Hinweis, Note, Information. . . . . . . . . . . . . . . . . . . . . . . . . .
de Einbau und Inbetriebnahme nur von qualifiziertem
Fachpersonal, gemäß Bedienungsanleitung.
en Fitting and commissioning to be carried out by
qualified personnel only in accordance with the
operating instructions.
sv Montering och idrifttagning får endast utföras av
auktoriserad fackkunnig personal i enlighet med
denna bruksanvisning.
Only for use in Class 2 Circuits
This device is intended to be used with a Class 2 power
source or Class 2 transformer in accordance with UL1310 or
UL1585.
As an alternative a LV/C (Limited Voltage/Current) power
source with one of the following properties can be used:
This device shall be used with a suitable isolating source
such that the maximum open circuit voltage potential
available to the product is not more than 24 V DC and the
current is limited to a value not exceeding 8 amperes
measured after 1 minute of operation.
This device shall be used with a suitable isolating source
in conjunction with a fuse in accordance with UL248. The
fuse shall be rated max. 4 A and be installed in the
24 V DC power supply to the device in order to limit the
available current.
In determining the acceptability of the combination, the
following detail should be examined:
These devices are intended and investigated for use with
CP String from Festo Programmable controllers only.
Bild 2 / Fig. 2
Bild 1 / Fig. 1
1
2
3
4
5
4
Gruppe, Group,
Grupp
6
7
8
9
CPI-Modul CP-E16-M12-EL (16E) de..........................
1 Funktion
Das CPI-Modul CP-E16-M12-EL ist ausschließlich bestimmt
r den Einsatz an einem CP-Strang von Festo. CPI-/CP-
Module sind nur folgendermaßen zu benutzen:
– bestimmungsgemäß
im Originalzustand, ohne eigenmächtige Veränderungen
in technisch einwandfreiem Zustand
Das CPI-Modul CP-E16-M12-EL unterstützt CPI-Systeme mit
erweiterter Funktionalität.
2 Anwendung
Es sind die angegebenen Grenzwerte für Temperaturen, elek-
trische Daten, Drehmomente usw. einzuhalten. Aushrliche
Informationen finden Sie in der Beschreibung
Typ P.BE-CPEA-CL-... (Kombinierte Beschreibung für CP-CL und
CP-EL-Module).
3 Einbau und Inbetriebnahme
Hinweis..................................................
Schalten Sie vor Installations- und Wartungsarbeiten
folgendes aus:
– Druckluftversorgung
Betriebs- und Lastspannungsversorgung.
Befestigung des Moduls: Mit integrierter Hutschienenbefe-
stigung (mit beigegtem Befestigungs-Set) oder Wand-
montage.
Befestigung der Schilderträger 6: An integrierten Auf-
stecknuten an Längs- und Schmalseite. Schilderträger 9
können Sie über die Teilenummer 547473 (Typ ASCF-H-E2)
bestellen.
Wenn Sie in einem CP-Strang ein CPI-Modul einsetzen wollen
gehen Sie wie folgt vor:
CPI-Modul montieren.
CP-Kabel anschließen.
Spannungsversorgung am CPI-Master einschalten.
Automatische Erkennung der Strangbelegung am CPI-
Master mit SAVE-Taste oder DIL-Schalter durchführen.
Beachten Sie die Anwenderdokumentation des Masters.
CPI-Master neu starten (Power OFF/ON).
Bild 1 zeigt die Modulmaße. Die he des Moduls beträgt
ca. 30 mm.
Bild 2 zeigt die Anschsse des Moduls CP-E16-M12-EL:
Bild 2 Anschluss Pinbelegung
1CPI In (M9, Stecker, 5 polig) -
2CPI Out (M9, Buchse, 5 polig) -
3Erdung FE
4Sensor (8x M12, Buchse, 5 polig) Pin 1: +24V DC
Pin 2: Eingang Ex+1
Pin 3: 0 V
Pin 4: Eingang Ex
Pin 5: FE
4 Diagnose über LEDs 5
5
5
55
Das CPI-Modul CP-E16-M12-EL ermöglicht eine Gruppendia-
