Fito ASD-10 Manual
Fito
Røgdetektor
ASD-10
Læs nedenfor 📖 manual på dansk for Fito ASD-10 (2 sider) i kategorien Røgdetektor. Denne guide var nyttig for 10 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/2
IMPORTANT INFORMATION
Correct usage will ensure you have valuable extra time to
escape. Every correctly installed smoke detector will
increase your potential escape time.
• measure.A smoke detector is not a fire-prevention
• pos-sible Install the smoke detector in the correct place, if
in the middle of the ceiling.
• children.Keep the smoke detector out of the reach of
• period of Test the unit on a weekly basis and after any
absence.
CAUTION: Never test with fire!
• Clean the detector regularly (once a month) using the soft
brush from a vacuum cleaner. The smoke alarm can also
be cleaned using a moist cloth.
• If the detector emits a beeping sound every 40 seconds,
this means that the battery is nearly flat and that you should
replace the smoke detector.
• years.The lifespan of smoke detectors is 10
• and A false alarm can be silenced by pressing the test
silence button.
• You can make your Model ASD-10 smoke detector less
sensitive for 8-9 minutes by pressing the test but-ton. The
detector will nonetheless sound the alarm if the quantity of
smoke is too significant.
• Plan TWO escape routes and rehearse these with all
members of the family.
• BUILDINGIN THE EVENT OF A FIRE: LEAVE THE
IMMEDIATELY TAKING ALL FAMILY MEMBERS
WITH YOU, GATHER OUTSIDE AT A PRE-AGREED
MUSTER POINT AND CHECK THAT EVERYONE IS
PRESENT AND ACCOUNTED FOR.
CLOSE ALL AND DOORS BEHIND YOU NEVER
OPEN A WARM DOOR. IF A DOOR IS WARM,
CHOOSE AN ALTERNATIVE THE ROUTE. CALL FIRE
BRIGADE OUTSIDE AT A FROM OR NEIGHBOUR’S
HOUSE. NEVER GO BACK INTO A BURNING
BUILDING.
• In the event of considerable build-up of smoke, crawl out of
the building keeping as close to the floor as possible.
Wherever possible, breathe through a cloth (preferably
moist), or else hold your breath as much as you can. The
majority of deaths and injuries are caused by smoke
inhalation rather than fire itself.
SPECIFICATIONS
Power: Battery3VDC Lithium AA
Battery 10 years under life: normal
conditions
Usage: < 10 µA continuous
< 60 mA in alarm
Usage temperature: 0ºC to + 55ºC
± 3% at 93% RH at 40ºCHumidity:
Sensitivity:
Alarm volume:
Certification:
In accordance with EN14604
>85dB at 3 metres
ANPI EN14604, CE-13, BOSEC
POSITIONING THE SMOKE DETECTOR
Minimum protection:
In all rooms, such as bedrooms, living room, study and
suchlike, as well as along escape routes such as corridor
or hallway.
Maximum protection:
- Smoke detector in all rooms (with the exception of
bathrooms, kitchen, garages, etc.)
- Heat detectors can be installed in bathrooms, kit-
chens, airing cupboards, utility rooms, etc. within 5
metres of a potential source of fire.
Recommended
locations:
• smokeThe
detector should
preferably be
installed in the
middle of the
ceiling, at least
50 cm from the
wall.
• ofIn the case
pitched roofs,
install the detec-
landing
tor on the slo-
ping wall, at
least 90 cm (measured vertically) from the ridge of
the roof.
• See minimum and maximum protection (figures 1 & 2)
• Ensure that the detector can always be reached
for testing and cleaning.
Never fit a smoke detector:
• In bathrooms, kitchens, shower rooms, garages, etc.
Places where a smoke detector may go off needles-
sly due to condensation, normal smoke or gases. A
smoke detector should be fitted at least 5 metres from
such sources of smoke.
• 50° Places where the temperature may exceed C
or fall 0° below C, e.g. attics, just above a fireplace,
•In the vicinity of (or adjacent etc. to) decorative objects,
doors, sockets, lights, fittings, windows, wall venti-
lators, etc. which could mean that smoke does not
reach the smoke detector. Minimum 50cm away.
• Surfaces that are usually warmer or colder than the
rest of the room. Differences in temperature can pre-
vent smoke from reaching the detector.
• heaters.Adjacent to or directly above stoves or
figure 4
LED-light
test-/pause button
figure 1
kitchen
living room
bath-
room
bedroom
bedroom
bedroom
hallway
bedroom
bedroom
bedroom hallway
kitchen living
room
figure 2
hallway
Instruction manual
10-YEAR OPTICAL SMOKE DETECTOR WITH BUILT-IN 10-YEAR 3V BATTERY
1134
EN14604:2005/AC 2008
Essential characteristics: Performance:
Nominal activation conditions/sensitivity,
response delay (response time) and
performance under fire conditions:
Passed
Fito Products BV
Molenvliet 22
3961 MV
Wijk bij Duurstede
The Netherlands
13
1134-CPR-122
Operational reliability: Passed
Tolerance to supply voltage: Passed
Durability of operational reliability and
response delay, temperature resistance:
Passed
Durability of operational reliability,
vibration resistance:
Passed
Optical smoke
detector, alerts you in
the event of fire or
smoke, and is suitable
for esidential r
buildings.
Durability of operational reliability,
humidity resistance:
Passed
Durability of operational reliability,
corrosion resistance:
Passed
Durability of operational reliability,
electrical stability:
Passed
FD
9178
RETAIN THESE INSTRUCTIONS FOR USE!
