User's Guide
Battery/Coolant Refractometer with ATC
Model RF40-C
Introduction
Congratulations on the purchase of your RF40-C Battery/Coolant
Refractometer with automatic temperature compensation. This
precision optical instrument should be handled gently; avoid touching
the optical surface. Careful use of this instrument will provide years of
reliable service.
Description
1. Eyepiece
2. Mirror tube
3. Adjustment Screw
4. Cover plate
5. Prism
Field of View
Copyright © 2006 Extech Instruments Corporation.
All rights reserved including the right of reproduction in whole or in part in any form.
www.extech.com
Version 1.0 March 2006
Operation
The instrument measures the refractive index of the sample.
1. Zero Adjustment
Place one or two drops of distilled water on the prism. Close the cover
plate and rotate the adjusting screw so that the light/dark boundary lines
up with the “waterline”. Once the zero adjustment has been completed,
clean the prism with soft cloth
2. Sample Preparation and Reading
To take a sample reading, simply
place a few drops of a sample liquid
on the measurement prism at the
end of the instrument. Lower the
cover plate onto the sample and
prism. Open the prism cover and
place 2 or 3 drops on the prism.
Close the cover so the liquid spreads
across the entire surface of the prism
without air bubbles or dry spots.
Allow the sample to remain on the prism for approximately 30 seconds.
While holding the instrument under a light source, look through the
eyepiece. The freezing point of the liquid or the state of the battery liquid
is determined by the intersection of the boundary of the light and dark
fields (known as the shadowline) on the printed scale. If the scale
appears out of focus, the eyepiece may be adjusted by rotating the
knurled portion. The instrument also features an eye guard to prevent
stray light from entering the eyepiece and causing reflections.
It may be necessary to adjust the position of the light source to
maximize the contrast of the shadowline. Under normal conditions,
optimal contrast is obtained by holding the instrument underneath and
perpendicular to a light source.
Once a reading has been taken, wipe dry with a clean cloth (do not
wash or rinse) and place the instrument in the supplied plastic case.
Store the instrument in a safe, dry environment.
Temperature is one of the single most important factors influencing
accurate refractometer readings and is one of the largest sources of
error in measurement. Temperature compensation relieves the user of
the responsibility to measure temperature and apply a correction factor
when taking readings. This refractometer makes this correction
automatically. When ambient temperature varies from 20°C (68°F),
readings are automatically adjusted to compensate for temperature
variance between 10°C to 30°C (50°F to 86°F).
Specifications
Range -51 to 0°C (-60 to 32°F) for propylene and
ethylene glycol freeze point
1.10 to 1.40 specific gravity of battery acid
Resolution 1°C/2°F glycol freeze point
0.01 specific gravity of battery acid
Dimensions 6.5x1.5x1.5" (165x38x38mm)
Weight 7.0 oz. (200g)


Produkt Specifikationer

Mærke: Extech
Kategori: Måling
Model: RF40

Har du brug for hjælp?

Hvis du har brug for hjælp til Extech RF40 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måling Extech Manualer

Extech

Extech 380926 Manual

22 Oktober 2024
Extech

Extech 380941 Manual

22 Oktober 2024
Extech

Extech 407113 Manual

6 April 2024
Extech

Extech AUT20 Manual

4 April 2024
Extech

Extech EN100 Manual

23 Marts 2024
Extech

Extech CO10 Manual

4 Marts 2024
Extech

Extech 380193 Manual

18 Februar 2024
Extech

Extech AUT-TLM Manual

31 Januar 2024
Extech

Extech 45118 Manual

19 Januar 2024
Extech

Extech 461880 Manual

4 Januar 2024

Måling Manualer

Nyeste Måling Manualer

Sauter

Sauter FA 20 Manual

21 November 2024
Sauter

Sauter TN EE Manual

21 November 2024
Sauter

Sauter FH 2K Manual

21 November 2024
Sauter

Sauter FA 300 Manual

21 November 2024
Sauter

Sauter FH 50K Manual

21 November 2024
Sauter

Sauter FK 25 Manual

21 November 2024
Sauter

Sauter FH 50 Manual

21 November 2024
Sauter

Sauter FH 5K Manual

21 November 2024
Sauter

Sauter FH 100K Manual

21 November 2024
Sauter

Sauter FH 10 Manual

21 November 2024