gnose und Gruppenüberwachung der Sensorspannung. Eine
Gruppe besteht aus 4 Eingängen.
LED Betriebszustand und Fehleranzeige
PS
(
ü
)
Anzeige CPI-Kommunikations
S
(
B
i
b
leuchtet: Kommunikation OK
(grün) Status (Betriebsspannungs-
v
e
r
s
o
r
g
u
n
g
P
n
1
)
blinkt: Unterspannung
versorgung, Pin 1
)
aus: Betriebsspannung liegt
nicht an
0 ... 15
(
ü
)
Kanalweise Anzeige Status
d
E
i
ä
(
6
)
leuchtet: Signaleingang
(grün) der Eingänge (16x) aus: kein Signaleingang
P
(rot)
Modulweise Anzeige(1x) von
Kurzschluss/Überlast 7
leuchtet: Kurzschluss/Über-
last
(
r
o
t
)
K
u
r
z
s
c
h
l
u
s
s
/
Ü
b
e
r
l
a
s
t
7
aus: kein Kurzschluss/Über-
last
P
(rot)
Gruppenweise Anzeige (4x)
von Kurzschluss/Überlast 8leuchtet: Kurzschluss/Über-
last
(
r
o
t
)
v
o
n
K
u
r
z
s
c
h
l
u
s
s
/
Ü
b
e
r
l
a
s
t
8
aus: kein Kurzschluss/Über-
last
5 Technische Daten
Bezeichnung Erläuterung/Werte
Digitale Eingänge 16 Eingänge nach IEC 61131
Typ 2, PNP
Potenzialtrennung
zwischen Kanälen
zwischen CPi-System
nein
nein
Logik-Stromaufnahme über CPI-
System
max. 75 mA bei 24 V
Max. kapazitive Belastung Sensorver-
sorgung Gruppe (z. B. x1, x2)
100 F bei 130 mAμ
Kurzschlussschutz
Sensorversorgung
Ja, elektronisch
Ansprechschwelle Gruppe max. 0,18 A/Gruppe, träge
Autom. Spannungswiederkehr nach
Kurzschluss
nein
Schutzart (Steckverbinder gesteckt
oder mit Schutzkappe)
IP65 nach EN 60529
Schutz gegen elektrischen Schlag
(direktes und indirektes Berühren
nach IEC/DIN EN 60204-1)
durch PELV-Stromkreis
Elektromagnetische Verträglichkeit
EMV Störaussendung
EMV Srfestigkeit
siehe Konformitätserklärung
!www.festo.com
Schwingung und Schock geprüft nach IEC / EN 60068
Teil 2-6 und 2-27
Zulässige Umgebungstemperatur
– Betrieb
– Lagerung
-5 … +50 °C
-20 … +70 °C
Relative Luftfeuchtigkeit 95 % bei 40 °C,
nicht kondensierend
Erdung (FE)
bei Hutschiene
bei Wandmontage
über Hutschienenbefesti-
gung mittels Klemme (Be-
festigungsset beiliegend)
über Erdungsanschlussblech
mit Erdungskabel
CPI module CP-E16-M12-EL (16I) en..........................
1 Function
CPI module CP-E16-M12-EL is intended exclusively for use on
a CP string from Festo. CPI/CP modules may only be used as
follows:
as designated
without any modifications by the user.
in faultless technical condition
CPI module CP-E16-M12-EL supports CPI systems with ex-
tended functions.
2 Application
The maximum values specified for temperatures, electrical
data, torques etc. must be observed. Detailed information
can be found in the manual
type P.BE-CPEA-CL-... (combined manual for CP-CL and CP-EL
modules).
3 Installation and commissioning
Note......................................................
Before carrying out installation and maintenance work,
switch off the following:
the compressed air supply
the operating and load voltage supplies.
Fastening the module With integrated hat rail fastening
(with fastening set supplied) or wall fitting.
Fastening the inscription plate 6: Onto integrated
clip-in grooves on the long and narrow sides. Inscription
plates 9can be ordered under part number 547473
(type ASCF-H-E2).
If you wish to insert a CPI module in a CP string proceed as
follows:
Fit the CPI module.
Connect the CP cable.
Switch on the power supply on the CPI master.
Carry out automatic recogniton of the string assignment
on the CPI master with the SAVE button or with the DIL
switch. Observe the instructions in the user documenta-
tion for the master.
Start the CPI master again (Power OFF/ON).
