ENTES EPM-04C-96 Manual
ENTES
Måleudstyr
EPM-04C-96
Læs nedenfor 📖 manual på dansk for ENTES EPM-04C-96 (4 sider) i kategorien Måleudstyr. Denne guide var nyttig for 12 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/4
1
MULTIMETER
EPM-04 / 04C / 04CS
INDEX
Precautions for Installation and Safe Usage.........................................................................1
Front Panel and Usage of Buttons.............................................................................1
General Information and Applications.............................................................................1
Using the Buttons............................................................................................2
Transformer Menu (Ctr / trn / Utr / ConnECtýon) ........................................................................2
User Password Settings (Pin Menu).......................................................................2
Act ivat ing the User Password (Pin Act Menu)......................................................2
Changing the User Password (Pin CHg Menu).........................................................2
Output Setting Menu ..............................................................................3
Current Setting Menu (SP Current Menu) ................................................................3
High/Low Current Settings (SP Cur Hý, SP Cur Lo Menu)..........................................3
Hysteresis Sett ings for High/Low Currents (I-H Hys, I-L Hys Menu).................3
Delay-on Time for High/Low Current s (I-H ond, I-L ond Menu)..............................3
Delay-off Time for High/Low Currents (I-H ofd, I-L ofd Menu).......................................3
Start and Auto Function (StArt dEL and Auto rSt Menu).........................................4
Instant Trip Function (CUr ýnS trP Menu).................................................................4
Voltage Setpoint Menu (SP Volt Menu) ..................................................................4
High/Low Voltage Set tings (SP UoL Hý, SP UoL Lo Menu)..................................4
Hyst eresis Sett ings f or High/Low Volt ages (U-H Hys, U-L Hys Menu)............5
Delay-o n T im e f or High/ Low Vo ltages (U-H ond, U-L ond Menu).. ... ... .....5
Delay-of f Time f or High/Lo w Volt ag es (U-H of d, U-L of d Menu)...... ....... ...5
Frequency Menu .........................................................................................................6
High/Low Frequency Set tings (Frq Hý, Frq Lo Menu).............................................6
Hysteresis Settings for High/Low Frequencies (F-H HyS, F-L HyS) ..............................6
Delay-on / Delay-off T ime for Hig h/Low Frequencies (Frq ond , Frq oFd )....6
Phase Sequence (Voltage Sequence Menu) and Instant Trip (UoL ýnS trP Menu) Menu ........6
Erasing the Max., Min. and Max. Demand Values (Reset Menu)........................6
Demand Time for Demand and Max. Demand (dE tý Menu)....................................................7
Communication Menu (RS-485) .........................................................................7
Technical Features and Default Factory Settings ................................................................7
Connection Diagram ................................................................................................8
Output, SP Current and SP Volt menus are available for EPM-04C/04CS; RS-485 menu
is available for EPM-04CS.
Dimensions
General information
EPM-04/04C/04CS is designed for measuring Phase current, frequency, neutral
cur r e nt and vol tag e s (Phase -Pha se and Pha se-Neut r al) in a
3-Phase system.
EPM-04C/04CS;
Device has 2 warning
output
which named as Out1 and Out2. (NO-Normally
Open) Please refer to Output menu for the functions of the relays.
Connection Diagram
MULTIMETER
EPM-04 / 04C / 04CS
8
A4034 / Rev.8
Available only for EPM-04C/04CS
Available only for EPM-04CS
Panel Cut-out
91mm
91mm
Type PR 19 (96x96)
70mm
Wall 79.3mm
90mm
Tip 19
50mm
1 .......
Phase LEDs:The LEDs turn on when the voltage value, which is applied
to one of the current inputs, reach 30 V
2 ....... First displays k LED (for L1). Measurement parameter is the unit of kilo
when LED is turned on. ie: kA, kV
3 ....... Display for
L1.
4 ....... Second displays k LED (for L2). Measurement parameter is the unit of kilo
when LED is turned on. ie: kA, kV
5 ....... Display for
L2.
6 ....... Third displays k LED (for L3). Measurement parameter is the unit of kilo
when LED is turned on. ie: kA, kV
7 ....... Display for
L3.
