Festo CPX-CEC-M1-V3 Manual

Festo Ikke kategoriseret CPX-CEC-M1-V3

Læs nedenfor 📖 manual på dansk for Festo CPX-CEC-M1-V3 (3 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 7 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/3
Control block
CPX-CEC
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
Brief description
(Translation of the original instructions)
CODESYS controller
8060496
2018-05c
[8060498]
Control block CPX-CEC English
1 Use for intended purpose
The control block is intended exclusively for use in machines or automated systems.
The control block serves as CODESYS controller for:
Controlling CPX terminals
Controlling pneumatic and electric actuators
Communication via Ethernet
The control block may only be used as follows:
As intended in industrial environments. Outside of industrial environments,
e.g. in commercial and mixed-residential areas, actions to suppress interference
may have to be taken.
In its original condition, without unauthorised modifications.
In faultless technical condition.
Only in combination with approved components.
Within the limits of the product defined through the technical data.
Take the following into consideration for the destination:
Regulations and standards
Regulations of the testing organisations and insurers
National specifications
Additional information:
In the description of the control block è Fig. 1
In the CPX system description è CPX-SYS-...
On ModbusTCP è www.modbus.org
All available documents for the product è www.festo.com/pk.
CANopen®, CODESYS®, MODBUS® are registered trademarks of
the respective trademark owners in certain countries.
This product uses open-source software which is subject to the “GNU General
Public License, Version 2”. The license terms of the GPL are available within
the programming system as well as at the following addresses:
– http://www.gnu.org/copyleft/gpl.html
Internal CPX-CEC-…-V3 web server:
http://<IP address of the device>/cgi-bin/system-about
Variants
The control block is available in the following variants:
Control block CODESYS Interface Description
CPX-CEC RS232 CPX-CEC-...V2 pbF
CPX-CEC-C1 CANopen
CPX-CEC-M1 1) CANopen + SoftMotion
CPC-CEC-S1-V3 RS232 CPX-CEC-...-V3V3 pbF
CPX-CEC-C1-V3 CANopen
CPX-CEC-M1-V3 CANopen + SoftMotion
1) Discontinued 12/2015, alternative product: CPX-CEC-M1-V3
Fig. 1 Variants of the control block
Training of qualified personnel
The product must only be commissioned by trained experts in control and automa
tion technology who are familiar with:
Mounting, installation, operation and diagnostics of control systems, networks
and fieldbus systems.
The applicable regulations for accident prevention and occupational safety.
The documentation for the product.
Service
Contact your regional Festo contact person if you have technical questions
è www.festo.com.
2 Safety
Before assembly or installation work:
Switch off the power supply.
Switch off the compressed air supply.
Exhaust any pneumatic components.
Observe the instructions for correctly mounting the CPX terminal.
For the electric power supply, use only PELV circuits that ensure a reliable elec
tric disconnection from the mains network.
Observe IEC602041/EN602041.
Observe the handling specifications for electrostatically sensitive devices.
Observe the notes on installation and power supply as well as potential equal
isation (earthing measures) in the CPX system description è CPX-SYS-...
Use connectors with the required degree of protection
è Ensuring the degree of protection.
Seal unused connections with covers to achieve the required degree of protec
tion è Ensuring the degree of protection.
Observe the specifications in the CPX system description, in the descriptions of
the valve terminal used as well as in the assembly instructions of the individual
components.
Place only a completely mounted and wired CPX terminal into operation.
Only switch on the compressed air and load voltage if the system has been pro
fessionally installed, configured and parameterised.
When performing maintenance and repair work, use suitable interlocks to pre
vent unintended movements of the actuators.
3 Connection and display components
4
1
2
3
5
6
1LED indicators
2RUN/STOP rotary switch
3Ethernet interface
4Communication interface
1)
5DIL switch
6Service interface
2)
1) For CPX-CEC-C1/M1/C1-V3/M1-V3: CANopen interface (plug, 9-pin, Sub-D),
for CPX-CEC/-S1-V3; RS232 interface (socket, 9-pin, Sub-D).
2) Socket, M12, A-coded, 5-pin; for the operator unit CPX-MMI.
Fig. 2 Connection and display components
3.1 Ethernet interface
The Ethernet interface connection of a programming unit, PC or operator unit
to the control block.
Connection Pin Signal Explanation
1 TD+ Transmitted data+
2 TD– Transmitted data-
3 RD+ Received data+
4 Not connected
5 Not connected
6 RD Received data-
7 Not connected
8 Not connected
Housing – Shield
Fig. 3 Ethernet interface, socket, 8-pin, RJ45


Produkt Specifikationer

Mærke: Festo
Kategori: Ikke kategoriseret
Model: CPX-CEC-M1-V3

Har du brug for hjælp?

Hvis du har brug for hjælp til Festo CPX-CEC-M1-V3 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Festo Manualer

Festo

Festo SAMH-F12-MK Manual

17 November 2024
Festo

Festo SFAB Manual

17 November 2024
Festo

Festo SASC-P4-A-M8-S Manual

17 November 2024
Festo

Festo SFAH Manual

17 November 2024
Festo

Festo DRRD-12 Manual

17 November 2024
Festo

Festo SDE3 Manual

17 November 2024
Festo

Festo SFTE Manual

17 November 2024
Festo

Festo CRVZS-5 Manual

17 November 2024
Festo

Festo DGC-8 Manual

17 November 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Elektron

Elektron Overbridge Manual

26 November 2024
Elektron

Elektron Sidstation Manual

26 November 2024
SoundTube

SoundTube IPD-RS82-EZ Manual

26 November 2024
Kramer

Kramer 4x1VB Manual

26 November 2024
Kramer

Kramer RC-63A Manual

26 November 2024
SoundTube

SoundTube IPD-HP82-EZ Manual

26 November 2024
Kramer

Kramer RK-KVM-1U-PP3 Manual

26 November 2024
Gioteck

Gioteck VX-2 (PS3) Manual

26 November 2024