Fig. 1 shows the module dimensions. The module is
approx. 30 mm high.
Fig. 2 shows the connections of module CP-E16-M12-EL:
Fig. 2 Connection Pin assignment
1CPI In (M9, plug, 5-pin) -
2CPI Out (M9, socket, 5-pin) -
3Earthing FE
4Sensor (8x M12, socket, 5-pin) Pin 1: + 24 V DC
Pin 2: Input Ex+1
Pin 3: 0 V
Pin 4: Input Ex
Pin 5: FE
4 Diagnosis via LEDs 5
5
5
55
CP module CP-E16-M12-EL enables group diagnosis and
group monitoring of the sensor voltage. A group consists of
4 inputs.
LED Operating status and fault display
PS
(
)
Display of CPI communi-
i
(
i
lights up: Communication OK
(green) cation status (operating
v
o
l
t
a
g
e
s
u
p
p
l
y
p
i
n
1
)
flashes: Undervoltage
voltage supply, pin 1
)
out: Operating voltage not
applied
0 ... 15
(
g
r
e
e
n
)
Channel-by-channel
d
i
s
p
l
a
y
o
f
t
h
e
s
t
a
t
u
s
o
f
t
h
e
lights up: Signal input
(
green
)
d
i
sp
l
ay o
f
t
h
e status o
f
t
h
e
inputs (16x) out: No signal input
P(red) Module-by-module
display (1x) of
h
i
i
/
l
d
7
lights up: Short
circuit/overload
d
i
s
p
l
a
y
(
1
x
)
o
f
Short circuit/overload 7out: No short circuit/overload
P(red) Group display (4x) of short
circuit/overload 8lights up: Short
circuit/overload
c
i
r
c
u
i
t
/
o
v
e
r
l
o
a
d
8
out: No short circuit/overload
5 Technical specifications
Description Explanation/values
Digital inputs 16 inputs as per IEC 61131
Type 2, PNP
Electrical isolation
between channels
between CPI systems
No
No
Logic current consumption via
CPI system
max. 75 mA at 24 V
Max. capacitive loading of sensor
supply group (e.g. x1, x2)
100 F at 130 mAμ
Short circuit protection
Sensor supply
Yes, electronic
Response threshold group max. 0.18 A/group,
slow-blowing
Automatic Voltage return after
short circuit
No
protection type (plug connector
inserted or with protective cap)
IP65 as per EN 60529
Protection against electric shock
(direct and indirect contact as
per IEC/DIN EN 60204-1)
by means of a PELV circuit
Electromagnetic compatibility
EMC interference emission
EMC resistance to interference
See declaration of conformity
!www.festo.com
Vibration and shock tested as per IEC / EN 60068 part
2-6 and 2-27
Permitted ambient temperature
– Operation
– Storage
-5 … +50 °C
-20 … +70 °C
Relative air humidity 95 % at 40 °C,
non-condensing
Earthing (FE)
with hat rail
with wall mounting
with hat rail fastening by means
of terminal (fastening set
supplied)
via earthing plate with earthing
cable
CPI-modulen CP-E16-M12-EL sv...............................
1 Funktion
CPI-modulen CP-E16-M12-EL är endast avsedd för annd-
ning en CP-sträng från Festo. CPI-/CP-moduler ska endast
användas:
enligt gällande bestämmelser
i originalskick utan egna föndringar
i tekniskt felfritt skick.
CPI-modulen CP-A08-M12-EL sdjer CPI-system med utö-
kade funktioner.
2 Användning
Angivna gränsvärden för temperatur, elektrisk data, vridmo-
ment etc. ska beaktas. Utförlig information finns i manualen
typ P.BE-CPEA-CL-... (kombinerad beskrivning för CP-CL- och
CP-EL-moduler).
3 Montering och idrifttagning
Information.............................................
Innan installations- och underllsarbeten rjas ska
ljande kopplas från:
– Tryckluftsmatning
Matnings- och lastspänningsförsörjning
Fastsättning av modulen: Med integrerat reläskenste
(med bifogat monteringsset) eller väggmontage.
Skyltllarfäste 6: På integrerade insticksspår på längssi-
dan och smalsidan. Skylthållare9kan beställas med arti-
kelnummer 547473 (typ ASCF-H-E2).
