Fluke PM8907 Manual


Læs nedenfor 📖 manual på dansk for Fluke PM8907 (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 8 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/2
Fluke Corporation Fluke Industrial B.V.
P.O. Box 9090 P.O. Box 90
Everett 7600 AB Almelo
WA 98206-9090 The Netherlands
USA
LIMITED WARRANTY & LIMITATION OF
LIABILITY
Each Fluke product is warranted to be free from
defects in material and workmanship under normal
use and service. The warranty period is one year
and begins on the date of shipment. Parts, product
repairs and services are warranted for 90 days. This
warranty extends only to the original buyer or end-
user customer of a Fluke authorized reseller, and
does not apply to fuses, disposable batteries or to
any product which, in Fluke's opinion, has been
misused, altered, neglected or damaged by accident
or abnormal conditions of operation or handling.
Fluke warrants that software will operate
substantially in accordance with its functional
specifications for 90 days and that it has been
properly recorded on non-defective media. Fluke
does not warrant that software will be error free or
operate without interruption.
Fluke authorized resellers shall extend this warranty
on new and unused products to end-user customers
only but have no authority to extend a greater or
different warranty on behalf of Fluke. Warranty support
is available if product is purchased through a Fluke
authorized sales outlet or Buyer has paid the
applicable international price. Fluke reserves the right
to invoice Buyer for importation costs of
repair/replacement parts when product purchased in
one country is submitted for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option,
to refund of the purchase price, free of charge repair,
or replacement of a defective product which is
returned to a Fluke authorized service center within
the warranty period.
To obtain warranty service, contact your nearest Fluke
authorized service center or send the product, with a
description of the difficulty, postage and insurance
prepaid (FOB Destination), to the nearest Fluke
authorized service center. Fluke assumes no risk for
damage in transit. Following warranty repair, the
product will be returned to Buyer, transportation
prepaid (FOB Destination). If Fluke determines that the
failure was caused by misuse, alteration, accident or
abnormal condition of operation or handling, Fluke will
provide an estimate of repair costs and obtain
authorization before commencing the work. Following
repair, the product will be returned to the Buyer
transportation prepaid and the Buyer will be billed for
the repair and return transportation charges (FOB
Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND
EXCLUSIVE REMEDY AND IS IN LIEU OF ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. FLUKE SHALL
NOT BE LIABLE FOR ANY SPECIAL, INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR
LOSSES, INCLUDING LOSS OF DATA, WHETHER
ARISING FROM BREACH OF WARRANTY OR
BASED ON CONTRACT, TORT, RELIANCE OR ANY
OTHER THEORY.
Since some countries or states do not allow limitation
of the term of an implied warranty, or exclusion or
limitation of incidental or consequential damages, the
limitations and exclusions of this warranty may not
apply to every buyer. If any provision of this Warranty
is held invalid or unenforceable by a court of
competent jurisdiction, such holding will not affect the
validity or enforceability of any other provision.
®
PM8907
Power Adapter/
Battery Charger
Instruction Sheet
SPECIFICATIONS
z Versions:
PM8907/801 Universal European line
plug 230V ±10%.
PM8907/804 United Kingdom line
plug 240V ±10%.
PM8907/806 Japanese line plug
100V ±10%.
PM8907/807 Australian line plug
240V ±10%.
PM8907/808 Universal switchable
adapter 115V ±10% or 230V ±15%
with plug EN60320-2.2G.
PM8907/813 North American line
plug 120V ±10%.
z Line frequency: 50, 60, and 400 Hz
±10%.
z Output voltage: 15V.
z Output current: 300 mA.
z Power consumption: 7W maximum.
z Output plug: 5-mm power jack per
DIN 45232.
z Plus (+) voltage connected to outer
contact of the 5-mm power jack.
z Operating temperature: 0 to +40 °C
(32 °F to 104 °F).
Sep 1996, Rev.4 8/08
© 1996-2008 Fluke Corporation. All rights reserved.
Printed in The Netherlands.
All product names are trademarks of their respective
companies.


Produkt Specifikationer

Mærke: Fluke
Kategori: Ikke kategoriseret
Model: PM8907

Har du brug for hjælp?

Hvis du har brug for hjælp til Fluke PM8907 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Fluke Manualer

Fluke

Fluke 438-II Manual

8 Oktober 2024
Fluke

Fluke 1670 Manual

8 Oktober 2024
Fluke

Fluke ii905 Manual

8 Oktober 2024
Fluke

Fluke ii915 Manual

8 Oktober 2024
Fluke

Fluke ii500 Manual

7 Oktober 2024
Fluke

Fluke T5-1000 Manual

4 Oktober 2024
Fluke

Fluke 700HTH Manual

29 September 2024
Fluke

Fluke 6200-2 Manual

22 September 2024
Fluke

Fluke Ti27 Manual

22 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Atlona

Atlona AT-DVIF30S-IR Manual

29 December 2024
Atlona

Atlona AT-PRO3HD66M Manual

29 December 2024
Atlona

Atlona AT-3GSDI500 Manual

29 December 2024
BlueBuilt

BlueBuilt BBMAG2M Manual

29 December 2024
Atlona

Atlona AT-3GSDI-14 Manual

28 December 2024
Atlona

Atlona AT-COMP10SS Manual

28 December 2024
Atlona

Atlona AT-2VGA300SL Manual

28 December 2024
Atlona

Atlona AT-HD-V216 Manual

28 December 2024
Atlona

Atlona AT-VGA11S Manual

28 December 2024
True

True TC900 Manual

28 December 2024