8 ....... Displays network frequency when Hz LED is turned on.
9 ....... LED for neutral current. Measurement parameter is displayed in unit of k
kilo when this LED is turned on.
10 ....... Display for neutral current and frequency (for EPM-04C/04CS).
11 .......First warning output LED (Out1). Turned on when the output is activated.
12 .......Second warning output LED (Out2). Turned on when the output is activated.
13 .......Over current / voltage warning output for L1. (EPM-04C/04CS)
14 .......Low current / voltage warning output for L1. (EPM-04C/04CS)
15 .......Over current / voltage warning output for L2. (EPM-04C/04CS)
16 .......Low current / voltage warning output for L2. (EPM-04C/04CS)
17 .......Over current / voltage warning output for L3. (EPM-04C/04CS)
18 .......Low current / voltage warning output for L3. (EPM-04C/04CS)
19 ....... Over current / frequency warning output for frequency and neutral current
(EPM-04C/04CS).
20 .......Low current / frequency warning output for frequency and neutral current
(EPM-04C/04CS).
21 .......Monitoring the L1, L2, L3 voltages values when V LED is turned on and
displays the frequency in 4th display.
22 .......Monitoring the L1, L2, L3 currents values when A LED is turned on and
displays the neutral current in 4th display.
23 ....... Indicates the activating delta connection when is turned on. Neutral
current protection is disactivated even if is activated.
24 ....... LED for max. instant current and voltage. Max. instant currents and H
voltages are displayed when this LED is turned on.
25 ....... LED for min. instant current and voltage. Min. instant currents and L
voltages are displayed when this LED is turned on.
26 ....... LED for max. demand. Max. demand values are displayed when this M
LED is turned on.
27 .......SET button. It is used to enter into the menu and to save the values.
If SET button is pressed for 3 sec. in the measurement mode, you can
enter into menus. This button is used for monitoring the max. (H), Min.
(L) current values and max. demand values in measurement mode.
28 ....... Downward selection button.
29 .......Upward selection button.
30 .......
ESC button. Escaping from the menu. And also used for switching off the
Latch function while this function has activated.
Failure to follow those instructions will result in death or serious injury.
- Disconnect all power before working on equipment.
- When the device is connected to the network, do not remove the front
panel.
- Do not try to clean the device with solvent or the like.Only clean with dry
cloth.
- Verify correct terminal connections when wiring.
- Electrical equipment should be serviced only by your component seller.
- Only for rack panel mounting.
- Fuse must be F type and limit value doesnt exceed 1A.
- No responsibility is assured by manufacturer or any of its subsidiaries
for any consequences arising out of the use of this material.
~
Un
Out 2 Out 1
PK-26
I
L3
I
L2
I
L1
k l
K L
k l
K L
kl
K L
L1 L2 L3 N
GND A B TR
N
L1
L2
L3
1
A
Current Measurement
Inputs
Auxiliary
Supply
Relay utputo
System
Choose according to
contactor current
Voltage Measurement
Inputs
RS485
70mm
79.3mm
90mm
Type PR 19 (96x96)
96mm
96mm
60.6
106.0
10.8 30.1 7.6 9.5
26.5 21.5
53.0
58.0
10.0
8.5
14.0
45.0
90.0
Type PK 26
*
**
12 4 63 5 7
8 9
10
19 20
30
27
28 29 25
24
26
21 22 23
12 11
17
18
15
16
13
14
2
3
4
5
6
7
8
9
10
15
17
19
18
16
13
14
2021 22 23
27
25
24
30
28
29
26
1 11 12
Note: For CT-25 models:
PR-19
k l
K L
k l
K L
k l
K L
IL1 IL2 IL3
Out 1 Out 2 GND B A TR
17 18 19 20
RS485
System
N
L1
L2
L3
1 A
L1
L2
L3
N
Current Measurement Inputs
Auxiliary
Supply
1 2 3 4 5 6
11 12
Output Relay
13 14 1 165
Choose according to
contactor current
7 8 9 10
Voltage Measurement Inputs
In CT-25 (120A) compliant models, only CT-25 current transformer
must be used.
Other type of CTs have a high risk to damage to device.
