Ferguson FS2SD Manual


Læs nedenfor 📖 manual på dansk for Ferguson FS2SD (2 sider) i kategorien Røgalarm. Denne guide var nyttig for 18 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
3
4
2
5 6
7 8 9
Smoke Detector
User Manul
*Please read the user manual carefully before operation.
FS2SD
EN
Product introduction
This product is a photoelectric smoke Detector. It is
a warning device, cannot sense gas, heat, or flame,
cannot prevent or put out fire. It is capable of
real-time detecting the presence of smoke,
detection of visible particles (smoldering fire) faster
than ionization smoke alarms. Red LED flashes
rapidly and detectors sound alarm once detecting
smoke fire danger, can alert you and your family
timely. Smoke alarms should be installed in all
rooms, living room, storage areas, basements and
attics unit where fire may happen.
Specyfication
Sensor Bracket
Tips
1.This device is designed specifically for home use, may not to
able to provide sufficient fire alert for public areas.
2.Please avoid installation in bathrooms and other very humid
places, dusty or greasy areas, or very airy place with air
conditioning, ceiling fans, etc.
3.Please keep device clean, and do not let dust to accumulate. It
is recommended to clean every 6 months with a household
cleaner and a soft brush.
4.The effective lifespan is 10 years. Replacement every 10 years,
regardless of breakdown or not.
5.Please pay attention if it alarms. Besides proper use of alarm,
we should also strengthen the consciousness of fire safety.
Test/Hush Button
and LED indicator
Ceiling mounting
Sloping ceiling mounting
Recommended and Avoided
Instalation Position
Sloping Ceiling Mounting
Position
Instalation Renderings
l
Area that air does not flow
Ceiling Centre
The preferred location to install smoke alarm is in the centre of the ceiling
because Smoke, heat and combustion products rise to the ceiling and
will lateral spread. Keep at least 30 cm distance from lights or
decorations, and at least 15 cm away from walls and corner. If hall is
more than 12 meters wide, please install at 2 sides of the hall.
If ceiling is sloping, please install the smoke alarm at horizontal distance
90cm away from the ceiling top.
Anticlockwise rotating the bracket out from the installation
base, then remove the battery insulating strip to make
device on power.
Remove the double-sided adhesive membrane on the
mounting bracket, and rotating the smoke alarm into
the bracket.
1
2
3
4
1. Operating voltage: DC3V(CR123A Lithium Battery)
2. Static current: ≤ 10µ A
3. Alarm current: ≤ 60mA
4. Sound level: 85dB/3m
5. Working Temperature: -10 ~+50
°C
6. Working humidity: ≤ 95%RH
7. Dimension: 60*60*49.2mm
Select the Smart Hub from the list of devices to which you want to
add a new device (sensor) or device with factory settings restored.
1.Click add devices on APP, entering networking mode.
Adding device
When the LED in the control
panel blinks blue, we confirm
and go to pairing devices.
2. According to the tips on APP, keep pressing networking
button, green LED flashes quickly, tips appear on APP,
green LED keep on for 3 seconds, network success.
Delete device
In the application, click and hold the selected device, the "delete
device" command will be displayed. After removed it, disconnect
the network connection device by pressing and holding the pairing
button. 6-fold LED blink in green means disconnection of the
sensor network from the HUB.