Frigidaire FFRE063WAE Manual
Frigidaire
Aircondition
FFRE063WAE
Læs nedenfor 📖 manual på dansk for Frigidaire FFRE063WAE (20 sider) i kategorien Aircondition. Denne guide var nyttig for 39 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/20

Frigidaire.com USA 1-800-944-9044 Frigidaire.ca Canada 1-800-265-8352
use &care
Room Air Conditioner
16120300A25472 (July 2019)
Introduction...................................................... 2
Important Safety Instructions.................... 3
Packaging.......................................................... 7
Normal Sounds................................................ 7
Air Conditioner Features............................. 8
Care And Cleaning....................................... 15
Energy Saving Ideas................................... 15
Before You Call............................................. 16
Major Appliance Limited Warranty....... 18
Operating Instructions................................ 9

2INTRODUCTION
Welcome to our family
Model Number
Serial Number
Purchase Date
Thank you for bringing Frigidaire into your
home! We see your purchase as the
beginning of a long relationship together.
This manual is your resource for the use and
care of your product. Please read it before
using your appliance. Keep it handy for
quick reference. If something doesn’t seem
right, the troubleshooting section will help
you with common issues.
FAQs, helpful tips and videos, cleaning
products, and kitchen and home accessories
are available at www.frigidaire.com.
We are here for you! Visit our website, chat
with an agent, or call us if you need help. We
may be able to help you avoid a service visit.
If you do need service, we can get that
started for you.
Let’s make it ocial! Be sure to register your
product.
Keep your product info here so it’s easy to
find.

3
For Your Safety
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance. Read product
labels for flammability and other warnings.
Prevent Accidents
WARNING
To reduce the risk of fire, electrical shock, or
injury to persons when using your air
conditioner, follow basic precautions,
including the following:
• Be sure the electrical service is adequate
for the model you have chosen. This
information can be found on the serial
plate, which is located on the side of the
cabinet and behind the grille.
• If the air conditioner is to be installed in a
window, you will probably want to clean
both sides of the glass first. If the window
is a triple-track type with a screen panel
included, remove the screen completely
before installation.
• Be sure the air conditioner has been
securely and correctly installed according
to the separate installation instructions
provided with this manual. Save this
manual and the installation instructions for
possible future use in removing or
reinstalling this unit.
• When handling the air conditioner, be
careful to avoid cuts from sharp metal fins
on front and rear coils.
WARNING
Avoid fire hazard or electric shock. Do not
use an extension cord or an adaptor plug.
Do not remove any prong from the power
cord.
Electrical Information
WARNING
The complete electrical rating of your new
room air conditioner is stated on the serial
plate. Refer to the rating when checking the
electrical requirements.
• Be sure the air conditioner is properly
grounded. To minimize shock and fire
hazards, proper grounding is important.
The power cord is equipped with a
three-prong grounding plug for protection
against shock hazards.
• Your air conditioner must be used in a
properly grounded wall receptacle. If the
wall receptacle you intend to use is not
adequately grounded or protected by a
time delay fuse or circuit breaker, have a
qualified electrician install the proper
receptacle.
• Do not run air conditioner without outside
protective cover in place. This could result
in mechanical damage within the air
conditioner.
• Do not use an extension cord or an
adapter plug.
Grounding type wall receptacle
Do not, under any
circumstances, cut,
remove, or bypass the
grounding prong.
Power supply cord
with 3-prong grounding
plug and current
detection device