PRECAUTIONS FOR INSTALLATION AND SAFE USE
Summary of the Contact Operations
Voltage
Frequency
Current
Phase Seq.
Voltage
Frequency
Current
Under
Under
Under
Over
Over
Over
ALTERNATIVE 2 (H-L)
Current
Voltage
Frequency
Phase Seq.
Under/Over
Under/Over
Under/Over
ALTERNATIVE 1 (U-I)
Out 1
Out 2
-->
-->
-->
-->
-->
-->
-->
-->
-->
Valid for EPM-04C/04CS
k: When CT-25 is used, Red cable is connected to k terminal.
l: When CT-25 is used, Black cable is connected to l terminal.
Produkt Specifikationer
Mærke: | ENTES |
Kategori: | Måleudstyr |
Model: | EPM-04C-96 |
Har du brug for hjælp?
Hvis du har brug for hjælp til ENTES EPM-04C-96 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Måleudstyr ENTES Manualer
28 August 2024
28 August 2024
28 August 2024
28 August 2024
28 August 2024
28 August 2024
24 August 2024
24 August 2024
24 August 2024
24 August 2024
Måleudstyr Manualer
- Måleudstyr Bosch
- Måleudstyr SilverCrest
- Måleudstyr Beurer
- Måleudstyr Panasonic
- Måleudstyr Hager
- Måleudstyr Owon
- Måleudstyr DeWalt
- Måleudstyr Extech
- Måleudstyr Silverline
- Måleudstyr IFM
- Måleudstyr Victron Energy
- Måleudstyr Pioneer
- Måleudstyr Finder
- Måleudstyr Mitsubishi
- Måleudstyr Metrix
- Måleudstyr ProfiCare
- Måleudstyr TFA
- Måleudstyr Soler & Palau
- Måleudstyr Nedis
- Måleudstyr Milwaukee
- Måleudstyr BENNING
- Måleudstyr Wago
- Måleudstyr Kyoritsu
- Måleudstyr Fysic
- Måleudstyr Microlife
- Måleudstyr Topcom
- Måleudstyr Laserliner
- Måleudstyr Trotec
- Måleudstyr Einhell
- Måleudstyr Honeywell
- Måleudstyr Megasat
- Måleudstyr Soehnle
- Måleudstyr REV
- Måleudstyr Carrier
- Måleudstyr Danfoss
- Måleudstyr Eberle
- Måleudstyr Bresser
- Måleudstyr Goobay
- Måleudstyr Digitus
- Måleudstyr Alecto
- Måleudstyr Ansmann
- Måleudstyr Westfalia
- Måleudstyr Homedics
- Måleudstyr Basetech
- Måleudstyr Lanaform
- Måleudstyr Grohe
- Måleudstyr Voltcraft
- Måleudstyr Testboy
- Måleudstyr Omnitronic
- Måleudstyr Velleman
- Måleudstyr FLIR
- Måleudstyr Perel
- Måleudstyr Vemer
- Måleudstyr ORNO
- Måleudstyr Amprobe
- Måleudstyr Technoline
- Måleudstyr Fluke
- Måleudstyr Stabila
- Måleudstyr Shimano
- Måleudstyr Laica
- Måleudstyr Techno Line
- Måleudstyr Ridgid
- Måleudstyr Midland
- Måleudstyr Monacor
- Måleudstyr Elgato
- Måleudstyr Hazet
- Måleudstyr LogiLink
- Måleudstyr Testo
- Måleudstyr Be Cool
- Måleudstyr GW Instek
- Måleudstyr GoClever
- Måleudstyr LaCie
- Måleudstyr Rossmax
- Måleudstyr Ideal
- Måleudstyr Multimetrix
- Måleudstyr Eurolite
- Måleudstyr Eltako
- Måleudstyr Tempest
- Måleudstyr Meec Tools
- Måleudstyr Brüder Mannesmann
- Måleudstyr Eastron
- Måleudstyr Clean Air Optima
- Måleudstyr Vimar
- Måleudstyr Continental Edison
- Måleudstyr Klein Tools
- Måleudstyr Oregon Scientific
