Pressure transmitter SPTE
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Deutschland
+49 711 347-0
www.festo.com
Operating instructions
Original instructions
8058488
2017-03c
[8058490]
For all available product documentation è www.festo.com/pk
1 Operating elements and connections
1
2
3
1Electrical connection
2Pneumatic connection
3Blanking plug
Fig. 1
Feature SpecificationOrder code
Function SPTE Pressure transmitter
Pressure measuring range -B2, -B11, -P025, -P05,
-P1, -P2, -P6, -P10,
-V025, -V05, -V1
èTechnical data
Pressure input R Relative pressure
Mounting/pneumatic
connection
S4 Push-in sleeve 4 mm (insertable)
S6 Push-in sleeve 6 mm (insertable)
Q3 Push-in connector 3 mm
Q4 Push-in connector 4 mm
F Flange (with through-hole and screw)
PC10 Cartridge 10 mm
Electrical output B 1 … 5 V
V 0 … 10 V
Electrical connection 2.5K 2.5 m cable, open end
Fig. 2
2 Function and application
The SPTE pressure transmitter is intended for measuring the relative pressure in
pneumatic applications. The SPTE converts pneumatic pressure values into an
electrical analogue signal, which can be used for control or regulating functions.
3 Requirements for product use
Note
Incorrect handling can lead to malfunctioning.
These general conditions for the correct and safe use of the product must be
observed at all times.
Observe the specified limits, e.g. for pressures, forces, temperatures, etc.
(è 9 “Technical data”).
Ensure that there is a supply of correctly prepared compressed air.
Please observe the prevailing ambient conditions.
Please observe the regulations applicable to the place of use (e.g. those of local
or national institutions).
Remove all transport packing such as protective wax, foils, caps, cardboard
boxes.
Remove everything used for protection during transport such as protective wax,
films, caps and cardboard boxes. The individual materials can be stored in
containers for recycling purposes.
The device is intended for industrial use. Measures may need to be implemented
in residential areas for interference suppression.
Remove dirt particles in the supply lines by blowing through the tubing and
hoses. In this way you will protect the device from premature failure or heavy
wear (è DIN ISO 4414, section 9.4).
Please observe the warnings and instructions:
on the product
in these operating instructions.
3.1 Range of application and certifications
The information in this section, in combination with the UL marking on the product,
must be observed in order for there to be compliance with the certification condi
tions of Underwriters Laboratories Inc. (UL) for USA and Canada. Observe the fol
lowing English-language remarks from UL:
For use only in or with complete equipment where the acceptability of the
combination is determined by UL LLC. When installed in an end-product,
consideration must be given to the following:
This component has been judged on the basis of the creepage and clearances
required in the indicated standards, which would cover the component itself if
submitted for listing: UL 61010-1, CAN/CSA 22.2 No. 61010-1.
The end-product shall consider that the enclosure does not serve as a
fire/electrical/mechanical enclosure, the product should be used with
enclosure at the end product.
The output connectors are not investigated for field wiring.
The unit is considered acceptable for use in a max ambient of: 50 °C/122 °F.
UL approval information
Product category code QUYX2 (USA) or
QUXY8 (Canada)
File number E322346
Considered Standards UL 61010-1
CAN/CSA 22.2 No. 61010-1
UL mark
Fig. 3
4 Installation
4.1 Mechanical and pneumatic
Note
Mount the SPTE or connect the tubing so that no condensation from the com
pressed air lines can gather in the device.
It can be fitted in any position. Mount the SPTE as follows:
SPTE-…-Q…
with mounting clip
SPTE-…-Q… SPTE-…-S… SPTE-…-F
1
1. If necessary, shorten
the SAMH-8 to the de
sired number of slots.
2. Obser ve the hole pat
tern for the SAMH
(èFig. 10).
3. Mount the SAMH with
M3 screws (included
in the scope of
delivery)1).
4. Insert the SPTE into
the SAMH mounting
clip in the direction of
the arrow. (Cable
outlet at the top or
bottom is possible).
5. Connect the tubing of
the SPTE (ènext
column).
Single-ended tubing
1. Seal a pneumatic
connection on the
SPTE with the
blanking plug 1.
2. Connect the tube
to the free pneu
matic connection.
Double-sided tubing
1. Remove the
blanking plug 1.
2. Connect the tube
to both pneu
matic connec
tions.
1. Insert the
pneumatic
connection of the
SPTE into the
push-in fitting as
far as possible.
1. Observe the hole
pattern for the
flange (èFig. 10).
2. Check the correct
seating of the
sealing ring.
3. Secure the SPTE in
place using two M2
screws (included in
the scope of
delivery)2).
1) Tightening torque: max. 0.6 Nm
2) Tightening torque: max. 0.3 Nm
Fig. 4


Produkt Specifikationer

Mærke: Festo
Kategori: Ikke kategoriseret
Model: SPTE-P10R-S6-B-2.5K

Har du brug for hjælp?

Hvis du har brug for hjælp til Festo SPTE-P10R-S6-B-2.5K stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Festo Manualer

Festo

Festo SAMH-F12-MK Manual

17 November 2024
Festo

Festo SFAB Manual

17 November 2024
Festo

Festo SASC-P4-A-M8-S Manual

17 November 2024
Festo

Festo SFAH Manual

17 November 2024
Festo

Festo DRRD-12 Manual

17 November 2024
Festo

Festo SDE3 Manual

17 November 2024
Festo

Festo SFTE Manual

17 November 2024
Festo

Festo CRVZS-5 Manual

17 November 2024
Festo

Festo DGC-8 Manual

17 November 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Kramer

Kramer VP-8X8 Manual

25 November 2024
Kramer

Kramer PT-2C Manual

25 November 2024
Lazer

Lazer Bob+ Manual

25 November 2024
Dometic

Dometic DPS 80 Manual

25 November 2024
Kramer

Kramer 102MX Manual

25 November 2024
Kramer

Kramer FC-18 Manual

25 November 2024
Kramer

Kramer DSP-62-UC Manual

25 November 2024
Tiger

Tiger SKF-H101 Manual

25 November 2024