Daikin Alira X FTKM35WVMA Manual
Daikin
Klimaanlæg
Alira X FTKM35WVMA
Læs nedenfor 📖 manual på dansk for Daikin Alira X FTKM35WVMA (192 sider) i kategorien Klimaanlæg. Denne guide var nyttig for 13 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/192

[Sticker attachment area]
Attach the SSID&KEY sticker of wireless LAN connecting
adapter to the sticker attachment area and keep safe.
D A I K I N R O O M A I R C O N D I T I O N E R
OPERATION MANUAL
M O D E L S
FTXM20W1VMA
FTXM25W1VMA
FTXM35W1VMA
FTXM46W1VMA

1
Features
Enhanced comfort, energy
savings and air cleaning
Other functions
COMFORT AIRFLOW OUTDOOR UNIT QUIET
The airow direction is upward while in
COOL operation, and downward while
in HEAT operation. This function
prevents cold or warm air from blowing
directly on your body. Page 20
OUTDOOR UNIT QUIET operation
assures a low noise level of the
outdoor unit. This function is useful
to maintain a quiet neighbourhood.
Page 24
WEEKLY TIMER
Up to 4timer settings can be saved for each day of the week
according to your family’s life style. The WEEKLY TIMER allows
you to set on/off times and the desired temperature. Page 28
INTELLIGENT EYE
The INTELLIGENT EYE sensor detects human movement and
adjusts the right and left airow direction. If no one is in the room
for more than 20 minutes, the operation automatically changes to
energy saving operation. The INTELLIGENT EYE sensor works
differently depending on the situation. Page 21
MOLD PROOF
The MOLD PROOF function dries the interior of the indoor unit
and provides an ideal environment to suppress the generation of
mold for the indoor unit. Page 17
FLASH STREAMER AIR CLEANING
Flash streamer decomposes mold and allergic substances.
It keeps air in the room and the inside of the air conditioner
clean to make a comfortable space. Page 19

2
ECONO
This function enables efcient operation by
limiting the maximum power consumption.
It is useful when using the air conditioner
and other electrical devices simultaneously
on a shared electrical circuit.
Page 24
Contents
Read Before Operation
Safety Precautions .......................................... 3
Names of Parts ............................................... 5
Preparation Before Operation ...................... 10
Basic Operation
AUTO · DRY · COOL · HEAT ·
FAN Operation ...................................13
Adjusting the Airflow Rate ..................15
Adjusting the Airflow Direction ...........16
Useful Functions
MOLD PROOF Operation ..................17
FLASH STREAMER
AIR CLEANING Operation .................19
COMFORT AIRFLOW Operation .......20
INTELLIGENT EYE Operation ...........21
POWERFUL Operation ......................23
ECONO / OUTDOOR UNIT QUIET
Operation ...........................................24
TIMER Operation
ON/OFF TIMER Operation ................25
WEEKLY TIMER Operation ................28
System control via Smart Control
Wireless LAN connection ...................34
Care
Care and Cleaning ....................................... 38
When the Need Arises
FAQ .............................................................. 42
Troubleshooting ........................................... 43

3
Read Before Operation
Safety Precautions
Read the precautions in this manual carefully
before operating the unit. This appliance is lled with R32.
• Keep this manual where the user can easily nd it.
• The precautions described herein are classied as WARNING and CAUTION. They both contain important information regarding
safety. Be sure to observe all precautions without fail.
WARNING Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION Failure to observe these instructions properly may result in property damage or personal injury,
which may be serious depending on the circumstances.
Never attempt. Be sure to follow the
instructions.
Be sure to establish an earth
connection.
• After reading, keep this manual in a convenient place so that you can refer to it whenever necessary. If the equipment is
transferred to a new user, be sure also to hand over the manual.
WARNING
• Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
• The appliance must be stored in a room without continuously operating ignition sources (for example: open ames, an
operating gas appliance or an operating electric heater).
• Do not pierce or burn.
• Be aware that refrigerants may not contain an odour.
• The appliance must be installed, operated and stored in a room with oor area larger than –*m
2 for 20/25/35/46 class.
*
Since the maximum refrigerant charge of the models is below 1.84kg, it does not have any limitation for the minimum oor area.
Maintain an installation height of 1.8m or more from the oor surface to the bottom of the appliance.
• To avoid re, explosion or injury, do not operate the unit when harmful gases (e.g. ammable or corrosive) are detected near
the unit.
• Be aware that prolonged, direct exposure to cool or warm air from the air conditioner, or to air that is too cool or too warm,
can be harmful to your physical condition and health.
• Do not place objects, including rods, your ngers, etc., in the air inlet or outlet. Product damage or personal injury may
result due to contact with the air conditioner’s high-speed fan blades.
• Do not attempt to repair, dismantle, reinstall or modify the air conditioner yourself as this may result in water leakage,
electric shock or re hazards.
• Do not use ammable spray near the air conditioner, or otherwise re may result.
• Do not use a refrigerant other than the one indicated on the outdoor unit (R32) when installing, moving or repairing. Using
other refrigerants may cause trouble or damage to the unit, and personal injury.
• To avoid electric shock, do not operate with wet hands.
• Beware of re in case of refrigerant leakage. If the air conditioner is not operating correctly, i.e. not generating cool or warm
air, refrigerant leakage could be the cause. Consult your dealer for assistance. The refrigerant within the air conditioner is
safe and normally does not leak.
However, in the event of a leakage, contact with a naked burner, heater or cooker may result in generation of noxious gas.
Do not use the air conditioner until a qualied service person conrms that the leakage has been repaired.
• Do not attempt to install or repair the air conditioner yourself. Improper workmanship may result in water leakage, electric
shock or re hazards. Please contact your local dealer or qualied personnel for installation and maintenance work.
• If the air conditioner is malfunctioning (giving off a burning odour, etc.), turn off power to the unit and contact your local
dealer. Continued operation under such circumstances may result in a failure, electric shock or re hazards.
• Be sure to install an earth leakage circuit breaker. Failure to install an earth leakage circuit breaker may result in electric shock
or re.
• Be sure to earth the unit. Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead.
Imperfect earthing may result in electric shock.
CAUTION
• Do not use the air conditioner for purposes other than those for which it is intended. Do not use the air conditioner for
cooling precision instruments, food, plants, animals or works of art as this may adversely affect the performance, quality
and/or longevity of the object concerned.
• Do not expose plants or animals directly to the airow from the unit as this may cause adverse effects.
• Do not place appliances that produce naked ames in places exposed to the airow from the unit as this may impair
combustion of the burner.
• Do not block the air inlets nor outlets. Impaired airow may result in insufcient performance or trouble.

9
Read Before Operation
Open the front cover
MODE selector button
• Selects the operation mode.
(AUTO/DRY/COOL/HEAT/FAN)
Page 13
Names of Parts
SENSOR button
• INTELLIGENT EYE operation.
Page 21
COMFORT button
•
COMFORT AIRFLOW operation.
Page 20
OFF TIMER button
(NIGHT SET mode)
Page 26
TIMER CANCEL
button
• Cancels the timer setting.
Page 25,26
• Cannot be used for the
WEEKLY TIMER operation.
SELECT button
• Changes the clock, ON/OFF
TIMER and WEEKLY TIMER
settings.
ECONO/QUIET button
• ECONO/OUTDOOR UNIT
QUIET operation. Page 24
SWING button and
MENU button
SWING button
• Adjusts the airow direction.
Page 16
MENU button (push 2 seconds)
• Adjusts the display brightness.
Page 12
• MOLD PROOF operation.
Page 17,18
• Flash streamer air cleaning
operation. Page 19
: WEEKLY button
:
PROGRAMME button
: COPY button
: BACK button
: NEXT button
• WEEKLY TIMER operation.
Page 28
ON TIMER button
Page 25
CLOCK button Page 11

10
Read Before Operation
Preparation Before Operation
CAUTION
Incorrect handling of batteries can result in injury from battery leakage, rupturing or heating, or lead to equipment
failure.
Please observe the following precautions and use safely.
• If the alkaline solution from the batteries should get in the eyes, do not rub the eyes. Instead, immediately ush the eyes with tap water and
seek the attention of a medical professional.
• Keep batteries out of reach of children. In the event that batteries are swallowed, seek the immediate attention of a medical professional.
• Do not expose batteries to heat or re. Do not disassemble or modify batteries. The insulation or gas release vent inside the battery may be
damaged, resulting in battery leakage, rupturing, or heating.
• Do not damage or peel off labels on the batteries.
Remote
controller holder
Remote controller
Screws
Position and
correctly!
+
–
2
3
1
NOTE
Notes on batteries
•
To avoid possible injury or damage from battery leakage or rupturing, remove the batteries when not using the product for long periods of time.
• The standard replacement time is 1 year. Both batteries should be replaced at the same time. Be sure to replace them with new size AAA.
LR03 (alkaline) batteries.
• When battery power has run out, the LCD will begin blinking as an alert that the batteries need replacing. In some cases, when battery
consumption is accelerated owing usage conditions, signal reception may decline before the LCD begins blinking.
• The batteries supplied with the remote controller are for initial operation. The batteries may run out in less than 1 year.
• The usable period of the batteries may be short depending on the manufactured date of the air conditioner.
Notes on remote controller
• Do not drop the remote controller. Do not get it wet.
• Dust on the signal transmitter or receiver will reduce the sensitivity. Wipe off dust with soft cloth.
• Signal communication may be disabled if an electronic-starter-type uorescent lamp (such as inverter-type lamps) is in the room.
Consult the shop if that is the case.
• If the remote controller signals happen to operate another appliance, move that appliance to somewhere else, or consult the service shop.
To insert the batteries
1. Slide the front cover to take it off.
2. Insert 2 dry batteries AAA.LR03 (alkaline).
3. Replace the front cover.
To x the remote controller holder to a wall
1. Choose a place from where the signals reach the unit.
2. Fix the holder to a wall, a pillar, or similar location with the screws supplied with
the holder.
3. Place the remote controller in the remote controller holder.
To attach the deodorizing lter
(enzyme blue)
• If attaching the separately sold lters, attach them before turning the
power on. Page 40
Turn on the circuit breaker
• After the power is turned on, the aps of the indoor unit open and close once to
set the reference position.

