CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK:
Use only in dry locations and only indoors.
DO NOT plug into another relocatable power tap.
DO NOTdaisy chain” surge protectors.
DO NOT use with any aquarium equipment.
DO NOT use if properly grounded outlets are not available.
DO NOT install this device if there is less than 10 meters (30 feet) of wire between
the electrical outlet and electrical service panel.
DO NOT use for medical or life support equipment. This device features an internal
protection that will disconnect the surge protective component at the end of its
useful life, but it will maintain unprotected power to the load.
FOR MORE INFORMATION
Visit CyberPowerSystems.com for more information regarding:
• Product information and certifications
• Product warranty
• Connected equipment guarantee
TECHNICAL SUPPORT
Visit: CyberPowerSystems.com/support
Toll-Free: 1-877-297-6937
© 2022 Cyber Power Systems (USA), Inc. All rights reserved.
All other trademarks are the property of their respective owners.
FEATURES
1. ON/OFF Reset Control Switch and Circuit Breaker
Controls power to all outlets. The switch is also a 15 A
breaker. When an overload occurs, it will automatically
switch o. To resume operation, ensure the overload
condition is removed and reset the surge protector by
switching the unit ON.
2. Six Standard Outlets
SURGE PROTECTOR INSTRUCTIONS
1. Set power switch into the “OFF” position. Plug the surge
protector into a standard grounding wall receptacle
by fully inserting the plug and ensure that there are no
exposed conductors.
2. Make sure electronic equipment is turned o before
plugging into the surge protector outlets. Do not use
extension cords to connect equipment to the surge
protector.
3. Set the power switch into the “RESET” position.
The surge protector will now be providing power
and surge protection.
4. Connected equipment can now be turned on.
TROUBLESHOOTING
If the ON/OFF is switched OFF, the 15 Amp circuit breaker may have tripped.
Examine your connected equipment and remove the device that is overloading
the circuit. Then, turn the ON/OFF switch back to RESET.
6-OUTLET
SURGE PROTECTOR
CSB604/CSB606/CSB606W
USER MANUAL
YOUR ULTIMATE ALLY IN POWER
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379
CyberPowerSystems.com
SPECIFICATIONS
Model Number: CSB604/CSB606/CSB606W
Outlets: 6 Standard Outlets
Surge Protection: 900 Joules
Electrical Rating: 125 V / 15 A / 1875 W
UL Clamping Voltage: UL 1449 3rd / 500 V
(H-N, H-G, N-G)
3 AC Lines Protected: H-N: 15,000 A,
H-G: 15,000 A,
N-G: 15,000 A
Response Time: Less than 1 nanosecond
Attenuation: Up to 32 dB
Circuit Breaker: Resettable 15 Amp
EMI/RFI Filtration: 150 kHz to 100 MHz
i WARNING: This product can expose you to chemicals including bisphenol A (BPA)
and styrene (ABS), which is known to the State of California to cause reproductive
harm and cancer. For more information, go to www.P65Warnings.ca.gov.
CONFORMANCE APPROVALS
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interfer-
ence to radio or television reception, which can be determined by
turning the equipment o and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to
operate the equipment.
1
2


Produkt Specifikationer

Mærke: CyberPower
Kategori: Ikke kategoriseret
Model: CSB604
Tænd-/slukkontakt: Ja
Produktfarve: Sort
Fjernbetjening inkluderet: Ingen
LED-indikatorer: Strøm
Kabellængde: 1.219 m
Bæredygtighedscertifikater: RoHS
Strømstik: NEMA 5–15P
Nominel indgangsspænding: 125 V
AC udgange, antal: 6 AC stikkontakt(er)
AC stikkontakt typer: NEMA 5–15R
Overspænding energivurdering: 900 J
Nominel udgangsstrøm: 15 A
Spændingsblokering: 400 V

Har du brug for hjælp?

Hvis du har brug for hjælp til CyberPower CSB604 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret CyberPower Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

MSW

MSW -RF15S Manual

25 December 2024
MSW

MSW -HFCV-A7 Manual

25 December 2024
MSW

MSW -HFCV-A5 Manual

25 December 2024
MSW

MSW -LRL2T-1 Manual

25 December 2024
MSW

MSW -HFCV-A6 Manual

25 December 2024
Philips

Philips SWF2620 Manual

25 December 2024
Philips

Philips 13BDL4150IW Manual

25 December 2024
Vivax

Vivax TS-950B Vintage Manual

24 December 2024