IPA T RLY4 • Setup Guide
This guide provides instructions for an experienced installer to install the Extron IPA T RLY4 relay accessory and to make all
connections.
The IPA T RLY4 is an IPLink® Accessory product. The relay accessory consists of four output relays with normally open (when the
relay is de-energized) (NO) and normally closed (NC) contacts.
The relay accessory converts a solid state (up to 12 VDC) signal, from a Flex I/O port or Digital I/O port on an Extron control
processor, to a relay contact closure. The relay contacts can handle up to 24 VAC or 24 VDC as a tally signal, contact closure
signal, or control signal to drive devices in your system, such as a lighting system (see gure 1) or remote screens. The relay
contacts are protected by an overvoltage circuit.
The compact IPA T RLY4 can be concealed out of the way anywhere in your system with the included hook and loop fastener strip.
IPA T RLY4
1 2 3 4 C
INPUT S
PWR OUT = 6W
V C G
VOL
PO WER
12V
1.0A MAX
G
T x Rx
RT S CT S
CO M 1
3
1 2 4 G
DI GIT AL I/O
G
T x R x
CO M 2
-S+V +S G
eB US
C1 2
RE L AY S
SG
IR /S
LAN
AV
LAN
Extron
IPCP Pro 255Q xi
Ethernet Control
Processor
Extron
IPA T RLY4
Relay Accessory
NO C NC NO C NC NO C NC NO C NC
RELAY 1 RELAY 2 REL AY 3 RELAY 4
Lighting System
Front
Rear
Extron
12 V Power
Supply
+12 VDC
(Common)
Figure 1. Typical IPA T RLY 4 Application
Connections
NOTE: The 5-pole captive screw input connector and four 3-pole captive screw output connectors are included with the
unit, but you must supply the cable. Extron recommends the CTL Series cable, available non-plenum and plenum bulk
rolls and plenum pre-cut lengths.
IPA T RLY4 1 2 3 4 C
INPUTS
NO C NC NO C NC NO C NC NO C NC
RELAY 1 RELAY 2 RELAY 3 RELAY 4
AA
BB BB BB BB
Figure 2. IPA T RLY4 Connections
Input Connections
A — Connect the 12 VDC source to the common voltage (C) terminal of the 5-pole captive screw Inputs
connector. Connect the appropriate terminal (1 though 4) to the digital output or flex I/O of the Extron control
processor.


Produkt Specifikationer

Mærke: Extron
Kategori: Ikke kategoriseret
Model: IPA T RLY4

Har du brug for hjælp?

Hvis du har brug for hjælp til Extron IPA T RLY4 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Extron Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Gigabyte

Gigabyte ODIN GT 550W Manual

23 November 2024
Stamos

Stamos S-PLASMA 60U Manual

23 November 2024
Velbus

Velbus VMBPIRO-W-20 Manual

23 November 2024
Honor

Honor 90 Pro Manual

23 November 2024
Honor

Honor 80 SE Manual

23 November 2024
Medela

Medela Safe & Dry Manual

22 November 2024
Jane

Jane First Potty Manual

22 November 2024