ER500
Espansione radio
Radio expansion
Extension radio
2
ELKRON
TEL. +39.011.3986711
FAX +39.011.3986703
www.elkron.com – mail to: info@elkron.it
ELKRON
è un marchio commerciale di
URMET S.p.A.
ELKRON is a trademark of URMET S.p.A.
ELKRON est une marque commercial d’URMET S.p.A
.
Via Bologna, 188/C - 10154 Torino (TO) – Italy
www.urmet.com
ITALIANO
DESCRIZIONE GENERALE
L’espansione radio ER500 è in grado di gestire una comunicazione radio bidirezionale
a 868,35 MHz, con i dispositivi radio ad essa associati. Attraverso un BUS a 4 fili, può
essere connessa direttamente alla centrale filare Elkron, permettendo a questa una
gestione mista di dispositivi filari e radio.
Il numero di dispositivi radio gestibili da una singola espansione ER500 è:
Tipo dispositivo Numero massimo
Sensori (infrarossi IR500; Contatti DC500) 16
Sirene HP500; IS500 2
Telecomandi RC500 4
ATTENZIONE:
In questo documento sono riportate solo alcune indicazioni essenziali
relative al prodotto. Per ulteriori e dettagliate informazioni fare riferimento ai manuali della
centrale Elkron in grado di gestire l’espansione ER500.
1
MONTAGGIO
L’espansione radio ER500, può essere montata, o all’interno della centrale (fare
riferimento al manuale di Installazione della centrale), o all’interno del contenitore CP/EXP
cod. MP4J00111 in posizione Size 1 (riferirsi al foglio istruzioni del contenitore).
All’interno della centrale può essere montata una sola espansione radio ER500.
Trattandosi di un dispositivo radio trasmittente/ricevente, l’espansione deve essere
installata con tutte le precauzione tipiche delle installazioni di questo tipo.
In caso di utilizzo del contenitore CP/EXP, questo va posizionato
:
in un luogo interno non di passaggio
,
in un luogo non soggetto a sbalzi eccessivi di temperatura
,
in un luogo protetto dall’impianto antintrusione
lontano da campi elettromagnetici
.
2
MORSETTI, PULSANTI E LED
Descrizione
+ Alimentazione espansione via BUS
+D
D Trasmissione dati via BUS
Alimentazione espansione via BUS
A
Tamper Collegamento del microswitch protezione contenitore CP/EXP
Pulsante
B LED giallo Pulsante e Led per l’acquisizione dell'espansione
LED verde
Segnalazione funzionamento (per dettagli vedere Manuale di
Programmazione)
Lampeggiante lento = condizioni di normale funzionamento
Lampeggiante veloce = segnalazione di mancato colloquio con
la centrale da almeno 1 minuto
C
Jumper Ponticello per l’esclusione del Tamper
(ponticello inserito = tamper escluso)
D LED verde Segnalazione funzionamento modulo radio
3
COLLEGAMENTO BUS E TAMPER
L’espansione può essere collegata sul bus in cascata, a stella o in modo misto.
La posizione dell’espansione lungo il bus non ha particolare importanza.
Collegare l’espansione al bus, utilizzando i morsetti “+”; “+D”; “D”; “”.
Per il cablaggio usare un cavo schermato a 4 conduttori (2 per l’alimentazione e 2 per il
collegamento dati). Nel conteggio generale dell’assorbimento dell’impianto considerare il
consumo max dell’espansione.
Per l’installazione nel contenitore CP/EXP, collegare il Tamper della scatola, all’ingresso
Tamper dell’espansione.
4
ACQUISIZIONE ESPANSIONE
Acquisire l’espansione premendo l’apposito pulsante
B
”.
Per ulteriori informazioni su procedimento di acquisizione fare riferimento al manuale
d’installazione della centrale
.
5
CARATTERISTICHE TECNICHE
Tensione nominale di alimentazione: 13.8 Vcc (prelevati tramite bus)
Tensione di funzionamento: 9 Vcc ÷ 15 Vcc
Corrente nominale assorbita a 12 Vcc : 35 mA
Assorbimento max. corrente picco: 45 mA
Lunghezza max. complessiva della linea
seriale Bus Centrale - espansione radio: 400 m
Tecnologia di comunicazione: Radio frequenza bi-direzionale.
Modalità di comunicazione radio: FSK
Frequenza: 868,35 MHz
Numero canali radio: 1
Portata radio: > 100 m in aria libera
Temperatura di funzionamento dichiarata: -5 °C ÷ +40 °C