4IMPORTANT SAFETY INSTRUCTIONS
NOTE
The power supply cord with this air
conditioner contains a current detection
device designed to reduce the risk of fire.
Please refer to the section ‘Operation of
Current Device’ for details.
In the event that the power supply cord is
damaged, it cannot be repaired. It must be
replaced with a cord from the product
manufacturer.
SAFETY PRECAUTIONS
DANGER! Avoid Serious Injury or Death
• This air conditioner contains no
user-serviceable parts. Always call an
authorized Electrolux servicer for repairs.
• Do not insert or place fingers or objects
into the air discharge area in the front of
the unit.
• Do not start or stop the air conditioner by
unplugging the power cord or turning o
the power at the electrical box.
• Do not cut or damage the power cord.
• If the power cord is damaged, it should
only be replaced by an authorized
Electrolux servicer.
• In the event of a malfunction (sparks,
burning smell, etc.), immediately stop the
operation, disconnect the power cord, and
call an authorized Electrolux servicer.
• Do not operate the air conditioner with
wet hands.
• Do not pull on the power cord.
• Do not drink any water that is drained
from the air conditioner.
SAFETY PRECAUTIONS
CAUTION! Avoid Injury or damage to the
unit or other property
• Provide ventilation per installation
instructions.
• Do not direct airflow at fireplaces or other
heat related sources as this could cause
flare ups or make units run excessively.
• Do not climb on or place objects on
outdoor part of the unit.
• Do not hang objects off the unit.
• Do not place containers with liquids on
the unit.
• Turn off the air conditioner at the power
source when it will not be used for an
extended period of time.
• Periodically check the condition of the
unit’s installation accessories for any
damage.
• Do not apply heavy pressure to the
radiator fins of the unit.
• Operate the unit with air filter in place.
• Do not block or cover the intake grille,
discharge area and outlet ports.
• Ensure that any electrical/electronic
equipment is one yard away from the unit.
• Do not use or store flammable gases near
the unit.
• Do not touch the metal parts of the unit
when removing the filter. Injuries can
occur when handling sharp metal edges.
• Do not use water to clean inside the air
conditioner. Exposure to water can
destroy the insulation, leading to possible
electric shock.
• When cleaning the unit, first make sure
that the power and circuit breaker are
turned off.
WARNING
FOR FLAMMABLE REFRIGERANT
• Do not use means to accelerate the
defrosting process or to clean, other than
those recommended by the manufacturer.
• Do not pierce or burn.
• Be aware that the refrigerants may not
contain an odour.
• Compliance with national gas regulations
shall be observed.
• Keep ventilation openings clear of
obstruction.

5IMPORTANT SAFETY INSTRUCTIONS
• The appliance shall be stored in a room
without continuously operating ignition
sources (for example: open flames, an
operating gas appliance) and ignition
sourcesor (for example:an operating
electric heater) close to the appliance. The
appliance shall be stored in a room
without continuously operating ignition
sources (for example: open flames, an
operating gas appliance or an operating
electric heater).
• The appliance shall be stored so as to
prevent mechanical damage from
occurring.
• A warning that the appliance shall be
stored in a well-ventilated area where the
room size corresponds to the room area
as specified for operation.
• Any person who is involved with working
on or breaking into a refrigerant circuit
should hold a current valid certificate from
an industry-accredited assessment
authority, which authorises their
competence to handle refrigerants safely
in accordance with an industry recognised
assessment specification.
• Servicing shall only be performed as
recommended by the equipment
manufacturer. Maintenance and repair
requiring the assistance of other skilled
personnel shall be carried out under the
supervision of the person competent in
the use of flammable refrigerants.
• DO NOT modify the length of the power
cord or use an extension cord to power
the unit.
• DO NOT share a single outlet with other
electrical appliances. Improper power
supply can cause fire or electrical shock.
• Please follow the instruction carefully to
handle, install, clear, service the air
conditioner to avoid any damage or
hazard. Flammable Refrigerant R32 is used
within air conditioner. When maintaining
or disposing the air conditioner, the
refrigerant (R32 or R290) shall be
recovered properly, shall not discharge to
air directly.
• No any open fire or device like switch
which may generate spark/arcing shall be
around air conditioner to avoid causing
ignition of the flammable refrigerant used.
Please follow the instruction carefully
tostore or maintain the air conditioner to
prevent mechanical damage from
occurring.
• Flammable refrigerant - R32 is used in air
conditioner. Please follow the instruction
carefully to avoid any hazard.
• The refrigerating system should not
receive maintenance, service, or repair by
any person.
• Ensure that the area is in the open or that
it is adequately ventilated before breaking
into the system or conducting any hot
work. A degree of ventilation shall
continue during the period that the work
is carried out. The ventilation should
safely disperse any released refrigerant
and preferably expel it externally into the
atmosphere.
• Check that cabling will not be subject to
wear, corrosion, excessive pressure,
vibration, sharp edges or any other
adverse environmental effects. The check
shall also take into account the effects of
aging or continual vibration from sources
such as compressors or fans.
• Under no circumstances shall potential
sources of ignition be used in the
searching for or detection of refrigerant
leaks. A halide torch (or any other
detector using a naked flame) shall not be
used. The following leak detection
methods are deemed acceptable for all
refrigerant systems. Electronic leak
detectors may be used to detect
refrigerant leaks but, in the case of
FLAMMABLE REFRIGERANTS, the
sensitivity may not be adequate, or may
need re-calibration. (Detection equipment
shall be calibrated in a refrigerant-free
area.) Ensure that the detector is not a
potential source of ignition and is suitable
for the refrigerant used. Leak detection
equipment shall be set at a percentage of