These instructions for use contain important information for correct installation and
use of your smoke detector. Please read this information carefully and retain these
instructions for reference.
Model: ASD-10
• it hard In very high or difficult to reach places. This makes
to reach the detector to test or clean it.
• In very dusty or dirty places. Accumulation of dust will
prevent smoke from reaching the smoke chamber and in
time will lead to a false alarm.
• Some Within 1 metre of dimmer switches and wiring.
dimmer switches can trigger a fault in the detector.
• Within 1.5 metres of fluorescent lights. Electrical impulses
can adversely affect the functioning of the detector.
• Outdoors and in spaces where a large number of insects
are found. Small insects in the unit’s detection chamber can
disrupt the functioning of the detector.
The underside of the detector gives important
information.
ATTENTION: The smoke alarm should be temporarily
removed during renovation work or structural alterati-ons.
Clean the smoke detector with the soft brush from a vacuum
cleaner once the day’s work is complete, and then replace
the detector, always testing it by pressing the test button
once it has been reinstalled.
INSTALLATION
1. Choose location a that
satisfies the conditions as
described in: Positioning
the smoke detector .
2. Remove the base plate
of the detector (figure
3) baseby turning the
plate anticlockwise (to
the left).
3. mounting Mark the
figure 3
holes in the base plate
and drill the holes (use a 6 mm drill). If not using the
screw plugs, then use a 3 mm drill. Screw the base
plate securely onto the ceiling. Make sure that the base
plate is tight against the ceiling so that no air circulation
above the smoke alarm is possible, which could impede
smoke detection. If the opening is too large, this should
be remedied using the kit.
4. Place the smoke detector on the base plate and turn it until
the smoke detector clicks into the base plate. Turn the
smoke detector clockwise (to the right from the OFF to the
ON stripe) to secure the smoke detector and activate it. (See
figure 4)
Mounting holes
Produkt Specifikationer
Mærke: | Fito |
Kategori: | Røgdetektor |
Model: | ASD-10 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Fito ASD-10 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Røgdetektor Fito Manualer
16 September 2024
13 September 2024
23 August 2024
21 August 2024
21 August 2024
21 August 2024
20 August 2024
18 August 2024
17 August 2024
31 Juli 2024
Røgdetektor Manualer
- Røgdetektor Ikea
- Røgdetektor Hager
- Røgdetektor Ei Electronics
- Røgdetektor Gigaset
- Røgdetektor Emos
- Røgdetektor TFA
- Røgdetektor Nedis
- Røgdetektor Abus
- Røgdetektor Clas Ohlson
- Røgdetektor Smartwares
- Røgdetektor Trust
- Røgdetektor Blaupunkt
- Røgdetektor Bavaria
- Røgdetektor Vivanco
- Røgdetektor König
- Røgdetektor FireAngel
- Røgdetektor Elro
- Røgdetektor Mercury
- Røgdetektor Malmbergs
- Røgdetektor Alecto
- Røgdetektor Flamingo
- Røgdetektor Olympia
- Røgdetektor B/R/K
- Røgdetektor GEV
- Røgdetektor JUNG
- Røgdetektor ORNO
- Røgdetektor Netatmo
- Røgdetektor M-e
- Røgdetektor Somfy
- Røgdetektor EQ3
- Røgdetektor Brennenstuhl
- Røgdetektor Elgato
- Røgdetektor EVE
- Røgdetektor Pentatech
- Røgdetektor Eminent
- Røgdetektor GLORIA
- Røgdetektor Fibaro
- Røgdetektor X-Sense
- Røgdetektor EQ-3
- Røgdetektor Dahua Technology
- Røgdetektor Chacon
- Røgdetektor Stabo
- Røgdetektor First Alert
- Røgdetektor Nexa
- Røgdetektor Kogan
- Røgdetektor Esylux
- Røgdetektor Homematic IP
- Røgdetektor H-Tronic
- Røgdetektor Kidde
- Røgdetektor Schwaiger
- Røgdetektor Inovonics
- Røgdetektor Ajax
- Røgdetektor AngelEye
- Røgdetektor KlikaanKlikuit
- Røgdetektor Marquant
- Røgdetektor Gira
- Røgdetektor FireX
- Røgdetektor Interlogix
- Røgdetektor DSC
- Røgdetektor FirstAlert
- Røgdetektor Satel
- Røgdetektor FireHawk
- Røgdetektor Chuango
- Røgdetektor ETiger
- Røgdetektor TEF
- Røgdetektor SAVS
- Røgdetektor Jalo Helsinki
- Røgdetektor Fito Profi-line
- Røgdetektor System Sensor
- Røgdetektor Pristine
- Røgdetektor Cavius
- Røgdetektor Jemay
- Røgdetektor Mircom
- Røgdetektor WisuAlarm
- Røgdetektor BRK DICON
- Røgdetektor STI
- Røgdetektor Cordes
- Røgdetektor Deltronic
- Røgdetektor Insafe
- Røgdetektor Gewiss
- Røgdetektor Egardia
- Røgdetektor Qolsys
Nyeste Røgdetektor Manualer
14 Oktober 2024
8 Oktober 2024
8 Oktober 2024
3 Oktober 2024
2 Oktober 2024
2 Oktober 2024
1 Oktober 2024
1 Oktober 2024
30 September 2024
29 September 2024