Frigidaire GL30WC41EB Manual

Frigidaire Ventilator GL30WC41EB

Læs nedenfor 📖 manual på dansk for Frigidaire GL30WC41EB (8 sider) i kategorien Ventilator. Denne guide var nyttig for 31 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/8
1
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or telephone
number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and
lock the service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means can-
not be locked, securely fasten a prominent warning device, such as a
tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards, in-
cluding fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the National Fire Pro-
tection Association (NFPA), and the American Society of Heating, Re-
frigeration and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. To reduce the risk of fire or electric shock, do not use this range hood
with an additional speed control device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. Use with approved cord-connection kit only.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers cause
smoking and greasy spillovers that may ignite. Heat oils slowly on low or
medium settings.
2. Always turn hood ON when cooking at high heat or when cooking flaming
foods.
3. Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size of
the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A
RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray,
then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the
ames do not go out immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent steam
explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with
the homeowner.
Homeowner: Operating and
Cleaning information on page 6.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced impel-
lers, keep drywall spray, construction dust, etc. off power unit.
3. For best capture of cooking impurities, your range hood should be
mounted so that the top of the hood is 24-30” above the cooking sur-
face.
4. Please read specification label on product for further information and
requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
“PREPARE HOOD LOCATION”
Run ductwork from roof or wall cap, and electrical wiring from service
panel - to installation location
“PREPARE THE HOOD”
Get your hood ready for installation
“CONNECT WIRING”
Make electrical wiring connections to hood
“INSTALL HOOD”
Secure hood to cabinet and ductwork - install bulbs and filters
• “OPERATION”
How to use the hood controls
• “CLEANING”
Keep your hood in top working condition
“SERVICE PARTS”
Key numbers and exploded view of hood components
• “WARRANTY”
One-year limited warranty and how to contact us
NOTE If hood is to be installed Non-Ducted:
Purchase a set of (2) non-ducted filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
Patent No.: US D450, 829 S
!!
FOR DOMESTIC COOKING ONLY
!
PROFESSIONAL SERIES MODELS
PL30WC4IEC
PL36WC4IEC
GALLERY SERIES MODELS
GL30WC4IES
GL36WC4IES
GL30WC4IEB
GL36WC4IEB


Produkt Specifikationer

Mærke: Frigidaire
Kategori: Ventilator
Model: GL30WC41EB

Har du brug for hjælp?

Hvis du har brug for hjælp til Frigidaire GL30WC41EB stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ventilator Frigidaire Manualer

Ventilator Manualer

Nyeste Ventilator Manualer

Be Cool

Be Cool BC121TU2201F Manual

19 November 2024
Emerio

Emerio FN-114204.11 Manual

16 November 2024
Ardes

Ardes Freddy AR5T75 Manual

16 November 2024
Midea

Midea FTS30-9BR Manual

16 November 2024
OK

OK OSF 4332 B RC Manual

16 November 2024
Biltema

Biltema 83-017 Manual

12 November 2024
Biltema

Biltema 83-021 Manual

12 November 2024
Biltema

Biltema 83-014 Manual

12 November 2024
Hunter

Hunter Fonthill Manual

12 November 2024