6
the LFL of the refrigerant and shall be
calibrated to the refrigerant employed,
and the appropriate percentage of gas
(25% maximum) is confirmed. Leak
detection fluids are also suitable for use
with most refrigerants but the use of
detergents containing chlorine shall be
avoided as the chlorine may react with
the refrigerant and corrode the copper
pipe-work.
NOTE Examples of leak detection fluids are
– bubble method,
– fluorescent method agents.
If a leak is suspected, all naked flames shall
be removed/extinguished.
If a leakage of refrigerant is found contact
local manufacter to replace unit.
IMPORTANT SAFETY INSTRUCTIONS
Plug in & press RESET
READ THIS SECTION BEFORE ATTEMPTING
TO OPERATE AIR CONDITIONER.
Unit must be upright for one hour prior to
operating.
The power supply cord contains a current
device that senses damage to the power
cord. To test your power supply cord do the
following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO
buttons on the plug head. Press the TEST
button. You will notice a click as the
RESET button pops out.
3. Press the RESET button. Again you will
notice a click as the button engages.
4. The power supply cord is now supplying
electricity to the unit. (This is also
indicated by a light on the plug head).
Operation of Current Device
CAUTION
• This appliance is not intended for use by
persons (including children) with reduced
physical ,sensory or mental capabilities or
lack of experience and knowledge, unless
they have been given supervision or
instruction concerning use of the
appliance by a person responsible for their
safety.
• Children should be supervised to ensure
that they do not play with the appliance.
• If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in
order to avoid a hazard.
• The appliance shall be installed in
accordance with national wiring
regulations.
NOTE
• Do not use this device to turn the unit on
or off.
• Always make sure the RESET button is
pushed in for correct operation.
• The power supply cord must be replaced
if it fails to reset when either the TEST
button is pushed, or it cannot be reset. A
new one can be obtained from the
product manufacturer.
• If power supply cord is damaged, it
CANNOT be repaired. It MUST be replaced
by one obtained from the product
manufacturer.

8AIR CONDITIONER FEATURES
A CB D E F G H I
ELECTRONIC CONTROL
Before you begin, thoroughly familiarize yourself with the control panel and remote as
shown below and all its functions, then follow the symbol for the functions you desire. The
unit can be controlled by the touch pad alone or with the remote.
Light Feature:
The display and all LED indicators on the
control panel of the unit can be turned o
by pressing the "Light" button on the
remote control. If any other button of the
control panel and remote control is pressed
after that, the unit will beep to indicate it
works as the corresponding direction of
pressing specific button, and the display and
LED indicators will illuminate accordingly,
but they will turn o again in 5 seconds if no
further operation.
Press the "Light" button again or unplug the
unit to cancel this setting.
Battery Size: AAA
Warning: Do not mix old and new batteries.
Do not mix alkaline, standard (carbon-zinc),
or rechargeable (nickel-cadmium) batteries.
Caution for ingestion. Keep out of the reach
of children.
REMOTE CONTROL
Air Conditioner Features
A
B
Turns Unit On Or O
C
Eco Feature
D
Sleep Feature
Sets Mode
FSets Fan Speed
GCheck Filter Reset Button
HActivates Timer
IRemote Temp Sensing Indicator
(Some Models)
EDisplays Temperature/time
JAdjusts Temperature Or Time
J
WITH DISPLAY &
REMOTE
SENSING BUTTON
STANDARD REMOTE

