Installation and Operating Instructions
INDGUKP7RG Issue 0
Girona Panel Heaters
Dimensions
(millimetres)
Model(s) Watt A B
GFP050 W/B 0.5kW 530 107
GFP075 W/B 0.75kW 530 107
GFP100 W/B 1.0kW 700 107
GFP150 W/B 1.5kW 770 107
GFP200 W/B 2.0kW 940 107
Important Safety Advice
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electrical shock, and injury to persons, including the
following:
IIMPORTANT The wall bracket supplied with the
appliance must be used.
WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING
POOL.
IMPORTANT If the heater is installed in a room
containing a bath or shower, it must be so installed that
switches and other controls cannot be touched by a
person using a bath or shower.
Do not use outdoors.
Do not locate the heater immediately below a fixed socket
outlet or connection box.
Do not cover the heater. Do not place material or
garments on the heater, or obstruct the air circulation
around the heater, for instance by curtains or furniture,
as this could cause overheating and a fire risk.
NEVER cover or obstruct in any way the heat outlet slots
at the top of the heater or the air inlet slots in the base of
the heater.
The heater carries the Warning symbol indicating
that it must not be covered.
WARNING THE SURFACES OF THIS HEATER CAN BE HOT.
Momentary contact with any part of the heater should
not cause injury.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person
responsible for their safety. Children should be
supervised to ensure that they do not play with the
appliance.
Note that due care and consideration must be taken
when using this heater in series with a thermal control,
a program controller, a timer or any other device that
switches on the heat automatically, since a fire risk
exists when the heater is accidentally covered or
displaced.
If the supply cord is damaged it must be replaced by the
manufacturer or service agent or a similarly qualified
person in order to avoid a hazard.
Fig. 1
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Electrical
WARNING THIS APPLIANCE MUST BE EARTHED
The electrical installation must be carried out by a competent
electrician, and be in strict accordance with the current I.E.E.
regulations for Electrical Equipment in Buildings.
The wires in this mains lead are coloured in accordance
with the following code :
GREEN AND YELLOW : EARTH
BLUE : NEUTRAL
BROWN : LIVE
BLACK : PILOT WIRE
- see also ‘Pilot Wire Connection’.
The heater is fitted with a length of flexible cable type H05VV-
F size 4 x 1.0mm2 for connection to the fixed wiring of the
premises through a suitable connection box positioned
adjacent to the heater.
The supply circuit to the heater must incorporate a double
pole isolating switch having a contact separation of at least
3mm.
Pilot Wire Connection
The BLACK control wire is designed to carry a signal from
slot in or wall mounted Dimplex programmers. If, however a
programmer is not being used, the pilot wire should be
isolated in accordance with the current IEE Wiring
Regulations.
IMPORTANT - DO NOT connect the BLACK pilot wire to earth.
Care should be taken with the installation of the pilot wire(s)
as when switching to background (set back) they become
energised at 240V although only at a current of less than
100mA. In every case a suitable means of isolation must be
provided for the pilot wire and marked to indicate that two
sources of supply may be present at the heater.
Where pilot wires are installed separately from the heater
final sub-circuit they should be protected, double insulated
and carry their own integral earth continuity conductor.
Supplementary Earth Bonding
Should Equipotential Earth Bonding be required the earthing
conductor in the supply cord is deemed to provide the
supplementary bonding connection (see Regulation 547-
03-05, 16th Edition I.E.E. Wiring Regulations).
A
565
B150
Min.
300 Min.
shelf
150 Min.


Produkt Specifikationer

Mærke: Dimplex
Kategori: Varmeapparat
Model: GFP200W

Har du brug for hjælp?

Hvis du har brug for hjælp til Dimplex GFP200W stil et spørgsmål nedenfor, og andre brugere vil svare dig




Varmeapparat Dimplex Manualer

Dimplex

Dimplex MPH500 Manual

8 Oktober 2024
Dimplex

Dimplex ECOT4FT Manual

8 Oktober 2024
Dimplex

Dimplex FUTM2CE Manual

4 Oktober 2024
Dimplex

Dimplex VFM60HY Manual

4 Oktober 2024
Dimplex

Dimplex VFD20 Manual

2 Oktober 2024
Dimplex

Dimplex OFC2500TLG Manual

20 September 2024
Dimplex

Dimplex DI5110225 Manual

15 September 2024
Dimplex

Dimplex GFP200W Manual

14 September 2024
Dimplex

Dimplex VF8017E Manual

12 September 2024
Dimplex

Dimplex PLX200E Manual

11 September 2024

Varmeapparat Manualer

Nyeste Varmeapparat Manualer

Heinner

Heinner HOH-M11WH-BK Manual

11 December 2024
Ravanson

Ravanson LKK-50B Manual

9 December 2024
Ravanson

Ravanson LKK-120ERB Manual

9 December 2024
Harvia

Harvia QUBE-360 Manual

8 December 2024
Harvia

Harvia Forte AFB4 Manual

8 December 2024
Vornado

Vornado VMHi500 Manual

7 December 2024
Ravanson

Ravanson LKK-120ERC Manual

7 December 2024
Brandson

Brandson 306997 Manual

7 December 2024