Festo SMAT-8M-U-E-2,5-OE Manual

Festo Ikke kategoriseret SMAT-8M-U-E-2,5-OE

Læs nedenfor 📖 manual på dansk for Festo SMAT-8M-U-E-2,5-OE (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 11 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
SMAT-8M
Position transmitter
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
Operating instruction
8203946
2023-12h
[8203948]
8203946
Translation of the original instructions
© 2024 all rights reserved to Festo SE & Co. KG
1 Applicable documents
All available documents for the product
èwww.festo.com/sp.
2 Safety
2.1 General safety instructions
Only use the product if it is in perfect technical condition.
2.2 Intended use
This product is intended for proximity sensing of the piston position of Festo
drives that can be detected magnetically. The device is intended for use in an
industrial environment.
It is suitable for use with Festo Festo drives with T-slot (profile slot8) and round
cylinders and tie-rod cylinders with mounting kitsèwww.festo.com/catalogue.
2.3 Training of qualified personnel
Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers. The qualified personnel have skills and
experience in dealing with electrical (open-loop) control technology.
2.4 UL/CSA Certification
In combination with the UL inspection mark on the product, the information in this
section must also be observed in order to comply with the certification conditions
of Underwriters Laboratories Inc. (UL) for USA and Canada.
UL/CSA certification information
Product category code NRKH, NRKH7
File number E232949
Considered standards UL 60947-1
UL 60947-5-2
CAN/CSA C22.2 No. 60947-1
CAN/CSA C22.2 No. 60947-5-2
UL mark
UL control number Industrial Control Equipment 2MD1
Tab. 1: UL/CSA certification information
Only for connection to a NEC/CEC Class 2 supply.
Locally installed conductors for the position transmitter must be separated from
the on-site and factory-installed conductors and uninsulated live parts of other
circuits that operate with more than 150V to earth. A permanent minimum
distance of 50.8mm (2inches) must be observed. If the locally installed conduc-
tors have been provided with approved insulating material that has an identical
or higher rated operating voltage than the other circuit involved, the minimum
distance need not be observed.
3 Additional information
Contact the regional Festo contact if you have technical problems
èwww.festo.com.
Accessories and spare parts èwww.festo.com/catalogue.
4 Product overview
4.1 Configuration
1
2
3
4
Fig. 1: Design of SMAT-8M
1
Retaining screw
2
Connecting cable, depending on
the version with a rotatable M8
plug or cable with open end
3
Red LED: piston not in sensing
range
4
Green LED: piston in sensing
range
4.2 Function
The position transmitter SMAT-8M is an electronic position transmitter with a 3D
Hall sensor arrangement, integrated signal processing, analogue voltage output
and optical operating status display.
The magnetic field of the piston magnet is detected, the magnetic field compo-
nents are evaluated internally and output within the sensing range as an ana-
logue displacement-proportional signal at the output. The sensing range varies
depending on the cylinder.
5 Assembly
Any mounting position can be used.
1
2
Fig. 2: Mounting
1
Internal hex key, spanner size
1.5mm
2
T-slot
1. Place the position transmitter in the T-slot of the drive.
2. Tighten the retaining screw.
Maximum tightening torque: 0.3Nm
6 Installation, electrical
WARNING
Risk of injury due to electric shock.
Use exclusively PELV circuits in accordance with IEC60204-1/EN60204-1 for
the electrical power supply (Protective Extra-Low Voltage, PELV).
Observe the general requirements of IEC60204-1/EN60204-1 for PELV cir-
cuits.
Use exclusively voltage sources that guarantee reliable electrical isolation from
mains power in accordance with IEC60204-1/EN60204-1.
1. Switch off the operating voltage.
2. Connect the connecting cable to the higher-level controller.
SMAT-8M-UE-0.3-M8D SMAT-8M-UE-2.5-OE
BN
BK
BU
RL
1
4
3
WH2
+24 V
0 V
G
U
M8x1, 4-pin, max. tightening torque: 0.3Nm
Tab. 2: Circuit diagram and pin allocation


Produkt Specifikationer

Mærke: Festo
Kategori: Ikke kategoriseret
Model: SMAT-8M-U-E-2,5-OE

Har du brug for hjælp?

Hvis du har brug for hjælp til Festo SMAT-8M-U-E-2,5-OE stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Festo Manualer

Festo

Festo SAMH-F12-MK Manual

17 November 2024
Festo

Festo SFAB Manual

17 November 2024
Festo

Festo SASC-P4-A-M8-S Manual

17 November 2024
Festo

Festo SFAH Manual

17 November 2024
Festo

Festo DRRD-12 Manual

17 November 2024
Festo

Festo SDE3 Manual

17 November 2024
Festo

Festo SFTE Manual

17 November 2024
Festo

Festo CRVZS-5 Manual

17 November 2024
Festo

Festo DGC-8 Manual

17 November 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Kramer

Kramer VP-8X8 Manual

25 November 2024
Kramer

Kramer PT-2C Manual

25 November 2024
Lazer

Lazer Bob+ Manual

25 November 2024
Dometic

Dometic DPS 80 Manual

25 November 2024
Kramer

Kramer 102MX Manual

25 November 2024
Kramer

Kramer FC-18 Manual

25 November 2024
Kramer

Kramer DSP-62-UC Manual

25 November 2024
Tiger

Tiger SKF-H101 Manual

25 November 2024