9OPERATING INSTRUCTIONS
NOTE
The following instructions represent the
touch pad. The same instructions can be
used for the remote control.
TO TURN UNIT ON:
PRESS ON/OFF BUTTON
DO THIS:
YOU WILL SEE:
NOTE: The unit will run in Cool mode with
Eco feature and Auto fan speed setting
when used for the first time. With the Eco
feature, when the room temperature is below
the set temperature, the fan will continue to
run for 3 minutes after the compressor shuts
o. The fan then cycles on for 2 minutes at 10
minute intervals until the room temperature
is above the set temperature, at which time
the compressor turns back on. Eco feature
can be activated or deactivated by pressing
Eco button, but it is invalid in fan only mode.
PRESS MODE BUTTON
CHOOSE COOL
DO THIS:
AUTO FEATURE:
Note: This mode is a fixed combination of
Cool mode and Auto fan speed setting. In
this mode, the fan speed can not be selected
manually.
Note: In this mode, the fan remains on all the
time with the compressor cycling on and o
when room temperature is reached.
YOU WILL SEE:
YOU WILL SEE:
COOL FEATURE:
TO CHANGE TEMPERATURE SETTlNG:
PRESS MODE BUTTON
CHOOSE AUTO
DO THIS:
PRESS TO LOWER
PRESS TO RAISE
DO THIS:

10 OPERATING INSTRUCTIONS
Note: The fan speed can be selected among
four settings: Auto, Lo(Low), Med(Medium)
and Hi(High), unless the unit runs in "Auto"
or "Dry" mode, or the Sleep feature is
activated.
Note: Tap or hold either up ( ) or down ( )
button until the desired temperature is seen
on the display. This temperature will be
automatically maintained anywhere between
62 °F (17 °C) and 86 °F (30 °C). If you want
the display to read the actual room
temperature. See "To Operate on Fan Only"
section.
YOU WILL SEE:
Note: Fan starts at Low Speed and adjusts
to a proper speed according to the room
temperature dictates. For example, if the
room doesn't get too warm, it will stay at
the slowest speed. If the room temperature
rises quickly, such as a door being opened, it
will automatically go to the highest speed.
The fan speeds will re-adjust back to the
slowest speed as the room returns to the
original set temperature.
YOU WILL SEE:
TO ADJUST FAN SPEEDS:
YOU WILL SEE:
PRESS TO SELECT
DO THIS:
TO USE AUTO FAN FEATURE:
PRESS FAN BUTTON,
CHOOSE AUTO
DO THIS:
TO OPERATE ON FAN ONLY:
PRESS MODE BUTTON
CHOOSE FAN ONLY
DO THIS:

11OPERATING INSTRUCTIONS
Note: Use this function only when cooling is
not desired, such as for room air circulation
or to exhaust stale air on some models.
(Remember to open the vent during this
function, but keep it closed during cooling
for maximum cooling eciency.) You can
choose any fan speed you prefer.
During this function, the display will show
the actual room temperature, not the set
temperature as in the cooling mode.
Note: In this mode, the air conditioner will
work like a dehumidifier, but it will cool the
room down meanwhile. The temperature
can be adjusted between 62 °F (17 °C) and
86 °F (30 °C) and fan speed will be held at
“Lo”.
Note: In this mode, the unit will select Auto
fan speed automatically, and the selected
temperature will increase by 2 °F 30 minutes
after the mode is selected. The temperature
will then increase by another 2 °F after an
additional 30 minutes. This new temperature
will be maintained for 7 hours before it
returns to the originally selected
temperature. This ends the "Sleep" mode
and the unit will continue to operate as
originally programmed. The "Sleep" mode
program can be cancelled at any time
during operation by again pressing the
"Sleep", “Fan speed” or “Mode” button.
Note: This feature is a reminder to clean the
Air Filter (See Care and Cleaning) for more
ecient operation. The LED (light) will
illuminate after 250 hours of operation. To
reset after cleaning the filter, press the
"Filter Reset" button and the light will go o.
YOU WILL SEE:
DRY MODE:
YOU WILL SEE:
PRESS MODE BUTTON
CHOOSE DRY
DO THIS:
SLEEP FEATURE:
CHECK FILTER FEATURE, YOU WILL SEE:
YOU WILL SEE:
PRESS SLEEP
BUTTON
DO THIS:

12 OPERATING INSTRUCTIONS
To delay stop(or start), press the Timer
button when the unit is power-on(or
power-o), then the "timer o" indicator(or
"timer on" indicator) will illuminate. Then
adjust timer setting, tap or hold the UP
arrow ( ) or the DOWN arrow ( ) to
change delay timer at 0.5 hour increments,
up to 10 hours, then at 1 hour increments up
to 24 hours. The setting will be confirmed
automatically in 5 seconds, then the control
will count down the time(8, 7.5, 7, etc.) left,
and all other settings will remain the same
as they were before the timer setting is
confirmed, until stop(or start).
This feature can be activated from the
remote control ONLY, the unit must be in a
cooling mode. To activate the remote
sensing feature, point the remote control
towards the unit and press the Remote
Sensing button. Next, use the “ ” buttons
to set the desired temperature at the
remote. (Note that the set temperature will
only be displayed on the unit itself ). The
LIGHT on the unit control will illuminate to
indicate it receives the signal. The LIGHT on
the remote control will pulse each time it
sends a signal. lt will periodically send this
signal until the feature is deactivated by
pressing the remote sensing button again. lf
the unit does not receive the remote sensing
signal during any 7 minute interval, the
Remote Sensing feature will halt until the
unit receives signal from the remote control
again. The display on the remote control
indicates the temperature at the remote
ONLY.
Setting combination of “delay stop
delay start” or “delay start delay stop”
is workable. Both "timer o" indicator and
"timer on" indicator will illuminate then. The
timer setting can be canceled by either
pressing and holding the timer button for 2
seconds, or pressing the power on/o
button at any time to turn o the unit
directly.
PRESS FILTER
RESET BUTTON
DO THIS:
TIMER: DELAY STOP/START FEATURE:
REMOTE SENSING FEATURE
(on some models):
YOU WILL SEE HOW MUCH TIME IS
CHOSEN:
PRESS UP/DOWN
BUTTONS
THEN DO THIS:
PRESS TIMER
BUTTON
FIRST DO THIS:
turn off
turn on
PRESS REMOTE
SENSING BUTTON
DO THIS:

13OPERATING INSTRUCTIONS
The Remote Sensing function can be
terminated either by pressing the Remote
Sensing button again or the main ON/OFF
button on the unit.
YOU WILL SEE:
Remote Sensing indicator
NOTE: Unit display shows the set
temperature. Remote display is actual
temperature.
TO CHANGE TEMPERATURE DISPLAY:
DO THIS:
PRESS AND HOLD THE UP/DOWN
BUTTONS SIMULTANEOUSLY
FOR 3 SECONDS
YOU WILL SEE:
Note: The control is capable of displaying
temperature in degrees Fahrenheit or
degrees Celsius.
YOU WILL SEE:
DO THIS:
PRESS
ON/OFF BUTTON
TO TURN UNIT OFF:
If the display reads "AS" , a sensor has failed.
Contact your Authorized Frigidaire Service
Center.
FAULT CODES:
Now that you have mastered the operating
procedure, here are more features in your
control that you should become familiar
with.
ADDITIONAL THINGS YOU SHOULD KNOW
NOTE
The "Cool" circuit has an automatic 3
minute time delayed start if the unit is
turned o and on quickly. This prevents
overheating of the compressor and possible
circuit breaker tripping. The fan will
continue to run during this time.
Produkt Specifikationer
Mærke: | Frigidaire |
Kategori: | Aircondition |
Model: | FFRE063WAE |
Har du brug for hjælp?
Hvis du har brug for hjælp til Frigidaire FFRE063WAE stil et spørgsmål nedenfor, og andre brugere vil svare dig
Aircondition Frigidaire Manualer

