WARNING
• Installation of this product must be done by experienced service technicians or
professional installers only in accordance with this manual. Installation by nonprofes-
sional or improper installation of the product may cause serious accidents such as
injury, water leakage, electric shock, or re. If the product is installed in disregard of
the instructions in this manual, it will void the manufacturer’s warranty.
• To avoid getting an electric shock, never touch the electrical components soon
after the power supply has been turned off. After turning off the power, always wait
10 minutes or more before you touch the electrical components.
• Do not turn on the power until all work has been completed. Turning on the power
before the work is completed can cause serious accidents such as electric shock or
re.
• If refrigerant leaks while work is being carried out, ventilate the area. If the refrigerant
comes in contact with a ame, it produces a toxic gas.
• Installation must be performed in accordance with regulations, codes, or standards
for electrical wiring and equipment in each country, region, or the installation place.
• -Do not use this equipment with air or any other unspecied refrigerant in the refriger
ant lines. Excess pressure can cause a rupture.
• During installation, make sure that the refrigerant pipe is attached rmly before you
run the compressor.
Do not operate the compressor under the condition of refrigerant piping not attached
properly with 3-way valve open. This may cause abnormal pressure in the refrigera-
tion cycle that leads to rupture and even injury.
• When installing or relocating the air conditioner, do not mix gases other than the
specied refrigerant (R32) to enter the refrigerant cycle.
If air or other gas enters the refrigerant cycle, the pressure inside the cycle will rise to
an abnormally high value and cause rupture, injury, etc.
• To connect the indoor unit and outdoor unit, use air conditioner piping and cables
available locally as standard parts. This manual describes proper connections using
such installation set.
• Do not modify power cable, use extension cable or branch wiring. Improper use may
cause electric shock or re by poor connection, insufcient insulation or over current.
• Do not purge the air with refrigerants but use a vacuum pump to vacuum the installa-
tion.
• There is not extra refrigerant in the outdoor unit for air purging.
• Use a vacuum pump for R32 or R410A exclusively.
• Using the same vacuum pump for different refrigerants may damage the vacuum
pump or the unit.
• Use a clean gauge manifold and charging hose for R32 or R410A exclusively.
• Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
• The appliance shall be stored in a room without continuously operating ignition
sources (for example: open ames, an operating gas appliance or an operating
electric heater).
• Do not pierce or burn.
• Be aware that refrigerants may not contain an odour.
• During the pump-down operation, make sure that the compressor is turned off before
you remove the refrigerant piping.
Do not remove the connection pipe while the compressor is in operation with 3-way
valve open.
This may cause abnormal pressure in the refrigeration cycle that leads to rupture and
even injury.
• This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they
do not play with the appliance.
CAUTION
• For the air conditioner to work appropriately, install it as written in this manual.
• The appliance shall not be installed in an unventilated space, if that space is smaller
than 1.61 m2.
• This product must be installed by qualied personnel with a capacity certication of
handling refrigerant uids. Refer to regulation and laws in use on installation place.
• Install the product by following local codes and regulations in force at the place of
installation, and the instructions provided by the manufacturer.
• This product is part of a set constituting an air conditioner. The product must not be
installed alone or be installed with non-authorized device by the manufacturer.
• Always use a separate power supply line protected by a circuit breaker operating on
all wires with a distance between contact of 3 mm for this product.
• To protect the persons, earth (ground) the product correctly, and use the power cable
combined with an Earth Leakage Circuit Breaker (ELCB).
• This product is not explosion proof, and therefore should not be installed in explosive
atmosphere.
• This product contains no user-serviceable parts. Always consult experienced service
technicians for repairing.
• When installing pipes shorter than 3 m, sound of the outdoor unit will be transferred
to the indoor unit, which will cause large operating sound or some abnormal sound.
• When moving or relocating the air conditioner, consult experienced service techni-
cians for disconnection and reinstallation of the product.
• Do not touch the ns of the heat exchanger. Touching the heat exchanger ns could
result in damage to the ns or personal injury such as skin rupture.
AIR CONDITIONER
OUTDOOR UNIT
INSTALLATION MANUAL
PART No. 9319205281
1. SAFETY PRECAUTIONS
• Be sure to read this manual thoroughly before installation.
• The warnings and precautions indicated in this manual contain important information
pertaining to your safety. Be sure to observe them.
• Hand this manual, together with the operating manual, to the customer. Request the
customer to keep them on hand for future use, such as for relocating or repairing the
unit.
WARNING
Indicates a potentially or imminently hazardous situation
which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation that may result in
minor or moderate injury or damage to property.
[Original instructions] For authorized service personnel only.
EnglishDeutschFrançaisEspañolItalianoEλληvIkάPortuguêsРусский
Türkçe
Türkçe
Contents
1. SAFETY PRECAUTIONS .......................................................................1
2. PRODUCT SPECIFICATION ................................................................. 3
2.1. Installation tools ........................................................................... 3
2.2. Accessories 4 .................................................................................
2.3. Pipe requirements 4 .......................................................................
2.4. Electrical requirements 5 ................................................................
2.5. Additional charge amount ............................................................ 6
2.6. General information ..................................................................... 6
3. INSTALLATION WORK .......................................................................... 6
3.1. Installation dimensions 6 ................................................................
3.2. Mounting the unit ......................................................................... 7
3.3. Removing and replacing part 8 .......................................................
3.4. Drain installation 8 ..........................................................................
3.5. Pipe installation 8 ...........................................................................
3.6. Sealing test .................................................................................. 9
3.7. Vacuum process .......................................................................... 9
3.8. Additional charging ....................................................................10
3.9. Electrical wiring .......................................................................... 10
4. TEST RUN 12 ............................................................................................
4.1. Make a TEST RUN in accordance with the installation
Manual for the indoor unit 12 ..........................................................