11
Read Before Operation
To set the clock
1. Press .
“ ” appears on the LCD.
“ ” and “ ” blink.
2. Press to set the current day of the week.
Display Day of the week
MON Monday
TUE Tuesday
WED Wednesday
THU Thursday
FRI Friday
SAT Saturday
SUN Sunday
3. Press .
“ ” blinks.
4. Press to set the clock to the present time.
• Holding down or rapidly increases or decreases the displayed time.
5. Press .
• Point the remote controller at the indoor unit when pressing the button.
“ ” blinks.
NOTE
Note on setting the clock
• If the indoor unit’s internal clock is not set to the correct time, the ON/OFF TIMER and WEEKLY TIMER will not operate punctually.
Preparation Before Operation

12
Read Before Operation
To set the brightness of the indoor unit lamps
Adjust the brightness of the indoor unit display as desired, or turn OFF the display.
To set
1. Press and hold the button for 2 seconds.
• ‘‘ ” appears on the LCD.
• ‘‘ ” (menu number) blinks.
2. Press or and select menu number .
3. Press to conrm the selected setting.
4. Press or and select the desired
brightness.
BRIGHTNESS Off
BRIGHTNESS High
(default)
BRIGHTNESS Low
5. Press again.
• Brightness will be set to the chosen value.
6. Press to return to the default screen.
NOTE
Note on setting brightness of the indoor unit lamps
• The display automatically returns to the default screen after 60 seconds. To return to the default screen sooner,
press twice.

13
Basic Operation
The air conditioner operates with the operation mode of your choice.
From the next time on, the air conditioner will operate with the same operation mode.
To start
1. Press and select an operation mode.
• Each pressing of the button changes the mode setting in sequence.
AUTO DRY COOL HEAT FAN
2. Press .
• “ ” appears on the LCD.
• The OPERATION lamp lights green.
Display
To stop
Press again.
• “ ” disappears from the LCD.
• The OPERATION lamp goes off.
AUTO · DRY · COOL · HEAT · FAN
Operation
NOTE
Notes on AUTO operation
• In AUTO operation, the system selects an appropriate operation mode (COOL or HEAT) based on the indoor temperature and starts the
operation.
• The system automatically reselects setting at a regular interval to bring the indoor temperature to the user-setting level.
Note on COOL operation
• This air conditioner cools the room by releasing the heat in the room outside.
Therefore, the cooling performance of the air conditioner may be degraded if the outdoor temperature is high.
Note on DRY operation
• Eliminates humidity while maintaining the indoor temperature as much as possible. It automatically controls temperature and airow rate, so
manual adjustment of these functions is unavailable.
Notes on HEAT operation
• Since this air conditioner heats the room by taking heat from outdoor air to indoors, the heating capacity becomes smaller in lower outdoor
temperatures. If the heating effect is insufcient, it is recommended to use another heating appliance in combination with the air conditioner.
• The heat pump system heats the room by circulating hot air around all parts of the room. After the start of HEAT operation, it takes some time
before the room gets warmer.
• In HEAT operation, frost may occur on the outdoor unit and lower the heating capacity. In that case, the system switches into defrosting
operation to take away the frost.
Note on FAN operation
• This mode is valid for fan only.

14
Basic Operation
To change the temperature setting
Press .
• Press to raise the temperature and press to lower the temperature.
Each pressing of the button changes the temperature by 0.5°C.
COOL
operation
HEAT
operation
AUTO
operation
DRY/FAN
operation
18.0~32.0°C 10.0~30.0°C 18.0~30.0°C The temperature setting
cannot be changed.
Tips for saving energy
Keeping the temperature setting at a moderate level helps save energy.
• Recommended temperature setting for cooling: 26.0-28.0°C, for heating: 20.0-24.0°C
Cover windows with a blind or a curtain.
• Blocking sunlight and air from outdoors increases the cooling (heating) effect.
Keep the air lters clean.
• Clogged air lters cause inefcient operation and waste energy. Clean them once in about every 2weeks. Page 39
If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn off the circuit
breaker.
• The air conditioner always consumes a small amount of electricity even while it is not operating.

15
Basic Operation
You can adjust the airow rate to increase your comfort.
To adjust the airow rate setting
Press .
• Each pressing of the button changes the airow rate setting in sequence.
AUTO Indoor unit quiet Airflow rate 1-5 (Low to High)
• When the airow is set to “ ”, quiet operation starts and noise from the indoor unit will
become quieter.
• In the quiet operation mode, the airow rate is set to a weak level.
• If the temperature dose not reach the desired point, change the airow rate setting.
• If COOL/DRY operation is started with airow settings on “AUTO”, the indoor unit will
initially deodorise, which functions to suppress any internal odours. As a result, the indoor
unit will not emit air immediately. (Wait for about 1 minute.)
• At smaller airow rates, the cooling (heating) effect is also smaller.
Adjusting the Airow Rate

16
Basic Operation
Adjusting the Airow Direction
You can adjust the airow direction to increase your comfort.
ATTENTION
• Always use a remote controller to adjust the angles of the aps and louvres.
− If you attempt to move the aps and louvres forcibly by hand when they are swinging, the mechanism
may be damaged.
− Inside the air outlet, a fan is rotating at a high speed.
To start auto swing
Up and down airow direction
Press .
• “ ” appears on the LCD.
• The aps (horizontal blades) will begin to swing.
Right and left airow direction
Press .
• “ ” appears on the LCD.
• The louvres (vertical blades) will begin to swing.
The 3-D airow direction
Press and .
• “ ” and “ ” appear on the LCD.
• The aps and louvres move in turn.
• To cancel 3-D airow, press either or again.
The aps or louvres will stop moving.
To set the aps or louvres at the desired position
• This function is effective while the aps or louvres are in auto swing mode.
Press and when the aps or louvres
reach the desired position.
• In the 3-D airow, the aps and louvres move in turn.
• “ ” or “ ” disappears from the LCD.
NOTE
Note on airow direction setting
• The movable range of the aps varies according to the operation mode.
Note on 3-D airow
• Using 3-D airow circulates cold air, which tends to collect at the bottom of the room,
and hot air, which tends to collect near the ceiling, throughout the room, preventing
areas of cold and hot developing.
COOL / DRY
FAN
HEAT
Movable range of the flaps

17
Useful Functions
MOLD PROOF Operation
The inside of the air conditioner is dried to reduce the occurrence of mold and odour.
When COOL or DRY operation is performed, condensation may occur inside the air
conditioner and may cause mold or odour. It is recommended to dry the inside of the
air conditioner using MOLD PROOF operation.
[To operate automatically]
To set
1. Press and hold the button for 2 seconds.
2. Press or and select menu number .
• “ ” appears on the LCD.
• “ ” (menu number) blinks.
3. Press to conrm the selected setting.
4. Press or to change the setting
as follows:
Automatic operation is disabled
(default)
Automatic operation is enabled
5. Press again.
• Automatic MOLD PROOF operation will be enabled or disabled according to
the chosen setting.
• If automatic MOLD PROOF operation is enabled, “ ” appears on the LCD and the MOLD
PROOF lamp lights green when MOLD PROOF operation is in progress.
• The STREAMER lamp lights green and ash streamer air cleaning operation starts.
Display
6. Press to return to the default screen.
NOTE
Note on MOLD PROOF setting
•
The display automatically returns to the default screen after 60 seconds. To return to the default screen sooner, press twice.
Notes on MOLD PROOF operation
• When you want to stop MOLD PROOF operation midway, press twice.
•
After DRY or COOL operation stops, the air conditioner starts MOLD PROOF operation automatically, and then stops automatically 60 minutes later.
• This operation dries the inside of the air conditioner while streamer discharge is performed to reduce the development of mold and odour
inside the air conditioner. But the function does not remove any adhered dust and mold.
• MOLD PROOF operation is not available when the unit is turned off using the OFF TIMER or turned off using a smartphone.

