Dahua Technology DH-PFM904 Manual


Læs nedenfor 📖 manual på dansk for Dahua Technology DH-PFM904 (4 sider) i kategorien overvåge. Denne guide var nyttig for 8 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/4
Attention Device Diagram and Function
Operation Instructions
Safety Information
Thank you for purchasing the Tester. Please read this manual before using the tester.
Please rst read the “safety information” carefully.
The manual should be kept in a safe place for future reference.
Keep the S/N label for a After-sale service within warranty period. Product without the S/N label will
be charged for repair service.
Contact technical support if there is any question or problem with tester or if the tester is damaged.
The images contained within are for illustrative purposes and may not re ect your model.
Passages marked with "*" indicate that only some models have this function.
The working hours of the built-in battery will be reduced when using the V output due to the high 12
power consumption of external devices.
1. Install the wristband
Align the arrows on the wrist band and the arrows on the tester (as shown below), connect the upper part
of the band rst, and then connect the lower part of the band unitl you hear an audible click.
Installing Battery and Recharging
The tester uses a rechargeable lithium-ion polymer battery. To ensure safety when transporting, ensure
the battery is disconnected from the tester.
The device may leave the factory with one of the following two battery placements:
Take o the yellow rubber cover, remove the battery cover of tester, install the battery.
Attention:
Please distinguish positive and negative electrodes when installing batteries.
When the battery level is too low, the charging indicato blinks 3 times and then stops. If the tester cannot
start, please charge.
The wristband quick disassembles from the tester. Press and hold the disassembly button at the bottom
of the tester, and lift it up to separate the wristband from the tester.
Attention: When working at height, please conrm that the wristband is installed successfully to
prevent falling accidents.
Comply with all local electrical codes.
Use the original accessories to avoid damage that may be caused by unauthorized accessories.
Do not expose the product to rain or moisture, which may cause performance degradation or damage.
Do not leave the tester unattended while charging. If the battery becomes too hot, users should cut
o power immediately. Charging time should be no more than 8 hours.
Do not use in high humidity areas. If the equipment gets wet, disconnect immediately the battery,
power cable, and other cables.
Do not use in environments with ammable gases.
Do not attempt to disassemble the instrument. There are no user-serviceable parts inside. Contact
technical support before attemtping any service.
Do not use in environments with strong electromagnetic interference.
Do not use detergent for cleaning. Use a dry cloth to wipe o dirt. If the dirt is di cult to remove, then ff ffi
use a soft cloth moistened with water or a neutral detergent and fully wring it out before use.
The top LED is high brightness LED. Do not look directly at the LED light when it is turned on, so as to
avoid visual injury or other accidents.
1 2 3 4
2. Appearance Introduction
Integrated Mount Tester
User Manual
Arrowhead direction
Force down
5
2
1
1
4
3
6
23456
Function key
Con rmation key
Control camera zoom
Control the direction of the operation button
Data light: Flickers when sending data
Red: Power o and charge
Yellow: Power on and charge
Green: Power on, no charge
Light o : power o , complete charging/no external power supplyff ff
1
2
3
4
5
6
Audio Input: mm audio connector.3.5
Use to connect the device to a computer or to charge the tester.
LED light.
RS Output. Use to control PTZ cameras.485
Analog Video Input BNC Connector.
LED light.
LED light.
Power button to turn the tester on/o . Press and hold for seconds to force shutdown.18
Power Output: DC V/ A , automatically stops when it exceeds this output power.12 1
Attention: Do not connect the external power supply (such as charger, etc.) to the port,
otherwise the tester will be damaged.
1
2
3
4
5
6
7
8
9
-RS485+ AUDIO IN
USB/CHARGE
12V/1A
OUTPUT
PUSH
ON/OFF
Top Side
7
8
9
Left Sife Right Side
Do not use non-standard power charger to charge the tester, which may may damage the tester.
Turning the Device On and O
To turn on the device, press and hold for seconds. The PER/CHG icon illuminates green when 5
the device is turned on.
To turn o the device, press and hold more than seconds.5
When the device is on, press the key to switch to the function select menu. Press multiple times
or use the arrow keys to select a function.
Press the key to enter the selected function.
Analog Video Test
Uused to test Analog SD and Analog HD camera signals. The screen displays the video image, video
format, and signal level. It is also used to send coaxial HD commands though the RS cable to 485
control PTZ cameras.
1. Connecting to an Analog Camera
Use the coax cable with BNC connector to connect to an analog cameras to the tester via the video
input connector on the top side of the tester.
The camera can be self-powered using its own power adapter or use the tester’s V A power output.12 1
5
SCR SCR
Do not exceed the maximum output power of the tester.
12V Power