5. FINISHING 12 ...........................................................................................
5.1. Installing insulation 12 ....................................................................
6. PUMP DOWN 12 .......................................................................................
Produkt Specifikationer
Mærke: | Fujitsu |
Kategori: | Airco |
Model: | AOYG18KBTA2 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Fujitsu AOYG18KBTA2 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Airco Fujitsu Manualer
17 September 2024
17 September 2024
15 September 2024
13 September 2024
13 September 2024
13 September 2024
6 September 2024
6 September 2024
6 September 2024
6 September 2024
Airco Manualer
- Airco DeLonghi
- Airco Bosch
- Airco Ozito
- Airco Sencor
- Airco TCL
- Airco Zibro
- Airco Siemens
- Airco Samsung
- Airco Wilfa
- Airco GE
- Airco Daikin
- Airco Panasonic
- Airco Candy
- Airco Gorenje
- Airco VOX
- Airco Concept
- Airco LG
- Airco AEG
- Airco Electrolux
- Airco Bauknecht
- Airco Whirlpool
- Airco Mitsubishi
- Airco Master
- Airco Sharp
- Airco Hotpoint
- Airco ARGO
- Airco Qlima
- Airco Daewoo
- Airco Korona
- Airco Arçelik
- Airco Meaco
- Airco Sanyo
- Airco Baxi
- Airco Livoo
- Airco Toshiba
- Airco Klarstein
- Airco Furrion
- Airco Princess
- Airco Nedis
- Airco Emerio
- Airco Be Quiet!
- Airco Sauber
- Airco Westinghouse
- Airco Element
- Airco Thomson
- Airco Hisense
- Airco TriStar
- Airco Brandt
- Airco Adler
- Airco Black And Decker
- Airco Dometic
- Airco Eurom
- Airco Trotec
- Airco Einhell
- Airco Becken
- Airco BEKO
- Airco Honeywell
- Airco Clatronic
- Airco Hitachi
- Airco Rowenta
- Airco Medion
- Airco Ariston Thermo
- Airco Haier
- Airco Truma
- Airco Bomann
- Airco Innoliving
- Airco Vivax
- Airco Vaillant
- Airco Amana
- Airco Calor
- Airco Carrier
- Airco Comfee
- Airco Fral
- Airco Gree
- Airco Wood's
- Airco Dimplex
- Airco Finlux
- Airco Telefunken
- Airco Tripp Lite
- Airco Primo
- Airco Orbegozo
- Airco Sigma
- Airco Proklima
- Airco Elba
- Airco Profilo
- Airco Lanaform
- Airco G3 Ferrari
- Airco TOSOT
- Airco Domo
- Airco GlobalTronics
- Airco Saunier Duval
- Airco Olimpia Splendid
- Airco Unold
- Airco Aspes
- Airco Inventum
- Airco White Knight
- Airco Midea
- Airco Frigidaire
- Airco Evolar
- Airco Ardes
- Airco Suntec
- Airco Esatto
- Airco SVAN
- Airco Everglades
- Airco Danby
- Airco General Electric
- Airco Proline
- Airco Termozeta
- Airco Easy Home
- Airco Be Cool
- Airco ElectriQ
- Airco Rotel
- Airco Kalorik
- Airco Cecotec
- Airco Rinnai
- Airco Meireles
- Airco Team
- Airco Kenmore
- Airco Oregon Scientific
- Airco Corbero
- Airco Orima
- Airco SereneLife
- Airco Friedrich
- Airco Whynter
- Airco Broan
- Airco Bestron
- Airco Philco
- Airco Fuave
- Airco Kunft
- Airco Kogan
- Airco LERAN
- Airco DCG
- Airco Emerson
- Airco Ravanson
- Airco BLUEPALM
- Airco Consul
- Airco Jocel
- Airco Fronius
- Airco Ufesa
- Airco InAlto
- Airco Keystone
- Airco Manta
- Airco Orava
- Airco NewAir
- Airco IFB
- Airco Mistral
- Airco PRIME3
- Airco Daizuki
- Airco Aconatic
- Airco KDK
- Airco BOSFOR
- Airco Mabe
- Airco Heinner
- Airco Guzzanti
- Airco Kubo
- Airco Ansonic
- Airco Godrej
- Airco Maiko
- Airco Essentiel B
- Airco Edy
- Airco Maxicool
- Airco Equator
- Airco Argoclima
- Airco Teco
- Airco Livington
- Airco Chigo
- Airco Tarrington House
- Airco Firstline
- Airco VänEE
- Airco Holland Electro
- Airco Mayer
- Airco Evapolar
- Airco Elgin
- Airco Tronix
- Airco Liebert
- Airco ARCTIC WIND
- Airco Perfect Aire
- Airco Avalon Bay
- Airco SMC
- Airco D-Let
- Airco Braemar
- Airco Klimaire
- Airco SEEGER
- Airco SPT
- Airco Fuji Electric
- Airco Polocool
- Airco Convair
- Airco Prem-i-air
- Airco Céliera
- Airco Bodin
- Airco Brivis
- Airco MRCOOL
- Airco Volteno
- Airco B-Air
- Airco Trilec
- Airco Kaden
- Airco GoldAir
- Airco Big Ass Fans
- Airco Columbia Vac
- Airco Bonaire
- Airco Vostok
- Airco American Comfort
- Airco Heat Controller
- Airco Omega Altise
- Airco Goodwe
- Airco Swegon
- Airco SHE
- Airco KuulAire
- Airco Cool-Space
- Airco Koldfront
Nyeste Airco Manualer
18 September 2024
18 September 2024
18 September 2024
18 September 2024
18 September 2024
18 September 2024
18 September 2024
18 September 2024
18 September 2024
17 September 2024