Umidità relativa di funzionamento: 95 % a +40 °C
Protezione antiapertura contenitore: Tamper antimanomissione
ENGLISH
GENERAL DESCRIPTION
ER500 radio expansion is able to perform a bidirectional 868,35MHz radio communication,
with the associated radio devices.
By means of a 4 wires bus it could be connected to the Elkron wired control panel, allowing
a mixed management of wired and wireless devices.
Each ER500 radio expansion could manage up to:
Device type Maximum number
Detectors (IR500 infrared ; DC500 Door Contact) 16
HP500 and IS500 Sirens 2
RC500 Remote Control 4
CAUTION:
in this document there are only present some essential indications about
product.
For further and detailed information refer to the Elkron control panel manuals able to
handle the ER500 expansion.
1
MOUNTING
ER500 radio expansion could be mounted inside the control panel box (refer to the
installation manual), or inside a wall box type CP/EXP cod. MP4J00111 in position Size 1
(refer to the wall box instruction sheet).
Inside the MP508TG box could be only mounted one ER500 radio extension.
Since ER500 is a radio device, this extension should be installed carefully, taking into
account all the precautions typical of such installations.
In case of using the CP/EXP wall box, this must be positioned:
in an inner location which is neither a transition location
,
in a location subjected to excessive sudden rises/falls in temperature
,
in a location is protected by anti-burglar system
far from electromagnetic fields
.
2 TERMINAL BLOCK, BUTTONS AND LED
Description
+ Expansion power supply via bus.
+D
D Data transmission via bus
Expansion power supply via bus
A
Tamper Connection for the CP/EXP protection microswitch
Button
B Yellow LED Button and LED for expansion capture
Green LED
Working condition (for details see Programming manual)
Slow Blinking = normal running
Fast Blinking = indicates the loss of communication with the
control panel for at least 1 minute
C
Jumper Jumper for Tamper exclusion
(inserted = Tamper excluded)
D Green LED Radio module working condition
3
BUS AND TAMPER CONNECTION
Expansion can be connected on bus in a cascade, star or mixed way.
Expansion position along bus is not important
.
Connect expansion to bus using terminals block “+”; “+D”; “D”; “”.
For wiring, use 4 lead screened cable (2 leads for power supply and 2 leads for data
connection). In counting out overall system absorption, also consider max consumption of
the expansion.
If installed in the wall box CP/EXP, connect the box Tamper to the Tamper input of the
expansion.
4
EXPANSION CAPTURE
Capture expansion by pressing specialB” button.
For further information about acquire procedure, refer to installation manual of the control
panel.
5
TECHNICAL CHARACTERISTICS
Supply nominal voltage: 13.8 Vdc (taken with the bus)
Working voltage: 9 Vdc ÷ 15 Vdc
Nominal current consumption at 12 Vdc : 35 mA
Maximum current consumption (peak): 45 mA
Control panel-radio expansion serial line bus
max. length: 400 m
Communication technology: Bidirectional radio frequency
Radio communication mode: FSK
Frequency: 868,35 MHz
Number of radio channels: 1
Radio range: > 100 m in free air
Declared operation temperature: -5 °C ÷ +40 °C
Working relative humidity: 95 % a +40 °C
Case anti-opening protection: Anti-tamper device
FRANÇAIS
DESCRIPTION GÉNÉRALE
L’extension radio ER500 permet de gérer une communication radio bidirectionnelle à
868,35MHz avec les dispositifs radio associées. L’extension peut être branchée sur la
centrale filaire Elkron par moyen du bus a quatre conducteurs, permettent une gestion
mixte de dispositifs filaires et radio.
Le numéro maximal des dispositifs radio gérées par une extension ER500 est:
Type dispositif Nombre maximum
Détecteurs (à infrarouges IR500; d’ouverture DC500) 16
Sirène HP500; IS500 2
Télécommandes RC500 4
ATTENTION:
Ce document contient seulement quelques indications essentielles sur le