18
Useful Functions
NOTE
Notes on MOLD PROOF operation
• The aps may sometimes close to increase the drying effect inside the air conditioner.
• MOLD PROOF operation may not be performed if the COOL or DRY operation time is short.
• If MOLD PROOF operation does not suit your preference, set operation to “OFF”. Page 17
Relation between MOLD PROOF operation and indoor unit lamps
Air conditioner MOLD PROOF setting MOLD PROOF lamp STREAMER lamp
Operating
(OPERATION lamp lights up)
MOLD PROOF is “ON” Lights up Depends on STREAMER
setting
MOLD PROOF is “OFF” Goes off
Not operating
(OPERATION lamp goes off) MOLD PROOF is “ON” Lights up Lights up

19
Useful Functions
FLASH STREAMER AIR CLEANING
operation
The streamer generates a high-speed electron stream with a high oxidizing power,
reducing bad odours and viruses. Together with the deodorizing lter (enzyme blue)
and the air lters, this function cleans the air in the room.
To set
1. Press and hold the button for 2 seconds.
2. Press or and select menu number .
• “ ” appears on the LCD.
• “ ” (menu number) blinks.
3. Press to conrm the selected setting.
4.
Press or to change the setting as follows:
Streamer operation is enabled
(default)
Streamer operation is disabled
5. Press again.
• Flash streamer air cleaning will be enabled or disabled according to the chosen setting.
• If STREAMER operation is enabled, “ ” appears on the LCD.
The STREAMER lamp lights green and ash streamer air cleaning operation starts.
Display
6. Press to return to the default screen.
NOTE
What is streamer discharge?
• This is a type of plasma discharge comprising high-speed electrons with a high oxidative capacity that is released within the unit.
It decomposes odours and harmful gases. (The high-speed electrons are generated and then adsorbed within the unit ensure your safety.)
Note on ash streamer air cleaning setting
• The display automatically returns to the default screen after 60 seconds.
To return to the default screen sooner, press twice.
Notes on ash streamer air cleaning operation
• The streamer discharge may generate a zzing sound, however this does not indicate a defect.
• Do not block the air inlets of the streamer with any objects (Fig.1).
Impaired airow may result in insufcient performance or trouble with streamer operation.
Streamer
air inlets
Fig. 1

20
Useful Functions
NOTE
Notes on COMFORT AIRFLOW Operation
• POWERFUL operation and COMFORT AIRFLOW operation cannot be used at the same time.
• The airow rate will be set to AUTO.
• If the upward and downward airow direction is selected, the COMFORT AIRFLOW function will be canceled.
Priority is given to the function of whichever button is pressed last.
• If there is an obstruction under the air conditioner when using heating, the airow may not reach the center of the room and the room may be
difcult to warm up.
COMFORT AIRFLOW Operation
The ow of air will be in the upward direction while in COOL/DRY operation
and in the downward direction while in HEAT operation, which will provide a
comfortable wind that will not come in direct contact with people.
COOL and DRY operation
Airow direction : Upward
(ceiling spread airow)
HEAT operation
Airow direction : Downward
(oor spread airow)
To start
Press
Comfort
.
• “ ” appears on the LCD.
COOL and DRY
operation HEAT operation FAN operation
Flaps direction Goes up Goes down Not available
Airow rate AUTO
To cancel
Press
Comfort
again.
• “ ” disappears from the LCD.
• The aps will return to the position in memory from before COMFORT AIRFLOW operation.

21
Useful Functions
INTELLIGENT EYE Operation
The INTELLIGENT EYE sensor detects human movement and adjusts airow
direction. It can be set to avoid people or to direct airow specically at people.
If no one is in the room for more than 20 minutes, the operation automatically
changes to energy saving operation.
CAUTION
• Do not place large objects near the INTELLIGENT EYE sensor. Also keep heating units and humidiers
outside the sensor’s detection area. This sensor can detect undesirable objects.
• Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.
To start
Press
Sensor
and select the desired mode.
• Each time
Sensor
is pressed, a different setting option appears on the LCD.
blank
No SettingDo not blow
directly on people
Blow directly
on people
• If both INTELLIGENT EYE operation and auto swing airow directions (up and down or
right and left) are set simultaneously, priority is given to auto swing airow directions
and INTELLIGENT EYE operation will be operated in energy saving operation only.
( “ ” or “ ” will remain on the LCD.) To keep INTELLIGENT EYE operation active,
do not use it in combination with auto swing airow direction modes.
To cancel
Press
Sensor
until no icon is displayed.
NOTE
Notes on combining INTELLIGENT EYE operation and COMFORT AIRFLOW operation
• INTELLIGENT EYE operation can operate in combination with COMFORT AIRFLOW operation.
When the INTELLIGENT EYE operation is set to blow directly on people and COMFORT AIRFLOW operation is activated simultaneously,
the air conditioner tracks you horizontally, without the air blowing directly on you.
• The airow rate will be set to AUTO. If the up and down airow direction is selected, the COMFORT AIRFLOW operation will be canceled.
Priority is given to the function of whichever button is pressed last.

22
Useful Functions
INTELLIGENT EYE operation is useful for energy saving
Energy saving operation
• If no presence detected in the room for 20minutes, the energy saving operation will start.
• This operation changes the temperature by −2°C in HEAT / +2°C in COOL / +2°C in DRY operation from the set temperature.
When the room temperature exceeds 30°C, the operation changes the temperature by +1°C in COOL / +1°C in DRY operation from the
set temperature.
• This operation decreases the airow rate slightly in FAN operation only.
NOTE
Notes on INTELLIGENT EYE operation
• Application range is as follows.
90°
55°
5m
55°
Vertical angle 90°
(Side view)
Horizontal
angle 110°
(Top view)
5m
• While the air conditioner is in INTELLIGENT EYE operation, the louvres adjust the airow direction if there are people in the sensing areas of
the INTELLIGENT EYE so that the leftward or rightward airow will not be directed to the people.
If no people are detected in either area 1 or 2 for 20 minutes, the air conditioner switches to the energy-saving mode with the set temperature
shifted by 2°C.
The air conditioner may switch to the energy-saving operation even if there are people in the areas.
This may occur depending on the clothes the people are wearing, if there is no movement of the people in the areas.
• The airow direction from the louvres will be leftward if there are people in both areas 1 and 2. The air will also ow left if there is a person
right in front of the sensor as the sensor judges that there are people in both areas.
• Due to the position of the sensor, people might be exposed to the airow of the indoor unit if they are close to the front side of the indoor unit.
If there are people close to the front side of the indoor unit or in both areas, it is recommended to use the COMFORT AIRFLOW and
INTELLIGENT EYE operations simultaneously. Using both modes together, the air conditioner will not direct the airow towards the people.
• The sensor may not detect moving objects further than 5m away. (Please see the application range)
• Sensor detection sensitivity changes according to the indoor unit location, the speed of passers-by, temperature range, etc.
• The sensor could also mistakenly detect pets, sunlight, uttering curtains and light reected off of mirrors as passers-by.
• NIGHT SET mode Page 26 will not switch on during use of INTELLIGENT EYE operation.
How INTELLIGENT EYE operation works
The INTELLIGENT EYE sensor detects human movement and adjusts the right and left airow direction.
If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving
operation. The INTELLIGENT EYE sensor works differently depending on the situation.
[Example]
A person is detected in
area 1. area 2.
People are detected in
both areas.
No people are detected in
the areas.
Area 1 Area 2 Area 1 Area 2
Area 1 Area 2
The current airflow direction is
maintained.
The airflow is directed to Area 1.
The air conditioner will switch
to energy-saving mode after
20 minutes.
Area 1 Area 2 Area 1 Area 2
* The airflow direction may differ from the illustrated direction depending on the actions and movements of the people in the areas.
A person is detected in

23
Useful Functions
POWERFUL operation quickly maximises the cooling (heating) effect in any
operation mode. In this mode, the air conditioner operates at maximum capacity.
To start
Press during operation.
• “ ” appears on the LCD.
• POWERFUL operation ends in 20minutes. Then the system automatically operates again
with the previous settings which were used before POWERFUL operation.
To cancel
Press again.
• “ ” disappears from the LCD.
POWERFUL Operation
NOTE
Notes on POWERFUL operation
• Pressing causes the settings to be cancelled, and “ ” disappears from the LCD.
• POWERFUL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum
capacity demonstrated.
− In COOL, HEAT and AUTO operation
To maximise the cooling (heating) effect, the capacity of outdoor unit increases and the airow rate becomes xed at the maximum setting.
The temperature and airow settings cannot be changed.
− In DRY operation
The temperature setting is lowered by 2.5°C and the airow rate is slightly increased.
− In FAN operation
The airow rate is xed at the maximum setting.
Regarding the combination of POWERFUL and other operations
POWERFUL + COMFORT AIRFLOW
Not available*
*Priority is given to the function of whichever button is pressed last.
POWERFUL + ECONO
POWERFUL + OUTDOOR UNIT QUIET

