Lock Modes
A lock is shipped from the factory with default lock “setup” values and a pre-set PIN
for unlocking the lock. This is referred to as Factory Mode.
The lock is shipped with a default factory Super Master User PIN that can be set
(i.e., changed) when the lock is in Factory Mode. Once the Super Master User PIN is
set, the Super Master User combination can be used to shelve the lock in the event
that the Master User combination is lost.
WARNING:
The setting of the Super Master User PIN is optional, however, if you do
not set the Super Master User PIN before setting the Master User PIN, all
Super Master User capabilities will be permanently lost.
The lock is removed from Factory Mode when the Master User PIN gets changed,
The lock has two modes of operation: Independent Mode and Supervisory/
Subordinate Mode. Within each operation mode, two access modes are available:
Single User access Dual User access and . In Single User access, only one
combination is required to open the lock. In Dual User access, two combinations
must be correctly and consecutively entered to open the lock.
Independent Mode - To operate in Independent Mode, the Master User must
first add Access Users. One (Single User access) or two (Dual User access)
combinations are required to open the lock.
Supervisory/Subordinate Mode (Super/Sub Mode) - To operate in Super/Sub
Mode, the Master User must first add a Supervisor. Subordinate Users must
then be added by and assigned to a Supervisor. A Supervisor must enable
lock access for Subordinate User(s).
In Single User access, an enabled Subordinate User combination is required to
open the lock.
In Dual User access, two enabled Subordinate User combinations are required
to open the lock.
Once a Supervisor combination and the Supervisor ID are re-entered to disable
lock access for the Subordinate User(s) assigned to that Supervisor ID, the
Subordinate User combinations for that will no longer open the lock.
To remove a lock from an operational mode, one can “shelve” the lock which places
it in Shelved Mode. Most lock values are returned to the factory default.
AUDITCON® 2 SERIES
MODELS 252 & 552
OPERATING INSTRUCTIONS
Document Number 3036.074 Rev. C - 12/06


Produkt Specifikationer

Mærke: Dormakaba
Kategori: Ikke kategoriseret
Model: Auditcon 252

Har du brug for hjælp?

Hvis du har brug for hjælp til Dormakaba Auditcon 252 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Dormakaba Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Elektron

Elektron Overbridge Manual

26 November 2024
Elektron

Elektron Sidstation Manual

26 November 2024
SoundTube

SoundTube IPD-RS82-EZ Manual

26 November 2024
Kramer

Kramer 4x1VB Manual

26 November 2024
Kramer

Kramer RC-63A Manual

26 November 2024
SoundTube

SoundTube IPD-HP82-EZ Manual

26 November 2024
Kramer

Kramer RK-KVM-1U-PP3 Manual

26 November 2024
Gioteck

Gioteck VX-2 (PS3) Manual

26 November 2024