Dimplex DXC30Ti Manual


Læs nedenfor 📖 manual på dansk for Dimplex DXC30Ti (4 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 16 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/4
3 No. Wall
Mounting
Brackets
shelf / ceiling
floor
bracket slot
358mm centres - 2kW
478mm centres - 3kW
518mm Min.
515mm Min.
Dimensions
(millimetres)
Installation and Operating Instructions
Convector Heaters
Models : DXC20, DXC20Ti, DXC30, DXC30Ti and DXC30FTi
INDCUK35RG Issue 0
Models Specification
DXC20 2.0kw Heat Switch/Thermostat/Neon
DXC20Ti 2.0kw Heat Switch/Thermostat/24hr Timer
DXC30 3.0kw Heat Switch/Thermostat/Neon
DXC30Ti 3.0kw Heat Switch/Thermostat/24hr Timer
DXC30FTi 3.0kw Heat Switch/Thermostat/24hr Timer/Turbo Fan
IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Important Safety Advice
WARNING THIS APPLIANCE MUST NOT BE USED IN A BATHROOM.
WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL.
WARNING THIS HEATER MUST NOT BE LOCATED IMMEDIATELY
BELOW A FIXED SOCKET OUTLET.
DO NOT USE THE HEATER UNTIL THE FEET OR WALL BRACKETS
ARE FITTED CORRECTLY.
FOLLOW these instructions carefully.
NEVER cover or obstruct in any way the heat outlet slots at
the top of the heater or the air inlet slots in the base of the
heater.
The heater carries a warning ‘DO NOT COVER’ to alert the user
to the risk of fire that exists if the heater is accidentally
covered.
Timer models DXC20Ti, DXC30Ti and DXC30FTi can be set to
switch on automatically. Remember to observe all safety
warnings at all times.
Caution: In order to avoid a hazard due to inadvertent resetting
of the thermal cutout, this appliance must not be supplied
through an external switching device, such as a timer, or
connected to a circuit that is regularly switched on and off by
the utility.
This appliance is not intended for use by children or other
persons without assistance or supervision if their physical,
sensory or mental capabilities prevent them from using it
safely. Children should be supervised to ensure that they do
not play with the appliance.
If young children, the aged or infirm are likely to be left in the
vicinity of the heater, we advise that adequate precautions
should be taken. We recommend that a guard be fitted to
ensure contact with the heater is avoided and objects cannot
be inserted into the product.
If the mains lead is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid a hazard.
For further information, please contact our guard supplier
direct on Tel. No. 01603 667957, or in case of difficulty or for
further advice contact the Customer Helpline.
Electrical connection
WARNING THIS APPLIANCE MUST BE EARTHED
This heater must be used on an ~ supply only and the voltage marked on
the heater must correspond to the supply voltage. This heater is fitted
with a rewireable plug incorporating a 13 amp fuse. In the event of
replacing the fuse in the plug supplied, a 13 amp fuse approved by ASTA
to BS 1362 must be used. If any other type of plug is used, a 15 amp fuse
must be fitted in the plug, the adaptor, or at the distribution board.
IMPORTANT : If the plug is not suitable for your socket, the 13 amp plug
should be removed. Before wiring the appropriate plug, please note that
the wires in this mains lead are coloured in accordance with the following
code :
GREEN AND YELLOW: EARTH
BLUE : NEUTRAL
BROWN : LIVE
Connect the GREEN AND YELLOW wire to the terminal marked E’ or by
the earth symbol , or coloured GREEN or GREEN AND YELLOW.
Connect the BROWN wire to the terminal marked L’ or coloured RED.
Connect the BLUE wire to the terminal marked ‘N’ or coloured BLACK.
Wall Mounting
Three identical wall mounting brackets are secured to the base of the
heater with a fixing screw. To wall mount appliance, first remove the
brackets as follows :
Lay the heater on its back.
Following the sequence in Fig. 1 identify and remove the fixing screw
securing the brackets located beside Mains Cable as shown in (a), then
pull out brackets and rotate them to disengage them from the slot (b).
Withdraw the brackets from the slot (c).
Select a suitable position on a wall, near to a mains power socket, making
sure that there is
at least
230 mm below the heater and
at least
450 mm
above the heater of unobstructed space. See also Positioning the heater’.
Fix the two top retaining brackets to the wall, using suitable fixings, for
2kW models at 358mm centres and 3kW models at 478mm centres see
Fig. 2.
Locate the heater on the top brackets and allow it to hang in place.
Fit the bottom bracket into the slot in the heater and then fix it to the wall.
Test that the heater is now securely fixed to the wall.
(a) (b) (c)
Wall Mounting
Br ackets Fig. 1
Fig. 2
150
418
230 695 - 3.0kW
575 - 2.0kW
MIN
230
450
350
MIN
MIN


Produkt Specifikationer

Mærke: Dimplex
Kategori: Ikke kategoriseret
Model: DXC30Ti

Har du brug for hjælp?

Hvis du har brug for hjælp til Dimplex DXC30Ti stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Dimplex Manualer

Dimplex

Dimplex CFH90 Manual

5 Oktober 2024
Dimplex

Dimplex OCR20Tie Manual

1 Oktober 2024
Dimplex

Dimplex OPH13 Manual

29 September 2024
Dimplex

Dimplex GLN20BR Manual

18 September 2024
Dimplex

Dimplex SRX120EM Manual

17 September 2024
Dimplex

Dimplex CAB10ER Manual

12 September 2024
Dimplex

Dimplex RFM Manual

6 September 2024
Dimplex

Dimplex CAS400NH Manual

31 August 2024
Dimplex

Dimplex B48W Manual

31 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Elektron

Elektron Overbridge Manual

26 November 2024
Elektron

Elektron Sidstation Manual

26 November 2024
SoundTube

SoundTube IPD-RS82-EZ Manual

26 November 2024
Kramer

Kramer 4x1VB Manual

26 November 2024
Kramer

Kramer RC-63A Manual

26 November 2024
SoundTube

SoundTube IPD-HP82-EZ Manual

26 November 2024
Kramer

Kramer RK-KVM-1U-PP3 Manual

26 November 2024
Gioteck

Gioteck VX-2 (PS3) Manual

26 November 2024