produit.
Pour obtenir des informations détaillées, consulter les manuels des centrales Elkron
capable de gérer l’extension ER500.
1
MONTAGE
L’extension radio ER500 peut être positionnée ou à l’intérieur de la centrale (consulter la
manuelle installation de la centrale) ou à l’intérieur d’un boitier mural type CP/EXP cod.
MP4J00111 en position Size 1 (consulter la documentation du boitier).
A l’intérieur de la centrale peut être logée seulement une extension radio ER500.
Il s’agit de un dispositif radio, pourtant l’extension doit être installé en tenant compte de
toutes les précautions typiques de telles installations.
En cas d’installation dans le boitier CP/EXT, il doit être positionné:
dans un lieu intérieur qui ne soit pas de passage
,
dans un lieu à l’abri de sautes excessives de température
dans un lieu protégé par un système anti-intrusion
,
éloigné de champs électromagnétiques puissants.
2 BORNES, TOUCHES E LED
Description
+ Alimentation de l’extension via le bus
+D
D Transmission des données via le bus
Alimentation de l’extension via le bus
A
Tamper Entrée pour le microswitch de protection du boitier CP/EXP
Touche
B LED Jaune Touche et LED pour l’acquisition de l’extension.
LED verte
signalisation de fonctionnement (pour des détails voir le manuel
de programmation)
Clignotante lente = condition de normal fonctionnement
Clignotante rapide = signalisation de perte de connexion avec la
centrale pour plus que 1 minute.
C
Cavalier Cavalier pour l’exclusion de l’autoprotection
(cavalier inséré = autoprotection exclue)
D LED verte signalisation de fonctionnement du module radio
3
RACCORDEMENT DU BUS ET DU TAMPER
L’extension peut être branchée sur le bus en cascade, en étoile ou en mode mixte.
Un positionnement de l’extension loin du bus n’a pas d’importance.
Raccorder l’extension au bus en utilisant les bornes “+”; “+D”; “D”; “”.
Pour le câblage, utiliser un câble blindé à 4 conducteurs (2 pour l’alimentation et 2 pour
les données). Dans l’estimation générale de la consommation du système, considérer la
consommation max. de l'extension.
Pour l’installation dans le boitier CP/EXT raccorder le microswitch d’autoprotection du
boitier aux bornes de connexion de l’extension.
4
ACQUISITION DE L’EXTENSION
Acquérir l’extension en appuyant sur la touche “B”.
Pour des informations complémentaires sur la procédure d’acquisition, consulter le
manuel d’installation de la centrale.
5
CARACTERISTIQUE TECHNIQUE
Tension nominale d’alimentation: 13.8 Vcc (prélevés à l’aide du bus)
Tension de fonctionnement: 9 Vcc ÷ 15 Vcc
Courant nominale d’alimentation à 12 Vcc : 35 mA
Courant maximale d’alimentation (pic): 45 mA
Longueur max. de la ligne Bus série
Centrale – extension radio: 400 m
Technologie de communication: Radiofréquence bidirectionnelle
Modalité de communication radio: FSK
Fréquence: 868,35 MHz
Nombre canaux radio: 1
Portée radio: > 100 m en champ libre
Température de fonctionnement déclarée: -5 °C ÷ +40 °C
Humidité relative de fonctionnement: 95 % a +40 °C
Protection anti-ouverture boîtier: Autoprotection contre le sabotage
(tamper)
DS80WL50-001B LBT80735


Produkt Specifikationer

Mærke: Elkron
Kategori: Sikkerhed
Model: ER500

Har du brug for hjælp?

Hvis du har brug for hjælp til Elkron ER500 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Sikkerhed Elkron Manualer

Elkron

Elkron 80TC4L00133 Manual

26 August 2024
Elkron

Elkron IR600VC Manual

26 August 2024
Elkron

Elkron 80TC9M00133 Manual

26 August 2024
Elkron

Elkron ELR600RT-20 Manual

26 August 2024
Elkron

Elkron IT500CLOUD Manual

26 August 2024
Elkron

Elkron ER600 Manual

26 August 2024
Elkron

Elkron HPA702L Manual

26 August 2024
Elkron

Elkron 80TH5600133 Manual

26 August 2024
Elkron

Elkron EL100RT Manual

26 August 2024
Elkron

Elkron IRP600 Manual

26 August 2024

Sikkerhed Manualer

Nyeste Sikkerhed Manualer