24
Useful Functions
ECONO / OUTDOOR UNIT QUIET
Operation
ECONO operation enables efcient operation by limiting the maximum power
consumption. This function is useful to prevent the circuit breaker from tripping
when the unit operates alongside other appliances on the same circuit.
OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit
by changing the frequency and fan speed of the outdoor unit. This function is
convenient during the night-time operation.
To start
Press and select the desired mode.
• Each time is pressed, a different setting option appears on the LCD.
ECONO OUTDOOR UNIT
QUIET
blank
No SettingCombination
To cancel
Press until no icon is displayed.
NOTE
Notes on ECONO operation
• This operation is performed with lower power and therefore may not provide a sufcient cooling (heating) effect.
• Pressing causes the settings to be cancelled, and “ ” disappears from the LCD.
• If the power consumption level is already low, switching to ECONO operation will not reduce the power consumption.
Notes on OUTDOOR UNIT QUIET operation
• Even if the operation is stopped by using the remote controller or the indoor unit ON/OFF switch when using OUTDOOR UNIT QUIET
operation, “
” will remain displayed on the remote controller.
• OUTDOOR UNIT QUIET operation will not reduce the frequency nor fan speed if they already are operating at reduced levels.
• This operation is performed with lower power and therefore may not provide a sufcient cooling (heating) effect.
Possible combinations of ECONO / OUTDOOR UNIT QUIET operation and basic operations
Operation mode
AUTO DRY COOL HEAT FAN
ECONO –
OUTDOOR UNIT QUIET – –

25
TIMER Operation
ON/OFF TIMER Operation
Timer functions are useful for automatically switching the air conditioner on or off
at night or in the morning. You can also use the ON TIMER and OFF TIMER
together.
[ON TIMER with a 24 hour clock display]
(24 HOUR ON/OFF TIMER)
To set
• Check that the clock is correct.
If not, set the clock to the present time. Page 11
1. Press .
“ ” appears on the LCD.
“ ” blinks.
• “ ” and day of the week disappear from the LCD.
2. Press until the time setting reaches the
point you like.
• Each pressing of either button increases or decreases the time setting by 10minutes.
Holding down either button changes the setting rapidly.
3. Press again.
• “ ” and setting time appear on the LCD.
• The TIMER lamp lights orange.
Display
To cancel
Press .
• “ ” and setting time disappear from the LCD.
• “ ” and day of the week appear on the LCD.
• The TIMER lamp goes off.
NOTE
Note on TIMER operation
• When TIMER is set, the present time is not displayed.
In the following cases, set the timer again.
• After the circuit breaker has turned off.
• After a power failure.
• After replacing the batteries in the remote controller.

26
TIMER Operation
[OFF TIMER with a 24 hour clock display]
(24 HOUR ON/OFF TIMER)
To set
• Check that the clock is correct.
If not, set the clock to the present time. Page 11
1. Press .
“ ” appears on the LCD.
“ ” blinks.
• “ ” and day of the week disappear from the LCD.
2. Press until the time setting reaches the
point you like.
• Each pressing of either button increases or decreases the time setting by 10minutes.
Holding down either button changes the time setting rapidly.
3. Press again.
• “ ” and setting time appear on the LCD.
• The TIMER lamp lights orange.
Display
To cancel
Press .
• “ ” and setting time disappear from the LCD.
• “ ” and day of the week appear on the LCD.
• The TIMER lamp goes off.
[ON/OFF TIMER combination]
To combine
• A sample setting for combining the 2timers is shown below.
(Example)
Present time: 23:00 (The unit is operating)
OFF TIMER at 0:00
ON TIMER at 14:00 Combined
NOTE
NIGHT SET mode
• When the OFF TIMER is set, the air conditioner automatically adjusts the temperature setting (0.5°C up in COOL, 2.0°C down in HEAT) to
prevent excessive cooling (heating) during sleeping hours.

27
TIMER Operation
[ON/OFF TIMER with an hours remaining display]
(COUNT UP-DOWN ON/OFF TIMER)
• Check that the clock is correct. If not, set the clock to the present time. Page 11
1. Press and hold or for about
5 seconds, when signal indicater ( ) blink,
release your nger from the button.
For ON TIMER
“ ” appears on the LCD.
“ ” blinks.
For OFF TIMER
“ ” appears on the LCD.
“ ” blinks.
• “ ” and day of the week disappear from the LCD.
2. Press until the time setting reaches the
point you like.
• Each pressing of the button increases or decreases the time setting by 1 hour.
• The time can be set between 1 and 12 hours.
3. Press or again.
• “ ” and “ ”, and setting time appear on the LCD.
• The TIMER lamp lights orange.
•
To change the display mode from COUNT UP-DOWN ON/OFF TIMER to 24 HOUR ON/OFF
TIMER, repeat , and continue from of “24 HOUR ON/OFF TIMER”. STEP1 STEP2
Page 25, 26
• Timer display mode cannot be changed while “ ” or “ ” are blinking.
Press or to stop the blinking.
Display
Combining display modes
• Different display modes (24 HOUR ON/OFF TIMER and COUNT UP-DOWN ON/OFF TIMER)
can be used for the ON TIMER and OFF TIMER simultaneously.
(Example)
Present time: 22:00 (The unit is operating)
OFF TIMER at 1:00 (3 hours after persent time)
ON TIMER at 6:00 (8 hours after persent time) Combined
NOTE
Note on COUNT UP-DOWN ON/OFF TIMER
• After setting, the time displayed on the LCD will automatically count down by 1 hour for every 1 hour that passes.
For example, if the OFF TIMER is set to 3 hours, the display will change as follows: 3hr 2hr blank (OFF) 1hr
Switching between ON/OFF TIMER display modes (24 hour clock and hours remaining display)
• When changing timer display modes (from 24 HOUR ON/OFF TIMER to COUNT UP-DOWN ON/OFF TIMER or vice versa), the timer
cancels. The timer must be set again to activate it.
ON/OFF TIMER Operation

28
TIMER Operation
WEEKLY TIMER Operation
Up to 4 timer settings can be saved for each day of the week. This is convenient to adapt the WEEKLY
TIMER to your family’s life style.
Setting example of the WEEKLY TIMER
The same timer settings are used from Monday through Friday, while different timer settings are used for the weekend.
[Monday] Make timer settings for programmes 1-4. Page 29
6:00 8:30 17:30 22:00
25.0°C 27.0°C
ON ON OFFOFF
Programme 1 Programme 2 Programme 3 Programme 4
ON OFF ON OFF
[Tuesday]
to
[Friday]
Use the copy mode to make settings for Tuesday to Friday, because these settings are the same as
those for Monday. Page 31
6:00 8:30 17:30 22:00
25.0°C 27.0°C
Programme 1 Programme 2 Programme 3 Programme 4
ON OFF ON OFF
[Saturday] No timer settings
[Sunday] Make timer settings for programmes 1-4. Page 29
8:00 10:00 19:00 21:00
27.0°C 27.0°C25.0°C
ON ONOFFOFF
ON OFF OFF ON
Programme 1 Programme 2 Programme 3 Programme 4
• Up to 4reservations per day and 28reservations per week can be set using the WEEKLY TIMER. The effective use of the
copy mode simplies timer programming.
• The use of ON-ON-ON-ON settings, for example, makes it possible to schedule operating mode and set temperature
changes. Furthermore, by using OFF-OFF-OFF-OFF settings, only the turn off time of each day can be set. This will turn off
the air conditioner automatically if you forget to turn it off.

29
TIMER Operation
To use WEEKLY TIMER operation
Setting mode
• Make sure the day of the week and time are set.
If not, set the day of the week and time. Page 11
6:00 8:30 17:30 22:00
25.0°C 27.0°C
Programme 1 Programme 2 Programme 3 Programme 4
ON OFF ON OFF
[Monday]
Day and number ON/OFF Time Temperature
Setting Displays
1. Press .
• The day of the week and the reservation number of the current day will be displayed.
• 1to 4settings can be made per day.
2. Press to select the desired day of the week
and reservation number.
• Pressing changes the reservation number and the day of the week.
3. Press .
• The day of the week and reservation number will be set.
• “ ” and “ ” blink.
4. Press to select the desired mode.
• Pressing changes the “ ” or “ ” setting in sequence.
ON TIMER OFF TIMER
blank
No Setting
Pressing puts the sequence in reverse.
• In case the reservation has already been set, selecting “blank” deletes the reservation.
• Proceed to STEP9 if “blank” is selected.
• To return to the day of the week and reservation number setting, press .
5. Press .
• The ON/OFF TIMER mode will be set.
• “ ” and the time blink.
WEEKLY TIMER Operation