6 Oktober 2024

6 Oktober 2024

3 Oktober 2024

29 September 2024

23 September 2024

19 September 2024

18 September 2024

17 September 2024

17 September 2024

15 September 2024
Aircondition Manualer
- Aircondition DeLonghi
- Aircondition Bosch
- Aircondition Ozito
- Aircondition Sencor
- Aircondition TCL
- Aircondition Zibro
- Aircondition Siemens
- Aircondition Samsung
- Aircondition Wilfa
- Aircondition GE
- Aircondition Daikin
- Aircondition Zanussi
- Aircondition Panasonic
- Aircondition Candy
- Aircondition Gorenje
- Aircondition Tectro
- Aircondition VOX
- Aircondition Concept
- Aircondition LG
- Aircondition AEG
- Aircondition Electrolux
- Aircondition Bauknecht
- Aircondition Whirlpool
- Aircondition Mitsubishi
- Aircondition Master
- Aircondition Sharp
- Aircondition Hotpoint
- Aircondition Melissa
- Aircondition ARGO
- Aircondition Qlima
- Aircondition Daewoo
- Aircondition Korona
- Aircondition Arçelik
- Aircondition Meaco
- Aircondition Sanyo
- Aircondition Baxi
- Aircondition Grundig
- Aircondition Livoo
- Aircondition Toshiba
- Aircondition Klarstein
- Aircondition Furrion
- Aircondition Buderus
- Aircondition Infiniton
- Aircondition Trisa
- Aircondition Princess
- Aircondition Nedis
- Aircondition Emerio
- Aircondition Logik
- Aircondition Bartscher
- Aircondition Be Quiet!
- Aircondition Sauber
- Aircondition Westinghouse
- Aircondition Element
- Aircondition Thomson
- Aircondition Hyundai
- Aircondition Theben
- Aircondition AKAI
- Aircondition Hisense
- Aircondition TriStar
- Aircondition Brandt
- Aircondition Adler
- Aircondition Black And Decker
- Aircondition Camry
- Aircondition Dometic
- Aircondition Mestic
- Aircondition Eurom
- Aircondition Trotec
- Aircondition Blaupunkt
- Aircondition Einhell
- Aircondition Becken
- Aircondition BEKO
- Aircondition Honeywell
- Aircondition Alpina
- Aircondition Clatronic
- Aircondition Mesko
- Aircondition Hitachi
- Aircondition Rowenta
- Aircondition Bavaria
- Aircondition Medion
- Aircondition Ariston Thermo
- Aircondition Haier
- Aircondition TechniSat
- Aircondition Truma
- Aircondition Bomann
- Aircondition Russell Hobbs
- Aircondition Innoliving
- Aircondition Sanus
- Aircondition Vivax
- Aircondition Vaillant
- Aircondition Amana
- Aircondition Kärcher
- Aircondition Calor
- Aircondition Amcor
- Aircondition Carrier
- Aircondition Comfee
- Aircondition Fral
- Aircondition Gree
- Aircondition Wood's
- Aircondition Dimplex
- Aircondition Eberle
- Aircondition Finlux
- Aircondition Telefunken
- Aircondition Tripp Lite
- Aircondition Primo
- Aircondition Orbegozo
- Aircondition Malmbergs
- Aircondition Sigma
- Aircondition Taurus
- Aircondition Sencys
- Aircondition Balay
- Aircondition Exquisit
- Aircondition HQ
- Aircondition Proklima
- Aircondition Elba
- Aircondition Fujitsu
- Aircondition Profilo
- Aircondition Toyotomi
- Aircondition Lanaform
- Aircondition G3 Ferrari
- Aircondition TOSOT
- Aircondition Domo
- Aircondition GlobalTronics
- Aircondition Saunier Duval
- Aircondition Olimpia Splendid
- Aircondition Unold
- Aircondition Aspes
- Aircondition Inventum
- Aircondition Technoline
- Aircondition White Knight
- Aircondition Dantherm
- Aircondition Midea
- Aircondition Bimar
- Aircondition Evolar
- Aircondition Ridgid
- Aircondition Ardes
- Aircondition Suntec
- Aircondition Esatto
- Aircondition SVAN
- Aircondition Everglades
- Aircondition Danby
- Aircondition RCA
- Aircondition ECG
- Aircondition Trebs
- Aircondition General Electric
- Aircondition Proline
- Aircondition Termozeta
- Aircondition OneConcept
- Aircondition Stirling
- Aircondition EcoFlow
- Aircondition Easy Home
- Aircondition Just Fire
- Aircondition Be Cool
- Aircondition Duux
- Aircondition ElectriQ
- Aircondition Rotel
- Aircondition Lavorwash
- Aircondition Kalorik
- Aircondition Cecotec
