Model 380405- - _V 4 5/ en GB 1. 18
User Manual
Capacitance Decade Box
Model 380405
Introduction
Congratulations on your purchase of the Extech Capacitance Decade Box. This 380405
device oers 5 decades of capacitance ranges from 100pF to 11.111uF (in 100pF steps).
Slide switches allow easy addition and subtraction of capacitance values. Binding posts (3)
oer simp and secure connections. Careful use of this decade box will provide years of le
reliable service.
Specications
Capacitance ranges 100pF to 11.111uF in 100pF steps
Internal Residual Cap 50pF maximum :
Voltage limit 50VDC ( -polarized capacitors) non
Connection Three (3) binding posts
Accuracy 5% (< =1uF: 1kHz test frequency; > 1uF: 100Hz test frequency)
Operating conditions Temperature: 0 to 50oC (32 to 122oF) / Humidity: < 80%RH
Dimensions/Weight 7 x 11.7 x 3.3 (5.79 x 4.61 x 1.3") Approx. 312g (0.69 lbs) 14. cm /
Operation
Binding Post Connections
The binding posts can be used for connections in several ways:
1. A banana plug can be inserted directly into the posts.
2. Bare wire can be threaded through the post after it has been unscrewed. Once the bare wire is threaded, tighten the posts as necessary.
3. Alligator clips can be used but use caution not to strip the post threads or plastic post housing.
The Capacitance output is available on the RED and the BLACK binding posts. The WHITE post is case ground and is typically not used. Connect the
positive lead of the device under test to the RED post. Connect the negative lead to the BLACK post. Use the WHITE grounding post only if the device
under test will be grounded to the 380405 case.
Range Selection
The front panel switches are used to select the capacitance that will be output on the RED and BLACK terminals. When a switch is set to the IN 20
position, the value printed above the switch is added to the total capacitance available at the posts. When the switch is set to OUT it is excluded from
the total capacitance. If all of the switches are set to OUT, the total output capacitance will be zero (+ 50pF residual capacitance ). approx
For example, if the desired output value is 10.5uF, set the following switches to the IN position: 4uF, 3uF, 2uF, 1uF, 0.4uF, and 0.1uF.
Testing
This device can be used to verify the calibration integrity of multimeters, LCR meters, calibrators, etc. Connect as described in the Binding Post
Connections section above, and then set the capacitance switches to output the desired capacitance. Ensure that the voltage supplied by the device
under test is not greater than 50VDC. The device under test should read the value of capacitance selected on the tester. If it does not, the device
under test may need calibration, adjustment, or repair.
Copyright 2013-2018 FLIR Systems, Inc. ©
All rights reserved including the right of reproduction in whole or in part in any form
ISO-9001 Certified
www.extech.com


Produkt Specifikationer

Mærke: Extech
Kategori: Ikke kategoriseret
Model: 380405

Har du brug for hjælp?

Hvis du har brug for hjælp til Extech 380405 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Extech Manualer

Extech

Extech 380580 Manual

22 Oktober 2024
Extech

Extech CO220 Manual

27 September 2024
Extech

Extech MO57 Manual

18 September 2024
Extech

Extech HD750 Manual

13 September 2024
Extech

Extech 380396 Manual

1 September 2024
Extech

Extech HDV600 Manual

1 September 2024
Extech

Extech 380395 Manual

1 September 2024
Extech

Extech HDV540 Manual

28 August 2024
Extech

Extech 380260 Manual

28 August 2024
Extech

Extech CO100 Manual

11 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Smeg

Smeg KIT6PX Manual

23 December 2024
Smeg

Smeg KIT6CX Manual

23 December 2024
Smeg

Smeg GTA-6 Manual

23 December 2024