Festo CPX-FB40 Manual


Læs nedenfor 📖 manual på dansk for Festo CPX-FB40 (2 sider) i kategorien niet gecategoriseerd. Denne guide var nyttig for 4 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Bus node
CPX-FB40
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
Brief description
Translation of the original instructions
8101660
2018-11a
[8101662]
Bus node CPX-FB40 English. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
For all available product documentation è www.festo.com/pk
1 Intended use
The module described in this document is intended for use as a participant in an
Ethernet POWERLINK network in an industrial environment. Outside of industrial
environments, e.g. in commercial and mixed-residential areas, actions to suppress
interference may have to be taken.
The module is intended exclusively for use in CPX terminals from Festo for installation
in machines or automated systems and may be used only in the following ways:
in an excellent technical status
in original status without unauthorised modifications, except for the adapta
tions described in this documentation
within the limits of the product defined through the technical data.
2 Safety
This documentation is directed exclusively at technicians trained in control and
automation technology.
You can find detailed information in the description for the module
(è P.BE-CPX-FB40-…) as well as in the CPX system description
(è P.BE-CPX-SYS-…).
Warning
Electric shock
Injury to people, damage to the machine and system
For the electrical power supply, use only PELV circuits in accordance with
IEC 60204-1 (Protective Extra-Low Voltage, PELV).
Observe the general requirements of IEC 60204-1 for PELV circuits.
Use only voltage sources which guarantee reliable electrical isolation of the
operating and load voltage in accordance with IEC 60204-1.
Always connect all circuits for operating and load voltage supplies U
EL/SEN,
UVAL and UOUT
.
Note
Electrostatically sensitive devices
Do not touch any components.
Observe the handling specifications for electrostatically sensitive
devices.
Note
Take into consideration the specifications and notes in the module description
and the assembly instructions for the components.
Commission the module only if fully mounted and wired.
Ethernet POWERLINK®, SPEEDCON® are registered trademarks of the
respective trademark owners in certain countries.
3 Electrical connections and indicators
1
2
3
4
5
1Rating plate
2Network- and CPX-specific LEDs
3Network connections X1 and X21)
4DIL switch cover
5Service interface
2) for CPX-MMI or
the adapter3) for the CPX-FMT
1) M12 socket, D-coded, 4-pin
2) M12 socket, A-coded, 5-pin
3) Adapter NEFC-M12G5-0.3-U1G5 for paramet
erisation via a USB connection
Fig. 1
3.1 Network connections
Socket Connection [X1]/[X2]
Pin Signal Explanation
M12, 4-pin
1
2
3
4
Housing
TD+
RD+
TD–
RD–
FE
Transmitted data +
Received data +
Transmitted data
Received data
Screening/FE1)
1) The screened connection is connected to the earth potential of the CPX terminal through an RC element.
Fig. 2
3.2 LED indicators - normal operating status
Behaviour of the LED indicators in normal operating status:
the green LEDs BS, PS and PL are illuminated
the green LEDs L/A1 and L/A2 are illuminated or flash if a network cable is con
nected
the yellow LED (M) is illuminated, flashes or is dark
the red LEDs (BE, SF) are not illuminated.
A network cable does not need to be connected at both network connec
tions.
Network-specific LED indicators CPX-specific LED indicators2)
BS (green) Data communication OK1) PS (green) Power system
BE (red) Data communication faulty1) PL (green) Power load
L/A1 (green) Link/activity port 1 SF (red) System failure
3)
L/A2 (green) Link/activity port 2 M (yellow) Modify4)
1) Detailed information (è description for the module P.BE-CPX-FB40-…)
2) Detailed information (è CPX system description P.BE-CPX-SYS-…)
3) Flashes in case of error, error diagnostics (è CPX system description P.BE-CPX-SYS-…)
4) Parameterisation revised or “Forceactive.
Fig. 3
4 Mounting and dismantling
Warning
Electric shock
Injury to people, damage to the machine and system
Switch supply power off before assembly work.
2
3
1
1Screws
2Module
3Interlinking block
Fig. 4


Produkt Specifikationer

Mærke: Festo
Kategori: niet gecategoriseerd
Model: CPX-FB40

Har du brug for hjælp?

Hvis du har brug for hjælp til Festo CPX-FB40 stil et spørgsmål nedenfor, og andre brugere vil svare dig




niet gecategoriseerd Festo Manualer

Festo

Festo SIES-Q8B-PS-K-L Manual

24 September 2024
Festo

Festo SIES-Q8B-PO-K-L Manual

24 September 2024
Festo

Festo SFL-6 Manual

24 September 2024
Festo

Festo DASP-V4-8-A-R1 Manual

24 September 2024
Festo

Festo CPX-FB40 Manual

24 September 2024
Festo

Festo HMVY-2 Manual

24 September 2024
Festo

Festo HMIO-AP-2 Manual

24 September 2024
Festo

Festo HMVY-3 Manual

24 September 2024
Festo

Festo HMVD-LP-DL25/40 Manual

24 September 2024
Festo

Festo HMIZB-E03 Manual

24 September 2024

niet gecategoriseerd Manualer

Nyeste niet gecategoriseerd Manualer