INSTALLATION
RCI 8375
SURFACE MICROMAG® ELECTROMAGNETIC LOCKS
© 2020 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.com
IS8375
PCN18041
R03-20GR-1
Pre-Installation Instructions
1. This product must be installed according to all applicable building
and life safety codes.
2. Due to the variety of mounting configurations available with this
product, a survey and assessment of the physical area in which
the product will be installed must be performed.
3. The door frame must be inspected and deemed structurally sound
prior to installation of the electromagnetic lock. The structural
integrity of the mounting surfaces must be strong enough to meet
or exceed the holding force of the product.
4. The product must be protected from potential damage due to
intruders or tampering.
5. The product should be installed in a location that will not hinder
or create a potential safety hazard to authorized personnel
accessing the protected area.
6. Because electromagnetic locks are used in a variety of applications
and different door frame configurations, an experienced installer
with knowledge of this product must make a determination of the
optimal mounting method for this specific application.
7. The components, hardware, installation instructions and mounting
template included with this product are intended for use on
outswinging doors.
8. Do not install this product on the exterior of buildings.
9. Do not use as a doorstop. This will void warranty.
10. Separate accessories not included with this product must be used
in the following applications:
Inswinging doors
Narrow head jamb situations or center-hung doors
Wherever there is insufficient space on the door
frame header to mount the lock
Glass or Herculite doors that do not have a door frame
Hollow metal or wood frames where the door stop is
not thick enough to allow the product to be installed
Wherever an obstruction in the door prevents
installation of the armature plate at a proper height
Doors that do not permit the armature plate to be
mounted low enough to meet the magnet surface
Refer to the page 4 Product Accessories Guide for further
information. Accessories may impact holding force.
11. Installation of this product should be done by an experienced
installer with knowledge of this product.
NOTE: It is highly recommended that thread locking compound be
applied to all screws during installation to reduce chance of screws
loosening over extended time.
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO
THE END-USER UPON COMPLETION OF THE INSTALLATION.
Fig. 1.
8375 Mounting
Plate Removal
Fig. 2 8375 Voltage Selection Jumper Setting
12VDC Operation 24VDC Operation
(Factory Setting)
Electromagnetic lock installations must conform to local fire codes, National
building codes and Life Safety Codes.
Mounting
Bracket
Releases captive
mounting screws


Produkt Specifikationer

Mærke: Dormakaba
Kategori: Ikke kategoriseret
Model: RCI 8375

Har du brug for hjælp?

Hvis du har brug for hjælp til Dormakaba RCI 8375 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Dormakaba Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer