CyberPower CyberShield CS24C12V2-E Manual
CyberPower
UPS
CyberShield CS24C12V2-E
Læs nedenfor 📖 manual på dansk for CyberPower CyberShield CS24C12V2-E (2 sider) i kategorien UPS. Denne guide var nyttig for 3 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
User’s Manual for
CyberShield
CS24C12V2-E
CyberShield Battery Backup Power Supplies are designed to provide a
local power solution for cable telephony, wireless local loop (WLL), and
fiber to the home (FTTH) broadband equipment.
IMPORTANT SAFETY WARNINGS
(SAVE THESE INSTRUCTIONS)
This manual contains important instructions regarding the installation and operation of this device.
Read this manual thoroughly before attempting to unpack , install or operate this device
CAUTION! The battery can energize hazardous live parts inside even when the AC input power is
disconnected.
CAUTION! To reduce the risk of electric shock, do not remove the cover, except to service the
battery. No user serviceable parts inside, except for the battery.
CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before
servicing the battery or installing a computer component.
ENCLOSURE INSTALLATION
Carefully follow these instructions during installation of this device:
1.) Carry out the installation in a safe area that is free of excessive dust and has adequate airflow.
2.) Screws must be appropriate for total weight of the Battery Backup Power Supply and the
mounting surface material .
3.) Do not operate the Battery Backup Power Supply where the temperature and humidity are
outside the specified limits. (Refer to specifications in this manual.)
BATTERY REPLACEMENT
This battery is hot-swappable. As long as utility power is on , you may leave the Battery Backup
Power Supply and connected equipment on while replacing a new battery.
Once the battery is disconnected, the connected equipment is not protected from power
outages.
Deliver spent batteries to a recycling facility or ship to the manufacturer in the
replacement battery packing material.
WARNING INDICATOR
OPERATION
Connect: Equipment and Power
Step1. Plug the Battery Backup Power Supply power cord into the utility power cord inlet
Step2. Plug the Battery Backup Power Supply power cord into the wall outlet.
The Battery Backup Power Supply battery charges when it is connected to utility power.
The battery charges fully during the first of normal operation. Do not expect 24 hours
full battery run capability during this initial charge period.
COLD START
The cold start feature is for applying power to the Battery Backup Power Supply and connected
equipment when the Battery Backup Power Supply is off and there is no utility power. Before using
the cold start feature, please make sure the battery is charged. To enable the cold start feature,
press the recessed cold start button with a small pointed object.
Battery Backup Power Supply is on utility power.
Battery Backup Power Supply is on battery power.
DC output power is provided by the battery or
utility power.
The battery is not connected or the battery needs to be
replaced.
Green
Yellow
Green
Red
Indicator Color Condition
Step 1:
a. Remove the case screw.
b. Open the battery cover.
Step 2:
a. Unstrap strap from battery.
b. Slide battery off of the
shelf.
c. Disconnect battery cable
connector at the chassis end.
Step 3:
a. Use the enclosed installation template to
mark an installation location for the unit.
b. Mount the unit on the wall with 3 mounting
screws into the keyhole slots.
c. Tighten the screws to secure the units.
d. Connect the battery connector and replace
the battery back.
Step 1:
a. Remove the case screw.
b. Open the battery cover.
Step 2:
a. Loosen the battery strap.
b. Disconnect battery cable connector
to remove battery.
c. Replace with new battery and
re-connect the battery connector.
Step 3:
a. Tighten the battery strip
b. Close the battery cover and
lock the case screw.
Front Panel
CS24C12V2-E
INTELLIGENT BACK-UP PO WER
INTELLIGENT BACK-UP PO WER
INTELLIGENT BACK-UP PO WER
INTELLIGENT BACK-UP PO WER
INTELLIGENT BACK-UP PO WER
TM
TM
TM
TM
TM
AC
OUTPUT
BATTERY
Installation Suggestion:
To prevent the unit from intrusion of foreign matter, we suggest that the unit should be mounted on
a piece of wood which should then be attached to a wall underneath eaves.
Power Cable Selection:
A power cable (4.5m max.) being identified as 18AWG, "OUTDOOR" or "WATERPROOF"
should be selected while necessary.
Produkt Specifikationer
Mærke: | CyberPower |
Kategori: | UPS |
Model: | CyberShield CS24C12V2-E |
Har du brug for hjælp?
Hvis du har brug for hjælp til CyberPower CyberShield CS24C12V2-E stil et spørgsmål nedenfor, og andre brugere vil svare dig
UPS CyberPower Manualer
2 Oktober 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
UPS Manualer
- UPS Ikea
- UPS AEG
- UPS HP
- UPS GYS
- UPS Lenovo
- UPS Gembird
- UPS Tripp Lite
- UPS Digitus
- UPS Dell
- UPS EnerGenie
- UPS Voltcraft
- UPS APC
- UPS Eaton
- UPS V7
- UPS Emerson
- UPS LC-Power
- UPS SurgeX
- UPS Equip
- UPS Murr Elektronik
- UPS Furman
- UPS Block
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Middle Atlantic
- UPS Minuteman
- UPS Riello
- UPS Maruson
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nyeste UPS Manualer
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
4 Oktober 2024
4 Oktober 2024