30
TIMER Operation
6. Press to select the desired time.
• The time can be set between 0:00 and 23:50 in 10-minute intervals.
• To return to the ON/OFF TIMER mode setting, press .
• Proceed to STEP 9 when setting the OFF TIMER.
7. Press .
• The time will be set.
• “ ” and the temperature blink.
8. Press to select the desired temperature.
• The temperature can be set between 10.0°C and 32.0°C.
COOL or AUTO: The unit operates at 18.0°C even if it is set to 10.0°C to 17.0°C. Page 14
HEAT or AUTO: The unit operates at 30.0°C even if it is set to 31.0°C to 32.0°C. Page 14
• To return to the time setting, press .
• The set temperature is only displayed when the mode setting is on.
9. Press .
• The temperature will be set and go to the next reservation setting.
• The temperature is set while in ON TIMER operation, and the time is set while in OFF
TIMER operation.
• The next reservation screen will appear.
• To continue further settings, repeat the procedure from STEP
4.
10.
Press to complete the setting.
• Be sure to direct the remote controller toward the indoor unit and check for a receiving
tone and blinking of the OPERATION lamp.
• “ ” appears on the LCD and WEEKLY TIMER operation is activated.
• The TIMER lamp lights orange.
Display
• A reservation made once can be easily copied and the same settings used for another
day of the week. Refer to Copy mode . Page 31
NOTE
Notes on WEEKLY TIMER operation
• Do not forget to set the clock on the remote controller rst. Page 11
• The day of the week, ON/OFF TIMER mode, time and set temperature (only for ON TIMER mode) can be set with the WEEKLY TIMER.
Other settings for the ON TIMER are based on the settings just before the operation.
• WEEKLY TIMER and ON/OFF TIMER operation cannot be used at the same time. The ON/OFF TIMER operation has priority if it is set while
WEEKLY TIMER is still active. The WEEKLY TIMER will enter the standby state, and “ ” will disappear from the LCD. When the ON/
OFF TIMER is up, the WEEKLY TIMER will automatically become active.
• Only the time and set temperature with the WEEKLY TIMER are sent with the . Set the WEEKLY TIMER only after setting the operation
mode, the airow rate and the airow direction ahead of time.
•
Turning off the circuit breaker, power failure, and other similar events will render operation of the indoor unit’s internal clock inaccurate. Reset the clock.
Page 11
• can be used only for the time and temperature settings. It cannot be used to go back to the reservation number.

32
TIMER Operation
Conrming a reservation
• The reservation can be conrmed.
Normal
Setting Displays
Conrmation
1. Press .
• The day of the week and the reservation number of the current day will be displayed.
2. Press to select the day of the week and the
reservation number to be conrmed.
• Pressing displays the reservation details.
•
To change the conrmed reserved settings, select the reservation number and press .
The mode is switched to setting mode. Proceed to Setting mode STEP 4. Page 29
3. Press to exit the conrmation mode.
• “” appears on the LCD and WEEKLY TIMER operation is activated.
• The TIMER lamp lights orange.
Display
To deactivate WEEKLY TIMER operation
Press while “ ” is displayed on the
LCD.
• “ ” disappears from the LCD.
• The TIMER lamp goes off.
• To reactivate the WEEKLY TIMER operation, press again.
• If a reservation deactivated with is activated once again, the last reservation mode
will be used.
NOTE
• If not all the reservation settings are reected, deactivate the WEEKLY TIMER operation once. Then press again to reactivate the
WEEKLY TIMER operation.

33
TIMER Operation
To delete a reservation
An individual reservation
1. Press .
• The day of the week and the reservation number will be displayed.
2. Press to select the day of the week and the
reservation number to be deleted.
3. Press .
• “ ” and “ ” or “ ” blink.
4. Press until no icon is displayed.
• Pressing changes the ON/OFF TIMER mode in sequence.
• Selecting “blank” will cancel any reservation you may have.
ON TIMER OFF TIMER
blank
No Setting
Pressing puts the sequence in reverse.
5. Press .
• The selected reservation will be deleted.
6. Press .
• If there are still other reservations, WEEKLY TIMER operation will be activated.
Reservations for each day of the week
• This function can be used for deleting reservations for each day of the week.
• It can be used while conrming or setting reservations.
1. Press .
• The day of the week and the reservation number will be displayed.
2.
Press to select the day of the week to be deleted.
3. Hold for about 5seconds.
• The reservation of the selected day of the week will be deleted.
4. Press .
• If there are still other reservations, WEEKLY TIMER operation will be activated.
All reservations
Hold for about 5seconds with the normal display.
•
Be sure to direct the remote controller toward the indoor unit and check for a receiving tone.
• This operation cannot be used for the WEEKLY TIMER setting display.
• All reservations will be deleted.
WEEKLY TIMER Operation

34
System control via Smart Control
Wireless LAN connection
Please note
• Turn off the air conditioner before setting up wireless connection.
Prior to setting up, please make sure your device is ready to connect. You may refer to the indoor
unit LED table for guidance.
Check the indoor unit LED.
Wireless LAN connecting adapter lamp Status
Blinks for one second • The wireless LAN connecting adapter is ready to
connect.
No blinking/no light
• The wireless LAN connecting adapter is disabled.
• Malfunction in communication between the indoor unit
and the wireless LAN connecting adapter.
Please refer to the troubleshooting guide or contact
the store where you bought the air conditioner to
request a repair service.
Lamp stays lit • The wireless LAN connecting adapter is connected to
a modem/router.
Wireless LAN connecting
adapter lamp (Orange)
Display
Wireless LAN connection
Web site: http://www.daikinthai.com/product/dmobile
For more information on the latest version of wireless LAN control, please refer to the above website.
Application software installation
•
Before downloading the application software for installation, please read ‘‘Conguration” on
Page 7
.
For Android phones
1) Open [Google Play].
2) Search using the application name: [DAIKIN Mobile Controller].
3) Follow the on-screen instructions for installation.
For iOS phones
1) Open [App Store].
2) Search using the application name: [DAIKIN Mobile Controller].
3) Follow the on-screen instructions for installation.
Setting
Connect the wireless LAN connecting adapter to your home network.
• The wireless LAN connecting adapter will communicate with the smart devices in your home
network via a modem, router, or a similar device.
There are two options for connecting the wireless LAN connecting adapter to your smart phone or tablet:
1) Simple connection (WPS connection), if there is a WPS button on the router, Page 36 .
2) Access point connection (AP connection), if there is no WPS button on the router,
Page 37
.
For more information and Frequently Asked Questions, please refer to:
http://www.daikinthai.com/product/dmobile
NOTE
Note on wireless LAN connection
• For more information on how the wireless LAN connecting adapter operates, please see Page 35-37 .
WPS SETUP
Wi-Fi PROTECTED

35
System control via Smart Control
Enabling/disabling the wireless LAN connecting adapter
To enable
1. While operation is stopped, press and hold
the button for 5 seconds.
• “ ” appears on the LCD.
• “ ” (SP menu) blinks.
2. Press or and select SP menu .
3. Press to conrm the selected setting.
• “ ” blinks briey.
• The wireless LAN connecting adapter
lamp (orange) blinks for one second.
4. Press to return to the default screen.
To disable
1. While operation is stopped, press and hold
the button for 5 seconds.
• “ ” appears on the LCD.
• “ ” (SP menu) blinks.
2. Press or and select SP menu .
3. Press and hold for 2 seconds to conrm
the selected setting.
• “ ” blinks briey.
• The wireless LAN connecting adapter
lamp (orange) goes off.
4. Press to return to the default screen.
Wireless LAN connection
Display

37
System control via Smart Control
NOTE
Note on access point connection (AP connection)
• If you fail to connect (the wireless LAN connecting adapter lamp (orange) continues to blink), repeat steps 1-2.
Access point connection (AP connection).
If your home Wi-Fi router does not have a WPS button, you can connect your smart phone directly to the
wireless LAN connecting adapter in order to set up a connection to your home network by following these steps.
− This step requires SSID number and KEY located on the indoor unit or on the cover of the manual.
1.
Connect the wireless LAN connecting adapter to a smart phone or tablet.
View available Wi-Fi networks on your smart phone or tablet and connect to the SSID (DaikinAP*****) printed out on
the sticker. SSID and KEY are located on the indoor unit or on the cover of the manual, as shown in the below image.
[Sticker attachment area]
Attach the SSID&KEY sticker of wireless LAN connecting
adapter to the sti er attachment area and ck keep safe.
DAI K R C O O RIN O OM AIR NDI TI NE
O AT N UALPER IO MAN
中文 (繁體)English
•
Sticker on the indoor unit
SSID&KEY sticker •
Sticker on the cover of the manual
2.
Open the DAIKIN Mobile Controller application and select
“Congure the wireless connection” (Fig. 2) and connect to
your home network as per the on-screen instructions.
•
The wireless LAN connecting adapter lamp (orange) stays lit. If you fail to connect, refer to NOTE.
3.
Connect your smart phone to your home network.
4.
Open the Home screen of the DAIKIN Mobile Controller
application. The air conditioner will be listed there.
Reset connection setting to factory defaults.
Please note
When the device is reset, out-of-home user account and wireless LAN connection setting will be changed back to the factory defaults.
To reset
1. While operation is stopped, press and hold
the button for 5 seconds.
• “ ” appears on the LCD.
• “ ” (SP menu) blinks.
2. Press or and select SP menu .
3.
Press and hold for 2 seconds to conrm the selected setting.
• “ ” blinks briey.
•
The wireless LAN connecting adapter lamp (orange) blinks for one second.
4.
Press to return to the default screen.
Wireless LAN connection
Display
Fig. 2

