CyberPower RB1290X6D Manual

CyberPower Batteri RB1290X6D

Læs nedenfor 📖 manual på dansk for CyberPower RB1290X6D (3 sider) i kategorien Batteri. Denne guide var nyttig for 29 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/3
1
4 5
2 3
1
3 4
5
2
21
43
5
21
3
5
4
21
43
5
21 3
54 6
Replacement Battery Pack Table
Model Name Battery QTY UPS or EBM Model
For USA and Canada:
4241 12th Ave East, Suite 400
Shakopee, MN 55379
Toll-free: (877) 297-6937
For all other regions:
Please visit our website for
local contact information.
CyberPower Systems, Inc.
www.cyberpower.com
OL1000RTXL2U, OL1500RTXL2U, BP36V60ART2U (LEFT),
OL1000ERTXL2U, OL1500ERTXL2U, BPE36V60ART2US (LEFT)
BP36V60ART2U (RIGHT), BPE36V60ART2US (RIGHT)
OL1000XL, OL1000EXL, OL1500XL, OL1500EXL
OL2200RTXL2U, OL3000RTXL2U, OL3000RTXL2UHV,
OL2200ERTXL2U, OL3000ERTXL2U
BP72V60ART2U, BPE72V60ART2US
OL2200XL, OL3000XL, OL2200EXL, OL3000EXL
BP240VL3U02, BP240V50A, BP240V50ART3U, OL8000, OL10000,
BPE240V50A, BPE240V50ART3U, OL8000E, OL10000E,
BPE240V50AS, BPE240V50ART3US
BP240VL3U01, BP240V30A, BP240V30ART3U, OL6000,
BPE240V30A, BPE240V30ART3U, OL6000E, BPE240V30AS,
BPE240V30ART3US
BP72V60ART2U, BPE72V60ART2US
BP36V60ART2U, BPE36V60ART2US
BP240V50A, BP240V50ART3U, OL8000, OL10000, BPE240V50A,
BPE240V50ART3U, OL8000E, OL10000E, BPE240V50AS,
BPE240V50ART3US
BP240V30A, BP240V30ART3U, OL6000, BPE240V30A,
BPE240V30ART3U, OL6000E, BPE240V30AS, BPE240V30ART3US
OL5KRTHD, OL6KRTHD, OL5KERTHD, OL6KERTHD
BP144VL2U01, BPE144VL2U01
RB1290X3L,
RBP0074
RB1290X3R,
RBP0079
RB1290X3A,
RBP0075
RB1290X6A,
RBP0076
RB1290X6B,
RBP0077
RB1290X6C,
RBP0078
RB1290X10,
RBP0072
RB1270X10,
RBP0073
RBP0131
RBP0132
RBP0133
RBP0134
RBP0144,
RB1260X12
RBP0145,
RB1290X6D
3
3
3
6
6
6
10
10
12
6
20
20
12
6
Battery Replacement
Instructions
K01-0000459-03
All CyberPower Systems replacement battery cartridges listed
in this manual use Non-Spillable Sealed Lead Acid Batteries.
CyberPower Systems encourages environmentally sound
methods for disposal and recycling of its battery cartridges.
Please dispose of and/or recycle your batteries in accordance
to the local regulations of your state.
Smart App Online Tower 6-10KVA SeriesSmart App Online Tower 1-3KVA Series
Smart App Online EBM for RT 1-1.5KVA SeriesSmart App Online RT 1-3KVA Series
Smart App Online RT 6-10KVA SeriesSmart App Online EBM for RT 2-3KVA Series
MODEL: OL1000RTXL2U, OL1500RTXL2U, OL2200RTXL2U,
OL3000RTXL2U, OL3000RTXL2UHV, OL1000ERTXL2U,
OL1500ERTXL2U, OL2000ERTXL2U, OL3000ERTXL2U,
OL1000RT JP, OL1500RT JP, OL2200RT JP,
OL3000RT JP
MODEL: OL1000XL, OL1500XL, OL2200XL, OL3000XL,
OL1000EXL, OL1500EXL, OL2000EXL, OL3000EXL,
OL1000XL JP, OL1500XL JP, OL2200XL JP, OL3000XL JP
MODEL: BP36V60ART2U, BPE36V60ART2U, BPE36V60ART2US
MODEL: BP240VL3U01, BP240VL3U02, BP240V30ART3U,
BP240V50ART3U, BPE240V30ART3U,
BPE240V50ART3U,BPE240V30ART3US,
BPE240V50ART3US
MODEL: OL6000, OL8000, OL10000, OL6000E, OL8000E,
OL10000E
MODEL: BP72V60ART2U, BPE72V60ART2U, BPE72V60ART2US
1 . Remove the front panel.
2 . Remove the screws securing the battery retention panel.
3 . Pull the battery pack out together with the retention panel slowly
and then put the new battery pack back into the UPS.
4 . Reconnect the battery pack connectors to the UPS. Then tighten
the screws of the battery retention panel.
5 . Reinstall the front panel.
1 . Remove the front panel.
2 . Remove the screws securing the battery retention panel.
3 . Pull the battery pack out together with the retention panel slowly
and then put the new battery pack back into the UPS.
4 . Reconnect the battery pack connectors to the UPS. Then tighten
the screws of the battery retention panel.
5 . Reinstall the front panel.
1 . Remove the front panel.
2 . Remove the screws securing the battery retention panels.
3 . Pull the battery packs out together with the retention panels
slowly and then put the new battery packs back into the EBM.
4 . Reconnect the battery pack connectors to the EBM enclosure.
Then tighten the screws of the battery retention panel.
5 . Reinstall the front panel.
1 . Remove the front panel.
2 . Remove the screws securing the battery retention panels.
Unscrew the battery connector retention hardware. Disconnect
the battery power cables and then remove the panel itself.
3 . Pull the battery packs out slowly and then put the new battery
packs back into the compartment.
4 . Reconnect the battery pack to the EBM enclosure and screw on
the battery connector retention hardware. Tighten the screws of
the battery retaining cover.
- It is very important to reconnect battery connections WARNING
with the correct polarity. Connectors are color coded red and
black for positive and negative polarity respectively. Permanent
damage may be caused to the equipment if polarity is reversed.
5 . Reinstall the front panel.
1 . Remove the front panel.
2 . Remove the screws securing the battery retention panel.
3 . Raise the battery retention panel above the battery compartment
opening to allow the battery trays to be pulled out. Then put the
new battery trays into the compartment.
4 . Align and reconnect the battery connectors and tighten the
screws of the battery retention panel.
5 . Reinstall the front panel.
1 . Remove the front panel.
2 . Remove the screws securing the battery retention panel.
3 . Raise the battery retention panel above the battery compartment
opening to allow the battery trays to be pulled out.
4 . Pull the battery trays out slowly and then put the new battery
trays back into the compartment.
5 . Reconnect the battery connectors and tighten the screws of
battery retention panel.
6 . Reinstall the front panel.


Produkt Specifikationer

Mærke: CyberPower
Kategori: Batteri
Model: RB1290X6D

Har du brug for hjælp?

Hvis du har brug for hjælp til CyberPower RB1290X6D stil et spørgsmål nedenfor, og andre brugere vil svare dig




Batteri CyberPower Manualer

Batteri Manualer

Nyeste Batteri Manualer