CyberPower ENVIROSENSOR Manual


Læs nedenfor 📖 manual på dansk for CyberPower ENVIROSENSOR (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 9 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Environment Sensor
ENVIROSENSOR
User’s Manual
Package Contents
Flat Head Screw (M3x20)
with Plastic Nylon Anchor
CAT5 RJ45 Ethernet Cable
(10 feet/3.05 m)
ENVIROSENSOR Hook and Loop Tape User’s Manual
Product Features
K01-0000207-00
Overview
The CyberPower environmental sensor (ENVIROSENSOR)
along with select SNMP/HTTP cards (RMCARDXXX) or most
Switched and Monitored PDUs enables users to monitor the
temperature and humidity of a server closet and/or datacenter
remotely. With CyberPower's PowerPanel Business Edition
software, users can establish thresholds that will automatically
notify users when an event has occurred via email, SMS and
SNMP traps. Additionally, the ENVIROSENSOR provides 4 input
dry contacts that enable users to monitor the status of connected
devices, such as door switch sensors.
Features include:
• Real time environment monitoring
• Remote management and configuration of the sensor via Web
Browsers or NMS
• Automatic events notification via email, SMS and SNMP traps
• 4 input dry contacts application interface provided
• Displays the name and location of the sensor and
connected devices
A. LED
B. Input Dry Contact 1-4
C. Common Connection
D. RJ45 Port
(connect to RMCARD/PDU)
NOTE: Please refer to Appendix
for Input Dry Contact Application.
A
DATA
STATUS
COM
41 2 3
CBD
Technical Specification
Installation Guide
Method 1- Hook and Loop Tape
Mounting
Step 1. Clean the surface of the
area where the sensor will
be installed. Apply one side
of the hook and loop tape
to the bottom of the sensor
and the other side to the
sensor location.
Step 2. Attach the sensor on the
surface and hold for about 5
seconds to ensure cohesion.
NOTE: Once the sensor is installed,
you will want to leave it in place to
ensure the the hook and loop tape
maintains its adhesiveness.
Step 3. To connect the sensor with
RMCARD/PDU, use the
attached RJ45 Ethernet
Cable. Plug one end into the
RJ45 Port and the other end
into the RMCARD/PDU.
NOTE: If the distance of
RMCARD/PDU and the sensor is
longer than 10 feet/3.05 m, use a
standard RJ45 Ethernet Cable as
needed (max 50 feet/15 m).
Universal RX/TXLink
RMCARD2 03
Copyright © 2011 CyberPower Systems, Inc.
ENVIROSENSOR
Input Voltage 7V - 28V
Halt mode 72 mW/
Power Dissipation Normal mode 110 mW
(Default 12V input)
Measurement Range and Accuracy
Temperature 32-158 with accuracy ± 1.8 /℉ ℉
0-70 with accuracy ± 1℃ ℃
Humidity 10-90 RH with accuracy ± 2%
Communication
Connection Port RJ45 Port
Input Dry Contact 4
Physical
Dimensions (L x W x H) 2.32 x 1.77 x 1.14 inches/
59 x 45 x 29 mm
Weight 1.46 oz /41.5 g
Safety Approvals FCC Class B, CE, C-Tick
Warranty 3 Year Limited


Produkt Specifikationer

Mærke: CyberPower
Kategori: Ikke kategoriseret
Model: ENVIROSENSOR

Har du brug for hjælp?

Hvis du har brug for hjælp til CyberPower ENVIROSENSOR stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret CyberPower Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

MSW

MSW -RF15S Manual

25 December 2024
MSW

MSW -HFCV-A7 Manual

25 December 2024
MSW

MSW -HFCV-A5 Manual

25 December 2024
MSW

MSW -LRL2T-1 Manual

25 December 2024
MSW

MSW -HFCV-A6 Manual

25 December 2024
Philips

Philips SWF2620 Manual

25 December 2024
Philips

Philips 13BDL4150IW Manual

25 December 2024
Vivax

Vivax TS-950B Vintage Manual

24 December 2024