39
Care
Air lter
1. Open the front panel.
• Hold the front panel by the sides and open it.
Backside of the front panel
Fixing tab
Panel support plate
2. Pull out the air lters.
• Push the lter tab at the centre of each air lter a
little upwards, then pull it down.
1) Push
2) Pull down
3. Wash the air lters with
water or clean them with
vacuum cleaner.
• It is recommended to clean the air lters every
2weeks.
If the dust does not come off easily
• Wash the air lters with neutral detergent thinned with
lukewarm water, then dry them up in the shade.
• Be sure to remove the lter (small).
Refer to “ ” on the next page.Filter (small)
4. Reattach the lters.
5. Close the front panel slowly.
• Press the panel at both sides and the centre.
• Make sure that the front panel is securely xed.
Care and Cleaning

40
Care
Filter (small)
* For the applicable lter type, please refer to Page 38 .
Attaching
1. Open the front panel and
pull out the air lters.
Page 39
2. Insert the lter.
•
Check that the lters are inserted securely under the tabs.
Air lters
Filter (small)
Filter frame
Tab
Claw
Cleaning and Replacement
1. Open the front panel and
pull out the air lters.
Page 39
2. Take off the lter.
• Hold the recessed parts of the frame and
unhook the 4 claws.
• Remove the lters from the tabs.
Air lters
Filter (small)
Filter frame
Tab
Claw
3. Clean or replace.
[Cleaning]
Deodorizing lter (enzyme blue) : Blue
/ Titanium apatite deodorizing lter :
Blue-Black
3-1 Vacuum dust, and soak in lukewarm
water or water for about 10 to
15minutes if very dirty.
3-2 After washing, shake off remaining
water and let them dry in the shade.
• This lter can be renewed by washing it with water
once and we recommend every 6 months
replacing it once every 3 years.
•
Do not wiring out the lter when removing water from it.
Air quality lter (enzyme blue with
PM2.5) : Blue-White/ Dust collection
lter (PM 2.5) : White
•
Do not wash the lters as this will reduce their efciency.
•
It is recommended to replace it once every 6 months.
[Replacement]
Remove the lter from the lter
frame and prepare a new one.
• Do not throw away the lter frame.
• Reuse the lter frame when replacing the lter.
• When attaching the lter, check that the lter is
properly set in the tabs.
4. Set the lters as they were
and close the front panel.
• Press the front panel at both sides and the center.
NOTE
• Operation with dirty lters:
− cannot deodorise the air,
− cannot clean the air,
− results in poor heating or cooling,
− may cause odour.
• Dispose of old lters as non-ammable waste.

42
When the Need Arises
FAQ
Indoor unit
Outdoor unit
• The appearance of the outdoor unit may differ between different models.
The air conditioner stops generating
airow during HEAT operation.
• Once the set temperature is reached, the airow rate is
reduced and operation stopped in order to avoid
generating a cool airow. Operation will resume
automatically when the indoor temperature falls.
The aps do not start swinging
immediately.
• The air conditioner is adjusting the position of the aps.
The aps will start moving soon.
Commonly occurring sounds.
A sound like owing water
• This sound is generated because the refrigerant in
the air conditioner is owing.
• This is a pumping sound of the water in the air
conditioner and can be heard when the water is
pumped out from the air conditioner during COOL or
DRY operation.
• This sound is generated during COOL operation on
outdoor ambient lower than 12°C when outdoor fan
stop for keep pressure.
Blowing sound
• This sound is generated when the ow of the
refrigerant in the air conditioner is switched over.
Ticking sound
• This sound is generated when the cabinet and
frame of the air conditioner slightly expand or shrink
as a result of temperature changes.
Whistling sound
• This sound is generated when refrigerant ows
during defrosting operation.
Clicking sound during operation or idle time
• This sound is generated when the refrigerant control
valves or the electrical parts operate.
Clopping sound
•
This sound is heard from the inside of the air conditioner
when the exhaust fan is activated while the room doors
are closed. Open the window or turn off the exhaust fan.
Hissing/Cracking sound
•
The sound of the streamer discharge.
It is not a malfunction.
The outdoor unit emits water or steam.
In HEAT operation
• The frost on the outdoor unit melts into water or steam when the air
conditioner is in defrosting operation.
In COOL or DRY operation
• Moisture in the air condenses into water on the cool surface of the outdoor
unit piping and drips.
HEAT operation stops suddenty and
a owing sound is heard.
• The outdoor unit is defrosting. HEAT operation starts
after the frost on the outdoor unit has been removed.
This can take about 4 to 12 minutes.
Operation does not start soon.
When was pressed soon after operation
was stopped.
When the mode was reselected.
• This is to protect the air conditioner.
You should wait for about 3 minutes.

43
When the Need Arises
The air conditioner does not operate
Case Description / what to check
OPERATION lamp is off.
• Has the circuit breaker been tripped or the fuse blown?
• Is there a power failure?
• Are batteries set in the remote controller?
OPERATION lamp is blinking.
•
Turn off the power with the circuit breaker and restart operation with the remote controller.
If the OPERATION lamp is still blinking, check the error code and consult your dealer.
Page 46
The air conditioner suddenly stops operating
Case Description / what to check
OPERATION lamp is on. • To protect the system, the air conditioner may stop operating after sudden large voltage
uctuations. It automatically resumes operation in about 3 minutes.
OPERATION lamp is blinking.
• Is there anything blocking the air inlet or air outlet of the indoor unit or outdoor unit?
Stop operation and after turning off the circuit breaker, remove the obstruction. Then restart
operation with the remote controller. If the OPERATION lamp is still blinking, check the error
code and consult your dealer.
The air conditioner does not stop operating
Case Description / what to check
The air conditioner continues
operating even after operation is
stopped.
Immediately after the air conditioner is stopped
• The outdoor unit fan continues rotating for about another 1 minute to protect the system.
While the air conditioner is not in operation
• When the outdoor temperature is high, the outdoor unit fan may start rotating to protect
the system.
• MOLD PROOF operation is being performed.
It is possible to stop MOLD PROOF operation while it is in progress.
(If this does not suit your preferences, set MOLD PROOF to “Off”.)
The room does not cool down/warm up
Case Description / what to check
Air does not come out.
In HEAT operation
• The air conditioner is warming up. Wait for about 1 to 4 minutes.
• During defrosting operation, hot air does not ow out of the indoor unit.
In COOL or DRY operation
• If COOL/DRY operation is started with airow settings on “AUTO”, the indoor unit will
initially deodorise, which functions to suppress any internal odours. As a result, the indoor
unit will not emit air immediately. (Wait for about 1 minute.)
When the air conditioner operates immediately after the circuit breaker is turned on
• The air conditioner is preparing to operate. Wait for about 3 to 15 minutes.
Air does not come out /
Air comes out.
Is the airow rate setting appropriate?
• Is the airow rate setting low, such as “Indoor unit quiet” or “Airow rate 1”?
Increase the airow rate setting.
Is the set temperature appropriate?
Is the adjustment of the airow direction appropriate?
Air comes out.
• Is there any furniture directly under or beside the indoor unit?
•
Is the air conditioner in ECONO operation or OUTDOOR UNIT QUIET operation?
Page 24
• Are the air lters dirty?
• Is there anything blocking the air inlet or air outlet of the indoor unit or outdoor unit?
• Is a window or door open?
• Is an exhaust fan turning?
The room temperature does not
reach the set temperature.
• If the air coming out of the air conditioner is blowing against a wall, the set temperature may
not be reached correctly.
Page 46
Troubleshooting
Before making an inquiry or a request for repair, please check the following.
If the problem persists, consult your dealer.
Air conditioner
Not a problem
This case is not a problem.
Check
Please check again before requesting repairs.