- Måleudstyr PeakTech
- Måleudstyr Dahua Technology
- Måleudstyr Uni-T
- Måleudstyr Reely
- Måleudstyr Joy-It
- Måleudstyr HT Instruments
- Måleudstyr Kübler
- Måleudstyr TrueLife
- Måleudstyr Kern
- Måleudstyr Chauvin Arnoux
- Måleudstyr Kogan
- Måleudstyr Delta Ohm
- Måleudstyr Megger
- Måleudstyr Peak
- Måleudstyr Werma
- Måleudstyr Kemo
- Måleudstyr TDE Instruments
- Måleudstyr H-Tronic
- Måleudstyr Holzmann
- Måleudstyr ClimeMET
- Måleudstyr Adwa
- Måleudstyr Gossen Metrawatt
- Måleudstyr Lund
- Måleudstyr Yato
- Måleudstyr Beha-Amprobe
- Måleudstyr Cocraft
- Måleudstyr Emko
- Måleudstyr Hikmicro
- Måleudstyr Sonel
- Måleudstyr Murideo
- Måleudstyr Seaward
- Måleudstyr SRS
- Måleudstyr Toolland
- Måleudstyr VirtuFit
- Måleudstyr AS - Schwabe
- Måleudstyr IHealth
- Måleudstyr Fantini Cosmi
- Måleudstyr Sekonic
- Måleudstyr Eizo
- Måleudstyr Wentronic
- Måleudstyr Comark
- Måleudstyr Livington
- Måleudstyr Maximum
- Måleudstyr Tektronix
- Måleudstyr SIIG
- Måleudstyr Muller
- Måleudstyr TFA Dostmann
- Måleudstyr Greisinger
- Måleudstyr YSI
- Måleudstyr Kreg
- Måleudstyr Pancontrol
- Måleudstyr X-Rite
- Måleudstyr Ebro
- Måleudstyr Arya
- Måleudstyr RK Technology
- Måleudstyr Aktobis
- Måleudstyr KS Tools
- Måleudstyr Trumeter
- Måleudstyr Aeros
- Måleudstyr Aqua Master Tools
- Måleudstyr Hanna
- Måleudstyr Atmel
- Måleudstyr Qualita
- Måleudstyr MGL Avionics
- Måleudstyr AREXX
- Måleudstyr PCE Instruments
- Måleudstyr UHoo
- Måleudstyr CEM
- Måleudstyr SHX
- Måleudstyr Hameg
- Måleudstyr CESYS
- Måleudstyr Circutor
- Måleudstyr Wachendorff
- Måleudstyr Duro Pro
- Måleudstyr Aerospace Logic
- Måleudstyr Zircon
- Måleudstyr BJZ
- Måleudstyr Johnson Level
- Måleudstyr GMW
- Måleudstyr SOEKS
- Måleudstyr Apollo Ultrasonic
- Måleudstyr Softing
- Måleudstyr Weltron
- Måleudstyr Oscium
- Måleudstyr Janitza
- Måleudstyr Sanwa
- Måleudstyr Condtrol
- Måleudstyr J.P. Instruments
- Måleudstyr Weidmüller
- Måleudstyr Qubino
- Måleudstyr Lascar Electronics
- Måleudstyr P3 International
- Måleudstyr Beckmann & Egle
- Måleudstyr Seek Thermal
- Måleudstyr INFICON
- Måleudstyr Motrona
- Måleudstyr Tempo
- Måleudstyr Camille Bauer
- Måleudstyr Blebox
- Måleudstyr HOZO Design
- Måleudstyr Corentium
- Måleudstyr GQ
- Måleudstyr Dostmann Electronic
- Måleudstyr SecuTech
- Måleudstyr NetPeppers
- Måleudstyr SensoProtect
- Måleudstyr Water-i.d.
- Måleudstyr ZKETECH
- Måleudstyr LabNation
- Måleudstyr Electronics International
- Måleudstyr Cliff
- Måleudstyr Fixpoint
- Måleudstyr AkYtec
- Måleudstyr Stahlwille
- Måleudstyr MASIMO
- Måleudstyr Milesight
- Måleudstyr Enda
- Måleudstyr Ermenrich
- Måleudstyr Noyafa
- Måleudstyr Stamos
Nyeste Måleudstyr Manualer
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024