Fluke 1LAC II Manual


Læs nedenfor 📖 manual på dansk for Fluke 1LAC II (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 27 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
PN 3497693
July 2009 Rev. 1, 8/20
© 2009-2020 Fluke Corporation. rights reserved. All
Specifications are subject to change without notice.
1AC II
VoltAlert
Instruction Sheet
Read First: Safety Information
 Warning
To prevent possible electric shock or personal injury:
Read all safety information before you use the Product.
Do not rely on the Tester to detect the presence or absence of voltage on a
conductor for safety purposes. A single pole non-contact voltage detector such as
this Tester is NOT suitable to determine if a circuit is hazardous. A volt meter or
2-pole voltage detector is necessary to confirm the absence of hazardous voltage
prior to commencing work
Hold the Product behind the tactile barrier.
Do not use the Product around explosive gas, vapor, or in damp or wet
environments.
Replace all alkaline batteries with fresh batteries of the same manufacturer and type
to prevent battery leakage.
Remove the alkaline batteries if the Product is not used for an extended period of
time, or if stored in temperatures above 50 °C. If the batteries are not removed,
battery leakage may result.
Repair the Product before use if the battery leaks. Battery leakage may create a
shock hazard or damage the Product.
Alkaline batteries contain hazardous chemicals that can cause burns. If exposure to
chemicals occurs, clean with water and get medical aid.
If the Tester is used in a manner not specified by the manufacturer, protection
provided by the Tester may be affected.
Do not use if VoltBeat is not flashing.
Test on a known live source within the rated ac voltage range of the product, both
before and after use to ensure unit is in good working condition.
When using the Tester, if tip does not glow, voltage could still be present. The Tester
indicates active voltage in the presence of AC electric fields of sufficient strength
emanating from the conductor. If the field strength is low, the Tester may not provide
indication of live voltages. Lack of an indication occurs if the Tester is unable to
sense the presence of electric field which may be influenced by several factors the
including, but not limited to:
Shielded wire/cables
Thickness and type of insulation
Distance from the voltage source
Fully-isolated users that prevent an effective ground
Receptacles in recessed sockets/ differences in socket design
Condition of the Tester and Batteries
Do not use if the Tester appears damaged or if the Tester is not operating properly.
Specifically examine the probe tip for cracks or breakage before use. If in doubt,
have the Tester serviced.
Do not apply more than the rated voltage as marked on the Tester.
Use caution with voltages above 30 V ac as a shock hazard may exist.
Comply with local and national safety codes. Use personal protective equipment
(approved rubber gloves, face protection, and flame-resistant clothes) to prevent
shock and arc blast injury where hazardous live conductors are exposed.
Safety: IEC 61010-1: Pollution Degree 2; IEC 61010-2-030: CAT IV 1000 V
Electromagnetic Environment: IEC 61326-1: Portable Electromagnetic Environment;
CISPR 11: Group 1, Class B
Electromagnetic Compatibility: Applies to use in Korea only. Class A Equipment (Industrial
Broadcasting & Communication Equipment)
[1]
[1] This product meets requirements for industrial (Class A) electromagnetic wave equipment
and the seller or user should take notice of it. This equipment is intended for use in business
environments and is not to be used in homes.
Voltage Detection Range:
Model
Region
Range
A1/A2
N. America, S. America, Asia
90 V ac to 1000 V ac
E1/E2
Europe
200 V ac to 1000 V ac
L (low voltage) AC
N. America
20 V ac to 90 Vac
C
China
90 V ac to 1000 V ac
FOR USE BY COMPETENT
PERSONS
Anyone using this instrument should be
knowledgeable and trained about the risks
involved with measuring voltage, especially
in an industrial setting, and the importance of
taking safety precautions and of testing the
instrument before and after using it to ensure
that it is in good working condition.


Produkt Specifikationer

Mærke: Fluke
Kategori: Ikke kategoriseret
Model: 1LAC II

Har du brug for hjælp?

Hvis du har brug for hjælp til Fluke 1LAC II stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Fluke Manualer

Fluke

Fluke 438-II Manual

8 Oktober 2024
Fluke

Fluke 1670 Manual

8 Oktober 2024
Fluke

Fluke ii905 Manual

8 Oktober 2024
Fluke

Fluke ii915 Manual

8 Oktober 2024
Fluke

Fluke ii500 Manual

7 Oktober 2024
Fluke

Fluke T5-1000 Manual

4 Oktober 2024
Fluke

Fluke 700HTH Manual

29 September 2024
Fluke

Fluke 6200-2 Manual

22 September 2024
Fluke

Fluke Ti27 Manual

22 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Atlona

Atlona AT-DVIF30S-IR Manual

29 December 2024
Atlona

Atlona AT-PRO3HD66M Manual

29 December 2024
Atlona

Atlona AT-3GSDI500 Manual

29 December 2024
BlueBuilt

BlueBuilt BBMAG2M Manual

29 December 2024
Atlona

Atlona AT-3GSDI-14 Manual

28 December 2024
Atlona

Atlona AT-COMP10SS Manual

28 December 2024
Atlona

Atlona AT-2VGA300SL Manual

28 December 2024
Atlona

Atlona AT-HD-V216 Manual

28 December 2024
Atlona

Atlona AT-VGA11S Manual

28 December 2024
True

True TC900 Manual

28 December 2024