Fluke T110 Manual


Læs nedenfor 📖 manual på dansk for Fluke T110 (4 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 44 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/4
T90/T110/T130/T150
Voltage/Continuity Tester
Instruction Sheet
Introduction
The Fluke T90/T110/T130/T150 Electrical Testers (the
Tester or Product) are voltage and continuity testers
with a rotary eld indication (T110/T130/T150 only).
Their primary use is for test and measurement in
industrial, commercial, and household environments.
This Product complies with the most recent safety
standards for safe, reliable test and measurement.
The xed test probe cover prevents the risk of injury
when you move the instrument.
How to Contact Fluke
Fluke Corporation operates worldwide. For local
contact information, go to our website: www.uke.com
To register your product, view, print, or download
the latest manual or manual supplement, go to our
website.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
+1-425-446-5500
uke-info@uke.com
Safety Information
 Warning
To prevent possible electrical shock, re, or
personal injury:
Read all safety Information before you use the
Product.
Use the Product only as specied, or the
protection supplied by the Product can be
compromised.
Measure a known voltage rst to make sure
that the Product operates correctly.
Do not apply more than the rated voltage,
between the terminals or between each
terminal and earth ground.
PN 3928132
October 2011, Rev. 3, 3/21
© 2011-2021 Fluke Corporation. All rights reserved.
Specications are subject to change without notice. All product
names are trademarks of their respective companies.
Limit operation to the specied measurement
category or voltage ratings.
Do not work alone.
Comply with local and national safety codes.
Use personal protective equipment (approved
rubber gloves, face protection, and ame-
resistant clothes) to prevent shock and arc
blast injury where hazardous live conductors
are exposed.
Do not use the Product around explosive gas,
vapor, or in damp or wet environments.
Do not use and disable the Product if it is
damaged.
Do not use the Product if it operates
incorrectly.
Keep ngers behind the nger guards on the
probes.
Do not use the Product if the test leads are
damaged.
Examine the case before you use the Product.
Look for cracks or missing plastic.
The battery door must be closed and fastened
before you operate the Product.
Replace the batteries when the low battery
indicator shows to prevent incorrect
measurements.
Repair the Product before use if the battery
leaks.
For use by competent persons. Anyone
using this Product should be knowledgeable
and trained about the risks involved with
measuring voltage, especially in an industrial
setting, and the importance of taking safety
precautions and of testing the Product before
and after using it to ensure that it is in good
working condition.
Symbols
These symbols are on the Tester or in this instruction
sheet.
Symbol Explanation
Important information. Consult the
instruction sheet.
Hazardous Voltage.
Suitable for live working.
Conforms to European Union Directives
CAT III Measurement Category III is applicable to
test and measuring circuits connected to
the distribution part of the building’s low-
voltage MAINS installation.
CAT IV Measurement Category IV is applicable
to test and measuring circuits connected
at the source of the building’s low-voltage
MAINS installation.
Symbol Explanation
This product complies with the WEEE
Directive (2002/96/EC) marking
requirements. The a󰀩xed label indicates
that you must not discard this electrical/
electronic product in domestic household
waste. Product Category: With reference
to the equipment types in the WEEE
Directive Annex I, this product is classed
as category 9 "Monitoring and Control
Instrumentation" product. Do not dispose
of this producat as unsorted municipal
wast. To to Fluke's website for recycling
information.
Accessories
The Tester is supplied with accessories.
Part Number Accessory
4083642 GS38 Probe Tip Sheath
4083656 4.2 mm Probe Extensions
4111533 H15 Belt Holster (sold separately)
4111540 C150 Zippered Soft Carrying Case
(sold separately)
Figure 1 shows the Probe Tip Protector Cap. This
multifunctional accessory is useful for tests and
storage of di󰀨erent accessories. (The Probe
Extensions are stored in the Probe Tip Protector Cap
before shipment.)
Storage area for Probe Tip Sheaths
Storage area for 4.2 mm Probe Extensions
Earth-pin safety-socket opener for UK
sockets (press opener into socket to release
safety covers, see Figure 2)
Storage area for probes when not in use
2
1
4
3
1
2
Quick Reference
Use the pushbuttons to turn the functions on or o󰀨.
See the list that follows for a quick reference to each
of these pushbuttons.
Pushbutton Description
c
Push to turn torch light on or o󰀨
(T110, T130, T150).
To save battery power the
function automatically turns o󰀨
after 30 seconds.
I
Push to hold the value that shows
in the LCD in volt and resistance
measurements. Push again to
turn HOLD o󰀨 (T130, T150).
To save battery power the
function automatically turns o󰀨
after 30 seconds.
h
Push this button on each of
the probes at the same time to
start the test for low impedance
switchable load.
cp
Push and hold for 2 seconds to
turn the beeper on or o󰀨. The
status shows on the LCD (T150,
T130) or with the LED (T110).
Il
Push and hold for 2 seconds to
turn the resistance measurement
on or o󰀨 (T150 only).
To save battery power, the
function automatically turns o󰀨
after 30 seconds.
Figure 3 illustrates how to store and retrieve the tip
accessories from the cap.
3
1
4
2
5
1/4
3
6
For storage, push Probe Tip Sheath into
place.
To retrieve, rmly push probe tip into Probe
Tip Sheath.
Pull on probe handle to remove Probe Tip
Sheath.
For storage, push 4.2 mm Probe
Extensions into place.
To retrieve, rmly push probe tip into Probe
Extensions. Twist 1/4 turn.
Pull on probe handle to remove Probe
Extensions. Continue to twist until tip is tight.


Produkt Specifikationer

Mærke: Fluke
Kategori: Ikke kategoriseret
Model: T110
Bredde: 70 mm
Dybde: 38 mm
Højde: 260 mm
Vægt: 280 g
Batteritype: AAA
Antal understøttede batterier: 2
Maksimal spænding: - V
Husets farve: Black, Grey, Red, Yellow
DC spændingsområde: - V
AC-spæningsområde: - V
AC strømområde: - A

Har du brug for hjælp?

Hvis du har brug for hjælp til Fluke T110 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Fluke Manualer

Fluke

Fluke 438-II Manual

8 Oktober 2024
Fluke

Fluke 1670 Manual

8 Oktober 2024
Fluke

Fluke ii905 Manual

8 Oktober 2024
Fluke

Fluke ii915 Manual

8 Oktober 2024
Fluke

Fluke ii500 Manual

7 Oktober 2024
Fluke

Fluke T5-1000 Manual

4 Oktober 2024
Fluke

Fluke 700HTH Manual

29 September 2024
Fluke

Fluke 6200-2 Manual

22 September 2024
Fluke

Fluke Ti27 Manual

22 September 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

AOpen

AOpen DEX5950 Manual

26 November 2024
AOpen

AOpen WB5102 Manual

26 November 2024
AOpen

AOpen DE6100 Manual

26 November 2024
AOpen

AOpen DE5900 Manual

26 November 2024
AOpen

AOpen DE7000 Manual

26 November 2024
AOpen

AOpen DE7600 Manual

26 November 2024
AOpen

AOpen DES3200 Manual

26 November 2024
AOpen

AOpen DEN5128 Manual

26 November 2024
AOpen

AOpen DES4100 Manual

26 November 2024
AOpen

AOpen DEV7610 Manual

26 November 2024