r så här om du vill tta in en CPI-modul i en CP-sträng:
Montera CPI-modulen.
Anslut CP-kabeln.
Koppla till snningsrrjningen till CPI-mastern.
Utför automatisk registrering av strängschemat CPI-
mastern med knappen SAVE eller DIL-omkopplare. lj
manualen för mastern.
Starta om CPI-mastern (Power OFF/ON).
Bild 1 visar modulmåtten. Modulens höjd är ca 30 mm.
Bild 2 visar anslutningarna till modulen CP-E16-M12-EL:
Bild 2 Anslutning Kontaktkonfigu-
ration
1CPI In (M9, hankontakt, 5-polig) -
2CPI Out (M9, honkontakt, 5-polig) -
3Jordning FE
4Sensor (8x M12, honkon-
takt,5-polig) Stift 1: +24V DC
Stift 2: Ingång Ex+1
Stift 3: 0 V
Stift 4: Ingång Ex
Stift 5: FE
4 Diagnos via lysdioder (LED) 5
5
5
55
CPI-modulen CP-E16-M12-EL möjliggör gruppdiagnos och
gruppövervakning av sensorspänningen. En grupp består av
4 ingångar.
LED Drifttillstånd och felindikering
PS
(
ö
)
Indikering av CPI-kommuni-
k
(
i
Lyser: Kommunikation OK
(grön) kationsstatus (matnings-
s
p
ä
n
n
i
n
g
s
t
i
f
t
1
)
Blinkar: Underspänning
spänning, sti
f
t 1
)
Släckt: Matningsspänning
ligger inte
0 ... 15
(
ö
)
Kanalvis indikering status
i
å
(
6
)
Lyser: Signalingång
(grön) ingångarna (16x) Släckt: Ingen signalingång
P
(röd)
Modulvis indikering (1x) av
kortslutning/överbelastning
7
Lyser: Kortslutning/överbe-
lastning
(
r
ö
d
)
k
o
r
t
s
l
u
t
n
i
n
g
/
ö
v
e
r
b
e
l
a
s
t
n
i
n
g
7Släckt: Ingen kortslutning/
överbelastning
P
(röd)
Gruppvis indikering (4x) av
kortslutning/överbelastning
8
Lyser: Kortslutning/överbe-
lastning
(
r
ö
d
)
k
o
r
t
s
l
u
t
n
i
n
g
/
ö
v
e
r
b
e
l
a
s
t
n
i
n
g
8Släckt: Ingen kortslutning/
överbelastning
5 Tekniska data
Beteckning Förklaring/värden
Digitala ingångar 16 ingångar enligt IEC 61131
typ 2, PNP
Potentialisolering
mellan kanaler
mellan CPi-system
Nej
Nej
Logikströmförbrukning via CPI-system max. 75 mA vid 24 V
Max. kapacitiv belastning sensorr-
sörjning grupp (t.ex. x1, x2)
100 F vid 130 mAμ
Kortslutningsskydd
sensorförsörjning
Ja, elektroniskt
Aktiveringsgräns grupp max. 0,18 A/grupp, trög
Autom. spänningsåterställning efter
kortslutning
Nej
Kapslingsklass (anslutningskontakten
kopplad eller försedd med skydds-
plugg)
IP65 enligt EN 60529
Skydd mot elektriska stötar (direkt
och indirekt beröring enligt IEC/DIN
EN 60204-1)
genom PELV-krets
Elektromagnetisk kompatibilitet
– EMC-störningsnivå
– EMC-immunitet
se försäkran om överens-
stämmelse
!www.festo.com
Vibrationer och stötar kontrollerad enligt IEC /
EN 60068, del 2-6 och 2-27
Tillåten omgivningstemperatur
– Drift
– Förvaring
-5 … +50 °C
-20 … +70 °C
Relativ luftfuktighet 95 % vid 40 °C,
ej kondenserande
Jordning (FE)
vid reläskena
vid väggmontage
via reläskenfäste med
klämma (monteringssats
bifogas)
via jordbleck med jordkabel
Kurzbeschreibung
Brief description
Kort beskrivning
Festo SE & Co. KG
Postfach D-73726
Esslingen Phone:
+49/711/347-0
www.festo.com
746 2590904a
Original: de
CP-E16-M12-EL


Produkt Specifikationer

Mærke: Festo
Kategori: Ikke kategoriseret
Model: CP-E16-M12-EL

Har du brug for hjælp?

Hvis du har brug for hjælp til Festo CP-E16-M12-EL stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Festo Manualer

Festo

Festo HMIA-E05 Manual

13 Oktober 2024
Festo

Festo CPX-CM-HPP Manual

13 Oktober 2024
Festo

Festo CCES-P-C8-E Manual

13 Oktober 2024
Festo

Festo KSK-185 Manual

13 Oktober 2024
Festo

Festo HMIA-E10 Manual

13 Oktober 2024
Festo

Festo CDPX-EA-V2 Manual

13 Oktober 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer