User's Guide
Model 42270 Temperature & Humidity Datalogger
Model 42260 Temperature Datalogger
Introduction
Congratulations on your purchase of the Extech Datalogging Module. The following
models are covered in this manual.
Model 42270: Temperature and Humidity Datalogging Module
Model 42260: Temperature-only Datalogging Module
The Dataloggers can be used to monitor the temperature of greenhouses,
warehouses, food transports, aircraft cabins, refrigerated trucks, containers,
museums, and HVAC equipment. The Model 42270 records Relative Humidity
readings in addition to temperature readings. Instructions on how to program the
dataloggers are not included this manual. Programming and data retrieval
instructions are included in the 42275, 42265, 42276 and 42266 kits.
Description
1. Mounting hole
2. Status LEDs (Record and Alarm)
3. LCD display
Displays
LCD Display
REC: Displayed while logging readings.
HI and LOW: Displayed when the High or Low Alarm limit is exceeded.
RH%: Relative Humidity (42270 only)
C or F: Temperature units.
COMM: Appears when Datalogger is communicating with a PC.
Recording Status Indication
Both the RED status LED and the display indicator ‘REC’ will ash every 5 seconds if
the sampling rate is set to 5 seconds or higher. If the sampling rate is set lower than 5
seconds, the indicators will ash every 1, 2, 3, or 4 seconds as programmed.
ALARM Status Indication
Both the YELLOW status LED and the display indicator ‘ALM’ will ash when the
recorded value is higher than the user programmed High Alarm value or lower than the
Low Alarm value. The Alarm status LED and the ‘ALM’ display indicator flash every 5
seconds if the sampling rate is programmed for 5 seconds or higher. If the sampling
rate is set lower than 5 seconds, the indicators will ash every 1, 2, 3, or 4 seconds as
programmed.
Low Battery Indication
When the lithium battery voltage nears the critical operating level, the LCD displays
‘LO’. To replace the battery, refer to the Battery Replacement section of this manual.
Specications
Front panel status LEDs Two (2): RECORD and ALARM
Temperature range -40 to 85°C (-40 to 185°F)
Temperature resolution 0.1° up to 99.9°; 1° from 100° to 185°
Temperature accuracy ±0.6°C (1.2°F) from -20 to 50°C (-4 to 122°F)
±1.2°C (2.4°F) all other ranges
Humidity range & accuracy 0.0 to 99.9% Relative Humidity; Accuracy: ± 3%
Datalogger Memory 16,000 temperature readings (8,000 temperature and
8,000 humidity readings on the 42270)
Sampling rate Programmable from 1 to 7200 seconds (2 hours)
Power supply One 3.6V ½ ‘AA’ lithium battery
Battery Life 1 year: 5 second sample rate in sleep mode
3.8 months: 24 hour sample rate in non-sleep mode
Low battery Indicator Display shows ‘LO’
Dimensions 76.2 x 57.2 x 22.3mm (3 x 2.3 x 0.88")
The datalogger display will not switch on
until activated by software or the printer
programmer.
THESE DATALOGGERS CANNOT BE USED WITHOUT THE
SOFTWARE FROM KIT 42275 (42265) OR THE PRINTER
PROGRAMMER 42276 (42266).
Battery Replacement
When the low battery icon (‘LO’) appears on the LCD display, replace the Lithium CR2
battery.
1. Open Datalogger housing by rst removing the four (4) rear Phillips screws.
2. Carefully pry off the rear of the Datalogger.
3. The cylindrical lithium battery is located on the bottom of the PCB board.
4. Replace the battery, observing polarity.
5. Assemble the Datalogger housing.
You, as the end user, are legally bound (Battery ordinance) to return all
used batteries and accumulators; disposal in the household garbage
is prohibited!
You can hand over your used batteries / accumulators at collection
points in your community or wherever batteries / accumulators are sold!
Disposal: Follow the valid legal stipulations in respect of the disposal of
the device at the end of its lifecycle
Copyright 2008 Extech Instruments Corporation©
All rights reserved including the right of reproduction in whole or in part in any form.
42270_42260-EU-EN V2.2 7/09
Produkt Specifikationer
Mærke: | Extech |
Kategori: | Måling |
Model: | 42270 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Extech 42270 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Måling Extech Manualer
22 Oktober 2024
22 Oktober 2024
6 April 2024
4 April 2024
23 Marts 2024
4 Marts 2024
18 Februar 2024
31 Januar 2024
19 Januar 2024
4 Januar 2024
Måling Manualer
- Måling Bosch
- Måling SilverCrest
- Måling Hager
- Måling DeWalt
- Måling Silverline
- Måling IFM
- Måling Pioneer
- Måling Finder
- Måling Mitsubishi
- Måling Braun
- Måling Metrix
- Måling TFA
- Måling Garmin
- Måling Pyle
- Måling Güde
- Måling ABB
- Måling Hama
- Måling BENNING
- Måling Smartwares
- Måling Laserliner
- Måling Black And Decker
- Måling Trotec
- Måling Hilti
- Måling Soehnle
- Måling König
- Måling Powerfix
- Måling Flexa
- Måling Festo
- Måling Danfoss
- Måling Bresser
- Måling Alecto
- Måling Contec
- Måling VDO
- Måling Westfalia
- Måling Basetech
- Måling Voltcraft
- Måling Testboy
- Måling Velleman
- Måling FLIR
- Måling Perel
- Måling Vemer
- Måling ORNO
- Måling Amprobe
- Måling Fluke
- Måling Stabila
- Måling Ridgid
- Måling Sun Joe
- Måling ADE
- Måling Projecta
- Måling Hazet
- Måling Park Tool
- Måling Pantone
- Måling Testo
- Måling GW Instek
- Måling Brandson
- Måling Etymotic
- Måling Cablexpert
- Måling Kopp
- Måling Eltako
- Måling Eastron
- Måling Vimar
- Måling Klein Tools
- Måling PeakTech
- Måling Uni-T
- Måling Kübler
- Måling Kern
- Måling Chauvin Arnoux
- Måling Megger
- Måling Peak
- Måling TDE Instruments
- Måling ClimeMET
- Måling Adwa
- Måling Gossen Metrawatt
- Måling Siglent
- Måling Hikmicro
- Måling Pico
- Måling Sonel
- Måling Murideo
- Måling Workzone
- Måling Sauter
- Måling Sikkens
- Måling X4-LIFE
- Måling Tru Components
- Måling Berger & Schröter
- Måling Histor
- Måling PCE Instruments
- Måling MSW
- Måling Crelando
- Måling CSL
- Måling Stamos
- Måling Stelzner
- Måling Dranetz
- Måling Clare
Nyeste Måling Manualer
21 November 2024
21 November 2024
21 November 2024
21 November 2024
21 November 2024
21 November 2024
21 November 2024
21 November 2024
21 November 2024
21 November 2024