Protected Outlets. The power demands of these devices will overload and possibly damage “ ”
the unit.)
7. Full-Time Surge Protection Outlets
The unit has 4 surge suppression outlets to provide surge and line noise protection.
8. Wiring Fault Indicator(Red)
This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring. If
this is illuminated, user is advised to disconnect all electrical equipment from the outlet and have an electrician check to ensure the outlet is
properly wired. The unit will not provide surge protection without being plugged into a grounded and properly wired wall outlet.
9. Communication Protection Ports
Communication protection ports will protect any standard modem, fax , telephone line, broadband network or Ethernet connection.
10. Circuit Breaker
Located on the back of the UPS, the circuit breaker serves to provide overload and fault protection.
11. Serial/USB Ports to PC
The ports allow connection and communication from the USB or DB-9 serial port on the computer to the UPS unit. The USB port will
communicate with Power -9 port is for use with a serial cable and the Microsoft UPS Service. Panel™ Personal Edition and the DB
For information regarding ordering a serial cable for the unit, please contact technical support at CyberPower System.
Note: Only one of these two ports can be used to communicate with your computer at one time.
12. Coax/Cable/DSS Surge Protection
The Coax/Cable/DSS surge protection ports will protect any cable modem, CATV converter, or DSS receiver.
13. Outlets Designed for AC Adapters
The unit has four outlets spaced to allow AC power adapter blocks to be plugged into the UPS without blocking adjacent outlet s.
REPLACING THE BATTERY
Installation or replacement of batteries located in an OPERATOR ACCESS AREA.
1. When replacing batteries, replace with the same number of the following battery: CyberPower / for CP900AVR, RB1270X2 RB1280X2D
for CP1200AVR and RB1280X2A for CP1500AVRT.
2. sk of energy hazard, 12V, maximum 9 Ampere- battery. Before replacing batteries, remove conductive jewelry such as CAUTION! Ri hour
chains, wrist watches, and rings. High energy through conductive materials could cause severe burns.
3. Do not dispose of batteries in a fire. The batteries may explode. CAUTION!
4. Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic. CAUTION!
5. CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES
ACCORDING TO LOCAL REGULATIONS.
TO REPLACE THE BATTERY
1. Turn off and unplug all connected equipment.
2. Turn the UPS off and unplug it from the AC power source.
3. Turn the UPS upside down.
4. Remove the retaining screw.
5. Slide the battery compartment cover (front panel) completely off of the unit.
6. Remove the batteries from the compartment.
7. Disconnect the battery wires from the batteries.
8. Install the replacement batteries by connecting the red wire and black wire to the same color wires from the battery pack .
9. Put the batteries back into the compartment.
10. Slide back the battery compartment cover and tighten the retaining screw.
11. Recharge the UPS for 8-16 hours to fully charge the battery.
REMINDER: HAZARDOUS WASTEBatteries are consider ed must be disposed of properly. Most retailers that sell lead-acid batteries and
collects used batteries for recycling, as required by local regulations.
DEFINITIONS FOR ILLUMINATED LED INDICATORS
Power
On
Using
Battery
AVR
Overload
Wiring Fault
Alarm
CONDITION
On
O ff
Off
Off
Off
Off
Normal
On
On
Off
Off
On/Off
Two
Beeps
Utility Failure- The UPS is providing power to
battery protected outlets from its battery.
On
On
Off
Off
On/Off
Rapid
Beeps
Utility Failure - The UPS is providing battery
power. Rapid beeping indicates the unit will run
out of power shortly.
On
Off
Off
On
On/Off
Long
Beep
System Overload- Occurs when connected
equipment exceeds the rating of unit. Turn the
UPS off, unplug at least one piece of equipment,
wait 10 seconds, reset the circuit breaker and turn
the unit on.
On
Off
Off
On
On/Off
Long
Beep
Battery Overload- Occurs when connected
equipment exceeds the rating of battery outlets of
the unit. Turn the UPS off, unplug at least one
piece of equipment from battery outlets, wait 10
seconds, reset the circuit breaker and turn the unit
on.
On
Off
On
Off
On/Off
Off
AVR Mode-Max. boost 12% of input voltage for
output regulation while input voltage is from 17%
to 26% under nominal.
On/Off
On/Off
On/Off
Off
On
None
Electrical Wiring Fault- This indicates a wiring
problem with the AC outlet such as bad ground,
missing ground, or reversed wiring. User is
advised to disconnect all electrical equipment
from the outlet and have an electrician check the
outlet to insure proper wiring.
BASIC OPERATION
INSTALLING YOUR UPS SYSTEM
IMPORTANT SAFETY INSTRUCTIONS
PRODUCT REGISTRATION
Produkt Specifikationer
Mærke: | CyberPower |
Kategori: | UPS |
Model: | CP1500AVRT |
Har du brug for hjælp?
Hvis du har brug for hjælp til CyberPower CP1500AVRT stil et spørgsmål nedenfor, og andre brugere vil svare dig
UPS CyberPower Manualer
2 Oktober 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
UPS Manualer
- UPS Ikea
- UPS AEG
- UPS HP
- UPS GYS
- UPS Lenovo
- UPS Gembird
- UPS Tripp Lite
- UPS Digitus
- UPS Dell
- UPS EnerGenie
- UPS Voltcraft
- UPS APC
- UPS Eaton
- UPS V7
- UPS Emerson
- UPS LC-Power
- UPS SurgeX
- UPS Equip
- UPS Murr Elektronik
- UPS Furman
- UPS Block
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Middle Atlantic
- UPS Minuteman
- UPS Riello
- UPS Maruson
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nyeste UPS Manualer
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
4 Oktober 2024
4 Oktober 2024