Side 1/2
Fan Heaters
Model(s) : DXUF20T & DXUF30T
Installation and Operating Instructions
Dimensions
(millimetres)
08/35113/0 Issue 0
Electrical connection
This heater must be used on an A.C.~ supply only and the voltage
marked on the heater must correspond to the supply voltage. This heater
is fitted with a plug incorporating a 13 amp fuse. When replacing the
fuse, a 13 amp fuse approved by ASTA to BS 1362 must be used.
If the plug is not suitable for the socket outlets in your home, the plug
must be cut off and an appropriate one fitted. A plug cut off from a
mains lead will give a shock hazard if inserted into a 13 amp socket
elsewhere in the house. To avoid this, it should be disposed of
immediately.
Using the Heater
Thermostat Control - see Fig. 3
The heat output is controlled by the
thermostat, according to the room
temperature.
Turn the thermostat knob fully clockwise
to maximum setting initially. When the
room is warm enough, reduce the setting
slowly until the heater just clicks off.
The heater will now cycle on and off to maintain your selected room
temperature. An audible click may be heard when the thermostat
operates - this is normal.
Note : If the heater does not come on when the thermostat is at a low
setting, this is normally because the room is warmer than the thermostat
setting and is not a fault.
* When the heat control is set to ‘ ‘ for cool blow, set the thermostat
control to maximum.
Position *will turn the heater on and off to maintain a temperature of
approximately 5°C.
- OFF
- Cool Blow*
- Half heat
- Full heat
Heat Control - see Fig. 2
(IP20)
H W D
236 242 175
Model(s) Specification
DXUF20T 2.0kW Thermostat & Switch
DXUF30T 3.0kW Thermostat & Switch
Fig. 2
Fig. 3
(see Fig. 3)
Fig. 1
(see Fig. 2)
IMPORTANT SAFETY ADVICE
READ THESE INSTRUCTIONS BEFORE USE.
DO NOT use the heater on deep pile carpets or the long hair
type of rugs, or less than 750mm (30") away from any
overhanging surface. Keep combustible materials such as
drapes and other furnishings clear from the front, sides
and rear of the heater. Do not use heater to dry your laundry.
DO NOT use the heater in the immediate surroundings of a
bath, a shower or a swimming pool.
DO NOT place the heater directly below a fixed socket outlet.
The socket-outlet must be accessible at all times to enable
the mains plug to be disconnected as quickly as possible.
DO NOT COVER or obstruct the air inlet and outlet openings
in any way.
The heater must be on a flat stable surface when in use.
DO NOT operate the heater with the mains lead overhanging
the front outlet grille.
NEVER leave the heater unattended when it is used by or
near the aged, infirm persons or children.
The heater carries the Warning symbol indicating that
it must not be covered.
The instruction leaflet belongs to the appliance and must
be kept in a safe place. If changing owners, the leaflet
must be surrendered to the new owner.
IMPORTANT If the mains lead of this appliance is damaged,
it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a
hazard.
WARNING: In order to avoid a hazard due to inadvertent
resetting of the thermal cut-out, this appliance must not be
supplied through an external switching device, such as a
timer, or connected to a circuit that is regularly switched on
and off by the utility.
IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
NOTE: The fuse cover of a non-rewirable plug must be refitted when
changing the fuse. Should the cover become lost, the plug must not be
used until the correct replacement fuse cover is obtained from your
supplier or by contacting our customer helpline.
IMPORTANT : The wires in this mains lead are coloured in accordance
with the following code :
BLUE : NEUTRAL
BROWN : LIVE
As the colours of the wires in the mains lead may not correspond with
the coloured markings in your plug, proceed as follows :
Connect the BROWN wire to the terminal marked L or coloured RED.
Connect the BLUE wire to the terminal marked ‘N or coloured BLACK.
Note :L orN must not be connected to the EARTH terminal marked
‘ .Eor or coloured GREEN or GREEN AND YELLOW
If in doubt, consult your electrician.
*


Produkt Specifikationer

Mærke: Dimplex
Kategori: Varmeapparat
Model: DXUF30T

Har du brug for hjælp?

Hvis du har brug for hjælp til Dimplex DXUF30T stil et spørgsmål nedenfor, og andre brugere vil svare dig




Varmeapparat Dimplex Manualer

Dimplex

Dimplex MPH500 Manual

8 Oktober 2024
Dimplex

Dimplex ECOT4FT Manual

8 Oktober 2024
Dimplex

Dimplex FUTM2CE Manual

4 Oktober 2024
Dimplex

Dimplex VFM60HY Manual

4 Oktober 2024
Dimplex

Dimplex VFD20 Manual

2 Oktober 2024
Dimplex

Dimplex OFC2500TLG Manual

20 September 2024
Dimplex

Dimplex DI5110225 Manual

15 September 2024
Dimplex

Dimplex GFP200W Manual

14 September 2024
Dimplex

Dimplex VF8017E Manual

12 September 2024
Dimplex

Dimplex PLX200E Manual

11 September 2024

Varmeapparat Manualer

Nyeste Varmeapparat Manualer

Heinner

Heinner HOH-M11WH-BK Manual

11 December 2024
Ravanson

Ravanson LKK-50B Manual

9 December 2024
Ravanson

Ravanson LKK-120ERB Manual

9 December 2024
Harvia

Harvia QUBE-360 Manual

8 December 2024
Harvia

Harvia Forte AFB4 Manual

8 December 2024
Vornado

Vornado VMHi500 Manual

7 December 2024
Ravanson

Ravanson LKK-120ERC Manual

7 December 2024
Brandson

Brandson 306997 Manual

7 December 2024
Domo

Domo DO9282WK Manual

6 December 2024