44
When the Need Arises
Mist comes out
Case Description / what to check
Mist comes out of the indoor unit. • This happens when the air in the room is cooled into mist by the cold airow during COOL
or other operation.
Remote controller
Case Description / what to check
The unit does not receive signals
from the remote controller or has
a limited operating range.
•
The batteries may be exhausted. Replace both batteries with new dry batteries AAA.LR03 (alkaline).
For details, refer to “Preparation Before Operation”. Page 10
• Signal communication may be disabled if an electronic-starter-type uorescent lamp
(such as inverter-type lamps) is in the room. Consult your dealer if that is the case.
•
The remote controller may not function correctly if the transmitter is exposed to direct sunlight.
LCD is faint, is not working,
or the display is erratic.
•
The batteries may be exhausted. Replace both batteries with new dry batteries AAA.LR03 (alkaline).
For details, refer to “Preparation Before Operation”. Page 10
The LCD is blinking and the
remote controller cannot be
operated.
• Battery power has run out.
Replace both batteries at the same time with new size AAA.LR03 (alkaline) batteries.
Leaving exhausted batteries in the remote controller can result in injury due to battery
leakage, rupturing or heating, or lead to equipment failure.
(Even when the LCD is blinking, the OFF button remains functional.)
Other electric devices start operating.
•
If the remote controller activates other electric devices, move them away or consult your dealer.
Air has an odour
Case Description / what to check
The air conditioner gives off
an odour.
• The room odour absorbed in the unit is discharged with the airow.
We recommend that you have the indoor unit cleaned. Please consult your dealer.
• Due to streamer discharge, the air outlet may emit a slight odour as trace amounts of ozone
are generated. However, the amount is negligible and is not harmful to your health.
Display lamps
Case Description / what to check
The OPERATION lamp is off,
but the air conditioner is
operating.
• Is the display brightness set to “Off”?
• MOLD PROOF operation is being performed.
It is possible to stop MOLD PROOF operation while it is in progress.
(If this does not suit your preferences, set MOLD PROOF to “Off”.)
The display lamps on the main
unit are dark.
• Is the display brightness set to “Low”?
Streamer air cleaning operation
Case Description / what to check
The sound of streamer discharge
can no longer be heard.
• If the airow becomes weak, the streamer discharge stops.
Others
Case Description / what to check
The air conditioner suddenly
starts behaving strangely during
operation.
• The air conditioner may malfunction due to lightning or radio.
If the air conditioner malfunctions, turn off the power with the circuit breaker and restart the
operation with the remote controller.
The ON/OFF TIMER does not
operate according to the settings.
• Check if the ON/OFF TIMER and the WEEKLY TIMER are set to the same time.
Change or deactivate the settings in the WEEKLY TIMER. Page 28,29,30
NOTE
Note on the operating conditions
• If operation continues under any conditions other than those listed in the table,
− A safety device may activate to stop the operation.
− Dew may form on the indoor unit and drip from it when COOL or
DRY operation is selected.
Air conditioner
Mode Operating conditions
COOL / DRY
Outdoor temperature: –10.0~46.0°C
Indoor temperature: 18.0~32.0°C
Indoor humidity: 80% max.
HEAT Outdoor temperature: –15.0~24.0°C
Indoor temperature: 10.0~30.0°C

46
When the Need Arises
Fault diagnosis by remote controller
• In case the air conditioner is malfunctioning, you can check the error code via the remote
controller before consulting with service personnel and informing them of the malfunction
code.
1. When is held down for about 5 seconds,
“ ” blinks in the temperature display section.
2. Press repeatedly until a long beep is
produced.
• The code indication changes as shown below, and noties you with a long beep.
CODE MEANING
SYSTEM
00 NORMAL
UA INDOOR-OUTDOOR UNIT COMBINATION FAULT
U0 REFRIGERANT SHORTAGE
U2 DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE
U4 FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT)
INDOOR
UNIT
A1 INDOOR PCB DEFECTIVENESS
A5 HIGH PRESSURE CONTROL OR FREEZE-UP PROTECTOR
A6 FAN MOTOR FAULT
C4 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
C9 FAULTY SUCTION AIR TEMPERATURE SENSOR
CC FAULTY HUMIDITY SENSOR
OUTDOOR
UNIT
EA COOLING-HEATING SWITCHING ERROR
E1 CIRCUIT BOARD FAULT
E5 OL STARTED
E6 FAULTY COMPRESSOR START UP
E7 DC FAN MOTOR FAULT
F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL
F6 HIGH PRESSURE CONTROL (IN COOLING)
F8 OPERATION HALT DUE TO COMPRESSOR INTERNAL TEMPERATURE
H0 SENSOR FAULT
H6 OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR
H8 DC CURRENT SENSOR FAULT
H9 FAULTY SUCTION AIR TEMPERATURE SENSOR
J3 FAULTY DISCHARGE PIPE TEMPERATURE SENSOR
J6 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
J8 FAULTY LIQUID PIPE TEMPERATURE SENSOR
L3 ELECTRICAL PARTS HEAT FAULT
L4 HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK
L5 OUTPUT OVERCURRENT
P4 FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR
NOTE
• A short beep and 2 consecutive beeps indicate non-corresponding codes.
• To cancel the code display, hold down for about 5 seconds. The code display also clears if no button is pressed for 1 minute.

The two-dimensional bar code is
a manufacturing code.
3P683779-3 M22N003 (2203) HT
Quick Reference
MODE
On/OffFAN
Temp
Mode
Swing

[Sticker attachment area]
Attach the SSID&KEY sticker of wireless LAN connecting
adapter to the sticker attachment area and keep safe.
DA IKI N R OOM AI R C OND ITI ONER
OPERATION MANUAL
MO DEL S
FTXM50W1VMA
FTXM60W1VMA
FTXM71W1VMA

3
Read Before Operation
Safety Precautions
Read the precautions in this manual carefully
before operating the unit. This appliance is lled with R32.
• Keep this manual where the user can easily nd it.
• The precautions described herein are classied as WARNING and CAUTION. They both contain important information regarding
safety. Be sure to observe all precautions without fail.
WARNING Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION Failure to observe these instructions properly may result in property damage or personal injury,
which may be serious depending on the circumstances.
Never attempt. Be sure to follow the
instructions.
Be sure to establish an earth
connection.
• After reading, keep this manual in a convenient place so that you can refer to it whenever necessary. If the equipment is
transferred to a new user, be sure also to hand over the manual.
WARNING
• Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
• The appliance must be stored in a room without continuously operating ignition sources (for example: open ames, an
operating gas appliance or an operating electric heater).
• Do not pierce or burn.
• Be aware that refrigerants may not contain an odour.
• The appliance must be installed, operated and stored in a room with oor area larger than –*m 2 for 20/25/35/46 class.
*
Since the maximum refrigerant charge of the models is below 1.84kg, it does not have any limitation for the minimum oor area.
Maintain an installation height of 1.8m or more from the oor surface to the bottom of the appliance.
• To avoid re, explosion or injury, do not operate the unit when harmful gases (e.g. ammable or corrosive) are detected near
the unit.
• Be aware that prolonged, direct exposure to cool or warm air from the air conditioner, or to air that is too cool or too warm,
can be harmful to your physical condition and health.
• Do not place objects, including rods, your ngers, etc., in the air inlet or outlet. Product damage or personal injury may
result due to contact with the air conditioner’s high-speed fan blades.
• Do not attempt to repair, dismantle, reinstall or modify the air conditioner yourself as this may result in water leakage,
electric shock or re hazards.
• Do not use ammable spray near the air conditioner, or otherwise re may result.
• Do not use a refrigerant other than the one indicated on the outdoor unit (R32) when installing, moving or repairing. Using
other refrigerants may cause trouble or damage to the unit, and personal injury.
• To avoid electric shock, do not operate with wet hands.
• Beware of re in case of refrigerant leakage. If the air conditioner is not operating correctly, i.e. not generating cool or warm
air, refrigerant leakage could be the cause. Consult your dealer for assistance. The refrigerant within the air conditioner is
safe and normally does not leak.
However, in the event of a leakage, contact with a naked burner, heater or cooker may result in generation of noxious gas.
Do not use the air conditioner until a qualied service person conrms that the leakage has been repaired.
• Do not attempt to install or repair the air conditioner yourself. Improper workmanship may result in water leakage, electric
shock or re hazards. Please contact your local dealer or qualied personnel for installation and maintenance work.
• If the air conditioner is malfunctioning (giving off a burning odour, etc.), turn off power to the unit and contact your local
dealer. Continued operation under such circumstances may result in a failure, electric shock or re hazards.
• Be sure to install an earth leakage circuit breaker. Failure to install an earth leakage circuit breaker may result in electric shock
or re.
• Be sure to earth the unit. Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead.
Imperfect earthing may result in electric shock.
CAUTION
• Do not use the air conditioner for purposes other than those for which it is intended. Do not use the air conditioner for
cooling precision instruments, food, plants, animals or works of art as this may adversely affect the performance, quality
and/or longevity of the object concerned.
• Do not expose plants or animals directly to the airow from the unit as this may cause adverse effects.
• Do not place appliances that produce naked ames in places exposed to the airow from the unit as this may impair
combustion of the burner.
• Do not block the air inlets nor outlets. Impaired airow may result in insufcient performance or trouble.
Produkt Specifikationer
Mærke: | Daikin |
Kategori: | Klimaanlæg |
Model: | Alira X FTKM35WVMA |
Har du brug for hjælp?
Hvis du har brug for hjælp til Daikin Alira X FTKM35WVMA stil et spørgsmål nedenfor, og andre brugere vil svare dig
Klimaanlæg Daikin Manualer

