Dimplex S50C Manual


Læs nedenfor 📖 manual på dansk for Dimplex S50C (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 6 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Dimensions
(millimetres)
Installation and Operating Instructions
Electric Towel Rails
Models : S50W & S50C
08/17199/9 (UK) Issue 9
Fig. 1
Important Safety Advice
WARNING - THE SURFACE OF THIS RADIATOR CAN BE HOT.
In order to be effective the towel rail will get hot, however
momentary contact with any part of it should not cause injury.
WARNING - In order to avoid a hazard for very young children,
this appliance should be installed so that the lowest heated rail is
at least 600mm above the floor.
WARNING - This appliance must not be located immediately above
or below a fixed socket outlet or connection box.
IMPORTANT - If the towel rail is to be installed in a place used by
the public, a warning notice should be placed adjacent to the rail
advising that the surface can be hot.
CAUTION - This appliance is not intended for use by chidren or
other persons without assistance or supervision if their physical,
sensory or mental capabilities prevent them from using it safely.
Children should be supervised to ensure that they do not play
with the appliance.
The towel rail is to be installed so that switches and other controls
cannot be touched by a person in the bath or shower.
IMPORTANT - If the supply cord is damaged it must be replaced
by the manufacturer or service agent or a similarly qualified person
in order to avoid a hazard.
Precautions should be taken to ensure that prolonged contact
with the towel rail cannot occur. Particular care should be taken
in confined areas where accidental prolonged contact with the
rail could be more likely to occur.
This appliance should only be used to dry fabrics washed in
water using commonly available detergents.
General
Your Dimplex electric towel rail has been designed to provide an all-
the-year-round service for airing towels and articles of clothing. It is
not intended to provide a sole heating service.
The Dimplex S50W & S50C Towel Rails are designed for wall mounting
only, and are splash-proof.
The Dimplex Towel Rails have a loading of 45W and will therefore
operate for 22 hours on one unit of electricity (lkWh).
Use
Your Dimplex electric towel rail can quite safely be left on continuously
if desired without detrimental effect. When in use however no more
than three layers of towelling or similar fabric should be draped over
each rail. It is not advisable to leave very damp clothes or towels on
the rail when it is not in use, as this may affect the finish.
The rail when in use, though hot to the touch, is not hot enough to
scorch or burn towels or clothes. However, soap and
detergents remaining in articles after washing can cause what appear
to be scorch marks after being in contact with a hot rail. Care should
be taken therefore to thoroughly rinse out all articles before airing.
Electrical
The electrical installation of this towel rail must be carried out by a
competent electrician in accordance with the current I.E.E Regulations
for Electrical Equipment. The towel rail is suitable for use on an A.C.~
electrical supply. Before installation check that the supply voltage
corresponds with that marked on the rail.
WARNING - THIS APPLIANCE MUST BE EARTHED.
IMPORTANT - The wires in the mains lead are coloured in
accordance with the following code:
GREEN and YELLOW - EARTH
BLUE - NEUTRAL
BROWN - LIVE
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured markings identifying
the terminals in your plug, proceed as follows:
The wire which is coloured GREEN and YELLOW must be
connected to the terminal in the plug which is marked with the letter
E or by the earth symbol or coloured green or green and yellow.
The wire which is coloured BLUE must be connected to the terminal
which is marked with the letter N or coloured black.
The wire which is coloured BROWN must be connected to the terminal
which is marked with the letter L or coloured red.
This appliance must only be used on A.C. mains supply of 230/240
Volts~.
In accordance with wiring rules a suitable means for
disconnection must be incorporated in the fixed wiring.
If fitted in a room containing a bath or shower, to comply with the
current I.E.E. Regulations, a cable outlet will be necessary with the
supply to the heater controlled by a double-pole pull-cord switch
having a contact separation of 3mm in each pole. The body of the
switch should be situated as to be normally inaccessible to a person
using a bath or shower.
IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
50 min.
11
5
550
170
290
555
(x)


Produkt Specifikationer

Mærke: Dimplex
Kategori: Ikke kategoriseret
Model: S50C

Har du brug for hjælp?

Hvis du har brug for hjælp til Dimplex S50C stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Dimplex Manualer

Dimplex

Dimplex CFH90 Manual

5 Oktober 2024
Dimplex

Dimplex OCR20Tie Manual

1 Oktober 2024
Dimplex

Dimplex OPH13 Manual

29 September 2024
Dimplex

Dimplex GLN20BR Manual

18 September 2024
Dimplex

Dimplex SRX120EM Manual

17 September 2024
Dimplex

Dimplex CAB10ER Manual

12 September 2024
Dimplex

Dimplex RFM Manual

6 September 2024
Dimplex

Dimplex CAS400NH Manual

31 August 2024
Dimplex

Dimplex B48W Manual

31 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Gigabyte

Gigabyte ODIN GT 550W Manual

23 November 2024
Stamos

Stamos S-PLASMA 60U Manual

23 November 2024
Velbus

Velbus VMBPIRO-W-20 Manual

23 November 2024
Honor

Honor 90 Pro Manual

23 November 2024
Honor

Honor 80 SE Manual

23 November 2024
Medela

Medela Safe & Dry Manual

22 November 2024
Jane

Jane First Potty Manual

22 November 2024