- Aircondition Rinnai
- Aircondition Airwell
- Aircondition Rittal
- Aircondition Anslut
- Aircondition Meireles
- Aircondition Team
- Aircondition Jocca
- Aircondition Kenmore
- Aircondition Oregon Scientific
- Aircondition Corbero
- Aircondition Orima
- Aircondition SereneLife
- Aircondition Remko
- Aircondition Friedrich
- Aircondition Whynter
- Aircondition Broan
- Aircondition Bestron
- Aircondition Philco
- Aircondition Sôlt
- Aircondition Fuave
- Aircondition Kunft
- Aircondition Climadiff
- Aircondition Kogan
- Aircondition LERAN
- Aircondition DCG
- Aircondition Emerson
- Aircondition Ravanson
- Aircondition BLUEPALM
- Aircondition Insignia
- Aircondition Consul
- Aircondition Jocel
- Aircondition Heller
- Aircondition Fronius
- Aircondition Ufesa
- Aircondition InAlto
- Aircondition Keystone
- Aircondition Manta
- Aircondition HTW
- Aircondition Orava
- Aircondition NewAir
- Aircondition IFB
- Aircondition Mistral
- Aircondition PRIME3
- Aircondition Daitsu
- Aircondition Daizuki
- Aircondition Aconatic
- Aircondition KDK
- Aircondition Eufab
- Aircondition BOSFOR
- Aircondition Itho
- Aircondition Mabe
- Aircondition Teesa
- Aircondition Heinner
- Aircondition Guzzanti
- Aircondition Defy
- Aircondition Premium
- Aircondition Kubo
- Aircondition Ansonic
- Aircondition Kelvinator
- Aircondition Listo
- Aircondition Challenge
- Aircondition Alpatec
- Aircondition Godrej
- Aircondition Maiko
- Aircondition Essentiel B
- Aircondition Equation
- Aircondition Edy
- Aircondition Edgestar
- Aircondition Maxicool
- Aircondition Equator
- Aircondition Argoclima
- Aircondition Fairland
- Aircondition DEXP
- Aircondition Teco
- Aircondition Livington
- Aircondition Chigo
- Aircondition Hokkaido
- Aircondition Tarrington House
- Aircondition Gutfels
- Aircondition Firstline
- Aircondition VänEE
- Aircondition Holland Electro
- Aircondition Mayer
- Aircondition Evapolar
- Aircondition Elgin
- Aircondition Tronix
- Aircondition Liebert
- Aircondition ARCTIC WIND
- Aircondition Perfect Aire
- Aircondition Avalon Bay
- Aircondition SMC
- Aircondition D-Let
- Aircondition Braemar
- Aircondition Klimaire
- Aircondition Ebro
- Aircondition SEEGER
- Aircondition SPT
- Aircondition Simplicity
- Aircondition Starlyf
- Aircondition Aerian
- Aircondition Moa
- Aircondition Fuji Electric
- Aircondition Polocool
- Aircondition Convair
- Aircondition Kibernetik
- Aircondition Companion
- Aircondition Prem-i-air
- Aircondition Arcoaire
- Aircondition Céliera
- Aircondition Bodin
- Aircondition Magnavox
- Aircondition AFINTEK
- Aircondition Brivis
- Aircondition MRCOOL
- Aircondition Volteno
- Aircondition B-Air
- Aircondition Monzana
- Aircondition Trilec
- Aircondition Kaden
- Aircondition Geist
- Aircondition GoldAir
- Aircondition Avallon
- Aircondition Big Ass Fans
- Aircondition Columbia Vac
- Aircondition TURBRO
- Aircondition House & Luft
- Aircondition Bonaire
- Aircondition Evapcool
- Aircondition Protector
- Aircondition Vostok
- Aircondition American Comfort
- Aircondition Ocean Breeze
- Aircondition Quirky
- Aircondition Krone
- Aircondition KwiKool
- Aircondition Arctic King
- Aircondition Artrom
- Aircondition Senville
- Aircondition Climachill
- Aircondition Commercial Cool
- Aircondition Riffel
- Aircondition Coolix
- Aircondition Heat Controller
- Aircondition Luma Comfort
- Aircondition Norpole
- Aircondition Kaco
- Aircondition Omega Altise
- Aircondition Goodwe
- Aircondition Swegon
- Aircondition JHS
- Aircondition FREONIC
- Aircondition SHE
- Aircondition Electroline
- Aircondition KuulAire
- Aircondition Cool-Space
- Aircondition Koldfront
Nyeste Aircondition Manualer

9 April 2025

9 April 2025

4 Marts 2025

28 Februar 2025

28 Februar 2025

28 Februar 2025

28 Februar 2025

28 Februar 2025

28 Februar 2025

28 Februar 2025