Fujitsu ASGG12CPAA-B Manual

Fujitsu Splitter ASGG12CPAA-B

Læs nedenfor 📖 manual på dansk for Fujitsu ASGG12CPAA-B (14 sider) i kategorien Splitter. Denne guide var nyttig for 7 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere

Side 1/14
En-1
WARNING
The appliance shall be installed, operated and stored in a room with a oor area larger
than 2.60 m2
Installation of this product must be done by experienced service technicians or profes-
sional installers only in accordance with this manual. Installation by non-professional
or improper installation of the product might cause serious accidents such as injury,
water leakage, electric shock, or re. If the product is installed in disregard of the
instructions in this manual, it will void the manufacturer’s warranty.
Do not turn on the power until all work has been completed. Turning on the power be-
fore the work is completed can cause serious accidents such as electric shock or re.
If refrigerant leaks when you are working, ventilate the area. If the leaking refrigerant
is exposed to a direct ame, it may produce a toxic gas.
Installation must be performed in accordance with regulations, codes, or standards for
electrical wiring and equipment in each country, region, or the installation place.
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they
do not play with the appliance.
To avoid danger of su󰀨ocation, keep the plastic bag or thin lm used as the packaging
material away from young children.
The appliance shall be stored in a room without continuously operating ignition
sources (for example: open ames, an operating gas appliance or an operating
electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Keep any required ventilation openings clear of obstruction.
If the power cable or the connection cable is damaged, it must be replaced by the
manufacturer, its service agent or similar qualied persons in order to avoid a safety
hazard.
CAUTION
Read carefully all safety information written in this manual before you install or use the
air conditioner.
Install the product by following local codes and regulations in force at the place of
installation, and the instructions provided by the manufacturer.
This product is part of a set constituting an air conditioner. The product must not be
installed alone or be installed with a device not authorized by the manufacturer.
Always use a separate power supply line protected by a circuit breaker operating on
all wires with a distance between contact of 3 mm for this product.
To protect the persons, ground (earth) the product correctly, and use the power cable
combined with an Earth Leakage Circuit Breaker (ELCB).
This product is not explosion proof, and therefore should not be installed in an explo-
sive atmosphere.
To avoid getting an electric shock, never touch the electrical components soon after
the power supply has been turned o󰀨. After turning o󰀨 the power, always wait 5 min-
utes or more before you touch the electrical components.
This product contains no user-serviceable parts. Always consult experienced service
technicians for repairing.
When moving or relocating the air conditioner, consult experienced service technicians
for disconnection and reinstallation of the product.
Do not touch the aluminum ns of heat exchanger built-in the indoor or outdoor unit to
avoid personal injury when you install or maintain the unit.
Do not place any other electrical products or household belongings under the product.
Condensation dripping from the product might get them wet, and may cause damage
or malfunction to the property.
Be careful not to scratch the air conditioner when handling it.
1.1. Precautions for using R32 refrigerant
The basic installation work procedures are the same as conventional refrigerant (R410A,
R22) models.
However, pay careful attention to the following points:
Since the working pressure is 1.6 times higher than that of refrigerant R22 models,
some of the piping and installation and service tools are special. (Refer to “2.1. Instal-
lation tools”.)
Especially, when replacing a refrigerant R22 model with a new refrigerant R32 model,
always replace the conventional piping and flare nuts with the R32 and R410A piping and
are nuts on the outdoor unit side.
For R32 and R410A, the same are nut on the outdoor unit side and pipe can be used.
Models that use refrigerant R32 and R410A have a di󰀨erent charging port thread diam-
eter to prevent erroneous charging with refrigerant R22 and for safety. Therefore, check
beforehand. [The charging port thread diameter for R32 and R410A is 1/2-20 UNF.]
Be more careful than R22 so that foreign matter (oil, water, etc.) does not enter the
piping. Also, when storing the piping ,securely seal the opening by pinching, taping, etc.
(Handling of R32 is similar to R410A.)
AIR CONDITIONER
Wall Mounted Type
INSTALLATION MANUAL
Contents
1. SAFETY PRECAUTIONS .................................................................. 1
1.1. Precautions for using R32 refrigerant ......................................... 1
2. PRODUCT SPECIFICATION ............................................................. 3
2.1. Installation tools .......................................................................... 3
2.2. Accessories ................................................................................ 4
2.3. Pipe requirement ........................................................................ 4
2.4. Electrical requirement ................................................................. 4
2.5. Optional parts ............................................................................. 4
3. INSTALLATION WORK ..................................................................... 4
3.1. Selecting an installation location ................................................ 4
3.2. Removing and replacing parts .................................................... 5
3.3. Pipe installation .......................................................................... 6
3.4. Electrical wiring ........................................................................... 8
3.5. Remote controller installation ..................................................... 9
4. OPTIONAL INSTALLATION WORK .................................................. 9
4.1. Optional kit installation ................................................................ 9
4.2. Group control ............................................................................ 10
5. FUNCTION SETTING...................................................................... 10
5.1. Function details .........................................................................11
6. TEST RUN ....................................................................................... 12
7. FINISHING ...................................................................................... 12
8. CUSTOMER GUIDANCE ................................................................ 12
9. ERROR CODES .............................................................................. 12
PART No. 9387848076-02
1. SAFETY PRECAUTIONS
• Be sure to read this manual thoroughly before installation.
• The warnings and precautions indicated in this manual contain important information
pertaining to your safety. Be sure to observe them.
• Hand this manual, together with the operation manual, to the customer. Request the
customer to keep them on hand for future use, such as for relocating or repairing the
unit.
WARNING Indicates a potentially or imminently hazardous situation
which, if not avoided, could result in death or serious injury.
CAUTION Indicates a potentially hazardous situation that may result in
minor or moderate injury or damage to property.
For authorized service personnel only.


Produkt Specifikationer

Mærke: Fujitsu
Kategori: Splitter
Model: ASGG12CPAA-B

Har du brug for hjælp?

Hvis du har brug for hjælp til Fujitsu ASGG12CPAA-B stil et spørgsmål nedenfor, og andre brugere vil svare dig




Splitter Fujitsu Manualer

Fujitsu

Fujitsu ARYG54LHTA Manual

14 September 2024
Fujitsu

Fujitsu ASHG07KPCA Manual

9 September 2024
Fujitsu

Fujitsu ASEG18KMTE Manual

6 September 2024
Fujitsu

Fujitsu ASEG24KMTE Manual

6 September 2024
Fujitsu

Fujitsu ASEH30KMTB Manual

6 September 2024
Fujitsu

Fujitsu ASEH36KMTB Manual

6 September 2024
Fujitsu

Fujitsu ASHH07KNCA Manual

6 September 2024
Fujitsu

Fujitsu ASEG07KPCE Manual

6 September 2024
Fujitsu

Fujitsu ASHH12KNCA Manual

3 September 2024

Splitter Manualer

Nyeste Splitter Manualer

IFM

IFM EBC118 Manual

7 September 2024
Samsung

Samsung AM018FNNDCH Manual

5 September 2024
Samsung

Samsung AM018FNCDCH Manual

5 September 2024
Samsung

Samsung AM048TXMDCH Manual

5 September 2024
Samsung

Samsung AM036FNMDCH Manual

5 September 2024
Samsung

Samsung AM024FNLDCH Manual

5 September 2024
Samsung

Samsung AM012FNNDCH Manual

5 September 2024
Samsung

Samsung AM024FN4DCH Manual

5 September 2024
Samsung

Samsung AM048FN4DCH Manual

5 September 2024