18 Februar 2025

18 Februar 2025

10 Februar 2025

10 Februar 2025

10 Februar 2025

10 Februar 2025

10 Februar 2025

10 Februar 2025

10 Februar 2025

15 Januar 2025
Klimaanlæg Manualer
- Klimaanlæg DeLonghi
- Klimaanlæg Bosch
- Klimaanlæg Sencor
- Klimaanlæg TCL
- Klimaanlæg Zibro
- Klimaanlæg Siemens
- Klimaanlæg Day
- Klimaanlæg Samsung
- Klimaanlæg Wilfa
- Klimaanlæg GE
- Klimaanlæg Zanussi
- Klimaanlæg CyberPower
- Klimaanlæg Panasonic
- Klimaanlæg Gorenje
- Klimaanlæg Tectro
- Klimaanlæg VOX
- Klimaanlæg Concept
- Klimaanlæg OK
- Klimaanlæg LG
- Klimaanlæg AEG
- Klimaanlæg Electrolux
- Klimaanlæg Bauknecht
- Klimaanlæg Whirlpool
- Klimaanlæg Mitsubishi
- Klimaanlæg Master
- Klimaanlæg Sharp
- Klimaanlæg Hotpoint
- Klimaanlæg Melissa
- Klimaanlæg ARGO
- Klimaanlæg Qlima
- Klimaanlæg Daewoo
- Klimaanlæg Korona
- Klimaanlæg Arçelik
- Klimaanlæg Soler & Palau
- Klimaanlæg Sanyo
- Klimaanlæg Baxi
- Klimaanlæg Grundig
- Klimaanlæg Progress
- Klimaanlæg Hotpoint Ariston
- Klimaanlæg Livoo
- Klimaanlæg Toshiba
- Klimaanlæg Klarstein
- Klimaanlæg Furrion
- Klimaanlæg Infiniton
- Klimaanlæg Trisa
- Klimaanlæg Matsui
- Klimaanlæg Nedis
- Klimaanlæg Emerio
- Klimaanlæg Bartscher
- Klimaanlæg Be Quiet!
- Klimaanlæg Sauber
- Klimaanlæg Westinghouse
- Klimaanlæg Element
- Klimaanlæg Thomson
- Klimaanlæg Hyundai
- Klimaanlæg AKAI
- Klimaanlæg Hisense
- Klimaanlæg TriStar
- Klimaanlæg Brandt
- Klimaanlæg Adler
- Klimaanlæg Camry
- Klimaanlæg Dometic
- Klimaanlæg Eurom
- Klimaanlæg TecLime
- Klimaanlæg Trotec
- Klimaanlæg Blaupunkt
- Klimaanlæg Einhell
- Klimaanlæg Becken
- Klimaanlæg BEKO
- Klimaanlæg Honeywell
- Klimaanlæg Clatronic
- Klimaanlæg Hitachi
- Klimaanlæg Rowenta
- Klimaanlæg Noveen
- Klimaanlæg Ariston Thermo
- Klimaanlæg Haier
- Klimaanlæg Truma
- Klimaanlæg Bomann
- Klimaanlæg Innoliving
- Klimaanlæg Zelmer
- Klimaanlæg Vivax
- Klimaanlæg Thermex
- Klimaanlæg Vaillant
- Klimaanlæg Alaska
- Klimaanlæg Zanker
- Klimaanlæg Galanz
- Klimaanlæg Amana
- Klimaanlæg Amcor
- Klimaanlæg Carrier
- Klimaanlæg Comfee
- Klimaanlæg Gree
- Klimaanlæg Dimplex
- Klimaanlæg Tripp Lite
- Klimaanlæg Primo
- Klimaanlæg Orbegozo
- Klimaanlæg Malmbergs
- Klimaanlæg Sigma
- Klimaanlæg Koenig
- Klimaanlæg Taurus
- Klimaanlæg Xiaomi
- Klimaanlæg Exquisit
- Klimaanlæg HQ
- Klimaanlæg Proklima
- Klimaanlæg Elba
- Klimaanlæg Air Breeze
- Klimaanlæg Fujitsu
- Klimaanlæg Inventor
- Klimaanlæg MPM
- Klimaanlæg Toyotomi
- Klimaanlæg Frigor
- Klimaanlæg TOSOT
- Klimaanlæg APC
- Klimaanlæg Domo
- Klimaanlæg Ferroli
- Klimaanlæg Saunier Duval
- Klimaanlæg Heylo
- Klimaanlæg Olimpia Splendid
- Klimaanlæg Aspes
- Klimaanlæg Eden
- Klimaanlæg Blumfeldt
- Klimaanlæg Inventum
- Klimaanlæg Altech
- Klimaanlæg Carson
- Klimaanlæg Fakir
- Klimaanlæg White Knight
- Klimaanlæg Dantherm
- Klimaanlæg Khind
- Klimaanlæg Midea
- Klimaanlæg Frigidaire
- Klimaanlæg Frilec
- Klimaanlæg Evolar
- Klimaanlæg Ridgid
- Klimaanlæg Ardes
- Klimaanlæg Suntec
- Klimaanlæg SVAN
- Klimaanlæg Everglades
- Klimaanlæg Danby
- Klimaanlæg RCA
- Klimaanlæg ECG
- Klimaanlæg General Electric
- Klimaanlæg Eldom
- Klimaanlæg H.Koenig
- Klimaanlæg Sonnenkönig
- Klimaanlæg Termozeta
- Klimaanlæg OneConcept
- Klimaanlæg Stirling
- Klimaanlæg Just Fire
- Klimaanlæg Be Cool
- Klimaanlæg Duux
- Klimaanlæg ElectriQ
- Klimaanlæg Kalorik
- Klimaanlæg Cecotec
- Klimaanlæg Airwell
- Klimaanlæg Anslut
- Klimaanlæg MundoClima
- Klimaanlæg Jocca
- Klimaanlæg Orima
- Klimaanlæg SereneLife
- Klimaanlæg Remko
- Klimaanlæg Friedrich
- Klimaanlæg Whynter
- Klimaanlæg Bestron
- Klimaanlæg Philco
- Klimaanlæg Fuave
- Klimaanlæg Avidsen
- Klimaanlæg Climadiff
- Klimaanlæg Kogan
- Klimaanlæg Ravanson
- Klimaanlæg Airlux
- Klimaanlæg Jocel
- Klimaanlæg Ufesa
- Klimaanlæg Keystone
- Klimaanlæg ActronAir
- Klimaanlæg Orava
- Klimaanlæg NewAir
- Klimaanlæg IFB
- Klimaanlæg Create
- Klimaanlæg Daitsu
- Klimaanlæg Daizuki
- Klimaanlæg Profile
- Klimaanlæg AireMax
- Klimaanlæg Aconatic
- Klimaanlæg Aermec
- Klimaanlæg Acson
- Klimaanlæg Andrews
- Klimaanlæg Akira
- Klimaanlæg Aircooler
- Klimaanlæg Airview
- Klimaanlæg Aertesi
- Klimaanlæg Royal Sovereign
- Klimaanlæg Alberello
- Klimaanlæg Salton
- Klimaanlæg Haverland
- Klimaanlæg Rasonic
- Klimaanlæg Mabe
- Klimaanlæg Heinner
- Klimaanlæg Nabo
- Klimaanlæg AlpicAir
- Klimaanlæg Kelvinator
- Klimaanlæg Tatung
- Klimaanlæg Milectric
- Klimaanlæg Lloyd
- Klimaanlæg Alpatec
- Klimaanlæg Godrej
- Klimaanlæg Maiko
- Klimaanlæg Aircool
- Klimaanlæg Igenix
- Klimaanlæg Edgestar
- Klimaanlæg Maxicool
- Klimaanlæg Argoclima
- Klimaanlæg Home Electric
- Klimaanlæg Teco
- Klimaanlæg Tarrington House
- Klimaanlæg Gutfels
- Klimaanlæg Telair
- Klimaanlæg Klarbach
- Klimaanlæg Mobile Airco
- Klimaanlæg Heiko
- Klimaanlæg Qlima - Zibro
- Klimaanlæg VänEE
- Klimaanlæg Handson
- Klimaanlæg Bryant
- Klimaanlæg Klima1stKlaas
- Klimaanlæg Emmeti
- Klimaanlæg Evapolar
- Klimaanlæg Ausclimate
- Klimaanlæg ARCTIC WIND
- Klimaanlæg Perfect Aire
- Klimaanlæg Black Decker
- Klimaanlæg TechnoLife
- Klimaanlæg Shinco
- Klimaanlæg Innova
- Klimaanlæg D-Let
- Klimaanlæg Domair
- Klimaanlæg General
- Klimaanlæg SEEGER
- Klimaanlæg Thermo Comfort
- Klimaanlæg Mizushi
- Klimaanlæg Sinclair
- Klimaanlæg Arcoaire
- Klimaanlæg Zymbo
- Klimaanlæg GoldAir
- Klimaanlæg Saneo
- Klimaanlæg Columbia Vac
- Klimaanlæg Kostal
- Klimaanlæg SMD
- Klimaanlæg Commercial Cool
- Klimaanlæg Coolix
- Klimaanlæg Omega Altise
- Klimaanlæg Koldfront
- Klimaanlæg Yamazen
- Klimaanlæg Corona
- Klimaanlæg Symphony
- Klimaanlæg Universal Blue
- Klimaanlæg Air&Me
- Klimaanlæg Onix
Nyeste Klimaanlæg Manualer

28 Marts 2025

27 Marts 2025

17 Marts 2025

17 Marts 2025

14 Marts 2025

6 Marts 2025

3 Marts 2025

3 Marts 2025

3 Marts 2025

28 Februar 2025