Dormakaba RCI 8310 Manual


Læs nedenfor 📖 manual på dansk for Dormakaba RCI 8310 (6 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 8 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/6
INSTALLATION
RCI 8310 / 8320
ELECTROMAGNETIC LOCKS
© 2020 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
IS8310-20-V1-2
PCN19025
R07-20GR-1
1. Mount the electromagnetic lock to the door frame as outlined on
the installation template included with the product.
NOTE: During installation of the armature plate to the door it
is essential that the armature plate remains movable. The
armature plate must be allowed to pivot on the center-mounting
bolt to allow proper alignment with the magnet surface. If the
plate is not aligned with the magnet surface, the lock may lose
holding force or not lock at all .
The head of the armature mounting bolt ships with a rubber
washer affixed to it. This washer should project slightly beyond
the surface of the armature plate. This is to allow the washer to
expand when power is removed and break the air vacuum
between the plate and the magnet surface. If this washer is
removed or trimmed the lock will appear to have some holding
force even when power is removed.
For added safety, thread locking compound has been provided for
the armature plate bolt and the four captive electromagnetic lock
mounting screws.
WARNING: Improper installation, maintenance, inspection or usage
of the product or any related accessories or parts may cause the
electromagnetic lock, armature plate and associated hardware
to disengage and fall, causing serious bodily injury and property
damage. dormakaba Canada Inc. and/or dormakaba USA Inc. will
not be liable to the installer, purchaser, end user or anyone else for
damage or injury to person or property due to improper installation,
care, storage, handling, maintenance, inspection, abuse, misuse
or act of God or nature involving this product or any related
accessories or parts.
2. Route the power supply connecting wire through the door frame
and into the wire access hole in the top of the magnet housing.
Connecting wire should be of sufficient gauge for the lock being
installed and the distance being run.
Installation Instructions
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO
THE END-USER UPON COMPLETION OF THE INSTALLATION.
Pre-Installation Instructions
1. This product must be installed according to all applicable building
and life safety codes.
2. Due to the variety of mounting configurations available with this
product, a survey and assessment of the physical area in which
the product will be installed must be performed.
3. The door frame must be inspected and deemed structurally sound
prior to installation of the electromagnetic lock. The structural
integrity of the mounting surfaces must be strong enough to meet
or exceed the holding force of the product.
4. The product must be protected from potential damage due to
intruders or tampering.
5. The product should be installed in a location that will not hinder
or create a potential safety hazard to authorized personnel
accessing the protected area.
6. Because electromagnetic locks are used in a variety of applications
and different door frame configurations, an experienced installer
with knowledge of this product must make a determination of the
optimal mounting method for this specific application.
7. The components, hardware, installation instructions and mounting
template included with this product are intended for use on
outswinging doors.
8. Do not install this product on the exterior of buildings.
9. Do not use as a doorstop. This will void warranty.
10. Separate accessories, must be used in the following applications:
Inswinging doors
Narrow head jamb situations or center-hung doors
Wherever there is insufficient space on the door
frame header to mount the lock
Glass or Herculite doors that do not have a door frame
Hollow metal or wood frames where the door stop is
not thick enough to allow the product to be installed
Wherever an obstruction in the door prevents
installation of the armature plate at a proper height
Doors that do not permit the armature plate to be
mounted low enough to meet the magnet surface
Refer to the page 5 & 6 Product Accessories Guide, for further
information. Accessories may impact holding force.
11. Installation of this product should be done by an experienced
installer with knowledge of this product.
NOTE: It is highly recommended that thread locking compound
be applied to all screws during installation to reduce chance of
screws loosening over extended time.


Produkt Specifikationer

Mærke: Dormakaba
Kategori: Ikke kategoriseret
Model: RCI 8310

Har du brug for hjælp?

Hvis du har brug for hjælp til Dormakaba RCI 8310 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Dormakaba Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Elektron

Elektron Overbridge Manual

26 November 2024
Elektron

Elektron Sidstation Manual

26 November 2024
SoundTube

SoundTube IPD-RS82-EZ Manual

26 November 2024
Kramer

Kramer 4x1VB Manual

26 November 2024
Kramer

Kramer RC-63A Manual

26 November 2024
SoundTube

SoundTube IPD-HP82-EZ Manual

26 November 2024
Kramer

Kramer RK-KVM-1U-PP3 Manual

26 November 2024
Gioteck

Gioteck VX-2 (PS3) Manual

26 November 2024