DIN-AP3
DIN Rail 3-Series® Automation Processor
Installation and Operations Guide
Hardware Hookup
Make the necessary connections, and apply power after all connections have been made.
NOTE: When making connections to the DIN-AP3, observe the following points:
Use Crestron power supplies for Crestron equipment.
The included cable cannot be extended.
Hardware Connections for the DIN-AP3 (Front View)
Description
The Crestron® DIN-AP3 is a 3-Series Control System® automation processor designed for
DIN rail mounting. Featuring the 3-Series control engine, the DIN-AP3 forms the core of
any modern networked home or commercial building, managing and integrating all the
disparate technologies throughout the facility.
Installation
CAUTION: The DIN-AP3 is for indoor use only. Mount in a well-ventilated area. The
ambient temperature must be 32ºF to 104ºF (0ºC to 40ºC). The relative humidity must be
10% to 90% (noncondensing).
CAUTION: To prevent overheating, do not operate this product in an area that exceeds
the environmental temperature range listed on the product web page. Consider using
forced air ventilation to reduce overheating. Also use consideration if installing in a
closed or multiunit rack assembly, since the operating ambient temperature of the
environment may be greater than the room ambient temperature. Contact with thermal
insulating materials should be avoided on all sides of the unit.
NOTES: Observe the following points:
When installing the DIN-AP3 in an enclosure, group high-voltage devices separately
from low-voltage devices.
Install and use the DIN-AP3 in accordance with appropriate electrical codes and
regulations.
A licensed electrician must install the DIN-AP3.
NOTE: Before using the DIN-AP3, ensure the device is using the latest rmware. Check
for the latest rmware for the DIN-AP3 at www.crestron.com/rmware. Firmware is
loaded onto the device using Crestron Toolbox™ software.
Preparing and Connecting Wires
When making the connections, strip the ends of the wires approximately 7/16 in (11 mm).
Use care to avoid nicking the conductors. Tighten the connector to 5 in-lb
(0.5 to 0.6 N-m). The wire gauge should be 14 to 26 AWG.
Installing the DIN-AP3
The DIN-AP3 should be used in a well-ventilated area. The venting holes should not be
obstructed under any circumstances.
The DIN-AP3 is designed for installation on a DIN rail. Refer to the diagram when installing.
Installing the DIN-AP3
Additional Resources
Visit the product page on the Crestron website (www.crestron.com)
for additional information and the latest rmware updates. Use a QR
reader application on your mobile device to scan the QR image.
I/O (G, 8—1):
To Controllable Devices
From Device Outputs (Contact
Closure or Relay Closure)
RELAY (1—4):
To Controllable
Devices
IR/SERIAL (1—4):
To IRP2 or Serial
Devices
COMPUTER:
To Computer Console
COM (1—2):
To RS-232/422/485
Devices
NET (24 Y Z G):
To Any Cresnet® Network Device
Hardware Connections for the DIN-AP3 (Bottom View)
LAN:
10Base-T/100Base-Tx
Ethernet to LAN
Hardware Connections for the DIN-AP3 (Top View)
Memory:
For SD Card
NOTE: Ensure the unit is properly grounded by connecting the chassis ground lug to an
earth ground (building steel).
NOTE: To prevent overheating, do not operate this product in an area that exceeds the
environmental temperature range stated earlier.
Install the DIN-AP3:
1. Use a at object (e.g., a at-head screwdriver) to pull the DIN rail release downward.
2. Place the top of the DIN-AP3’s rail mount over the top of the DIN rail.
3. Tilt the bottom of the DIN-AP3 toward the DIN rail until it snaps into place
NOTE: When mounting DIN rail products, it may be necessary to use a at-head
screwdriver to pull the DIN rail release tab while snapping the device onto the DIN
rail.
To remove the DIN-AP3 from the DIN rail, use a small, at object (e.g., a at-head
screwdriver) to pull the DIN rail release, and tilt the bottom of the DIN-AP3 away from the
DIN rail.
NOTE: Certain third-party DIN cabinets provide space for an informational label between
each DIN rail row. Crestron’s Engraver software (version 4.0 or later) can generate
appropriate labels for all Crestron DIN rail products.
Congure the Control System
The control system can be congured using Crestron Toolbox or the built-in, web-based
setup tool.
Crestron Toolbox
Use Crestron Toolbox to establish communication and congure the control system. For
details, refer to the Crestron Toolbox help le.
Web-Based Setup Tool
1. Use Crestron Toolbox to set the time zone. For details, refer to the Crestron Toolbox
help le.
2. Use the Internet Explorer® web browser to navigate to http://xxx.xx.xx.xxx/setup
where xxx.xx.xx.xxx is the IP address of the control system. The control system’s
welcome screen is displayed.
NOTE: The web-based setup tool is accessible only from Internet Explorer.
NOTE: If a security warning is displayed, click Install to continue.
3. Click Setup to display the DIN-AP3 setup menu. The DIN-AP3 setup menu displays
the IP address, hostname, and MAC address of the device. It also allows access to
various setup and programming screens.
4. From the DIN-AP3’s setup menu, click the following options to congure the control
system:
Ethernet Setup congures the DIN-AP3’s Ethernet settings and displays DHCP,
hostname, IP address, subnet mask, default router, domain, and MAC address
settings. In the Ethernet setup menu, there are additional options:
Click Advanced Settings to specify DNS servers, web server settings, and
SSL settings.
Click MyCrestron Dynamic DNS to congure the myCrestron.com Dynamic
DNS service.
Click Ethernet Diagnostics to test the Ethernet communications.
Click Reboot to reboot the DIN-AP3.
selects programs to be loaded on startup and controls which Application Setup
program(s) are running.
congures the COM ports, operates the relays, and Input/Output Control
monitors the Versiports.
displays information about the connected devices, hardware Diagnostics
conguration, and error logs.
About displays rmware information.
Click to return to the previous screen.


Produkt Specifikationer

Mærke: Einhell
Kategori: savemaskine
Model: TE-TS 2231 U

Har du brug for hjælp?

Hvis du har brug for hjælp til Einhell TE-TS 2231 U stil et spørgsmål nedenfor, og andre brugere vil svare dig




savemaskine Einhell Manualer

Einhell

Einhell GE-CS 18 Li Manual

15 Oktober 2024
Einhell

Einhell TC-AP 650 E Manual

12 Oktober 2024
Einhell

Einhell BT-SM 2534 Manual

11 Oktober 2024
Einhell

Einhell RT-TS 1725/1 U Manual

30 September 2024
Einhell

Einhell ST 315 Manual

30 September 2024
Einhell

Einhell E-Stand Manual

12 September 2024
Einhell

Einhell LMP 440 Manual

6 September 2024
Einhell

Einhell RT-FF 1220 U Manual

6 September 2024

savemaskine Manualer

Nyeste savemaskine Manualer

MSW

MSW -TAS287 Manual

15 Oktober 2024
MSW

MSW T-SAW300 Manual

15 Oktober 2024
Makita

Makita 5603 Manual

14 Oktober 2024
FERM

FERM FKS-165 Manual

13 Oktober 2024
Hitachi

Hitachi C 7MFA(LA) Manual

9 Oktober 2024
Ozito

Ozito ECS-406A Manual

6 Oktober 2024
Ferrex

Ferrex DX254TS Manual

5 Oktober 2024
Scheppach

Scheppach Deco-Fex Manual

3 Oktober 2024