Fujitsu AXGT24FHTC-B Manual
Fujitsu
Klimaanlæg
AXGT24FHTC-B
Læs nedenfor 📖 manual på dansk for Fujitsu AXGT24FHTC-B (3 sider) i kategorien Klimaanlæg. Denne guide var nyttig for 10 personer og blev bedømt med 4.5 stjerner i gennemsnit af 2 brugere
Side 1/3
1
2
AX SERIES
ROOM AIR CONDITIONER
WIRELESS TYPE
ENGLISH
PART No. 9386269148
Before using this product, read these instructions thoroughly and keep this manual for future reference.
To prevent personal injury, injury to others, or property damage, read this section carefully before you use this product, and be sure to comply following
safety precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classifi ed as follows:
Refer to the rating label with the serial number.
MADE IN THAILAND
OPERATION MANUAL
Safety Precautions
Power Supply
WARNING
This mark warns of death or serious injury.
WARNING
zDo not attempt to install this air conditioner by yourself.
zThis unit contains no user-serviceable parts. Always consult authorized
service personnel for repairs.
zWhen moving, consult authorized service personnel for disconnection
and installation of the unit.
zDo not become over-exposed to cold air by staying in the direct path of
the air fl ow of the air conditioner for extended periods of time.
zDo not insert fi ngers or objects into the outlet port or intake grille.
zDo not start and stop air conditioner operation by turning off the
electrical breaker or disconnecting the power supply plug and so on.
zTake care not to damage the power supply cord.
zDo not modify the power cables, use extension cables, or use any
branches in the wiring. Improper connections, insuffi cient insulation, or
exceeding the allowable current can cause electric shock or fi re.
zDo not bundle the power supply cable.
zIn the event of a malfunction (burning smell, etc.), immediately stop
operation, turn off the electrical breaker or disconnect the power
supply plug, and consult authorized service personnel.
zAlways turn off the electrical breaker or disconnect the power supply
plug whenever cleaning the air conditioner or the air fi lter.
zThis appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible
for their safety. Children should be supervised to ensure that they do
not play with the appliance.
zIf you see lightning or hear thunder, there might be a lightning strike.
To prevent electric shock hazard, turn off the air conditioner by using
the remote controller, and do not touch the unit or the power plug
during thunderstorm.
CAUTION
zProvide occasional ventilation during use.
zDo not direct airfl ow at fi replaces or heating apparatus.
zDo not climb on, or place objects on the air conditioner.
zDo not hang objects from the unit.
zDo not set fl ower vases or water containers on top of air conditioners.
zDo not expose the air conditioner directly to water.
zDo not operate the air conditioner with wet hands.
zDo not pull power supply cord.
zTurn off power source when not using the unit for extended periods.
zCheck the condition of the installation stand for damage.
zDo not place animals or plants in the direct path of the airfl ow.
zDo not drink the water drained from the air conditioner.
zDo not touch the aluminum fi ns of heat exchanger built-in the indoor or
outdoor unit to avoid personal injury when you install or maintain the
unit.
zDo not use in applications involving the storage of foods, plants or
animals, precision equipment, or art works.
zDo not apply any heavy pressure to radiator fi ns.
zOperate only with air fi lter installed.
zDo not block or cover the intake grille and outlet port.
zEnsure that any electronic equipment is at least 1 m away from the
unit.
zAvoid installing the air conditioner near a fi replace or other heating
apparatus.
zWhen installing the unit, take precautions to prevent access by infants.
zDo not use infl ammable gases near the air conditioner.
zAlways turn off the electrical breaker or disconnect the power supply
plug whenever cleaning the air conditioner or the air fi lter.
CAUTION
This mark warns of injury or damage to property.
Air outlet
Warm air is blown out.
Intake grille
Air is taken in here.
Air inlet
(Both sides)
Air fi lter
Removes all dirt and
dust from the air.
Screw
Securing the front panel
to the unit.
Remote control
signal receiver
Signals from the remote control unit
are received here.
OPERATION indicator
(Green)
Lights when unit is operating.
Flashes quickly for about 1 second
when a signal is received from the
remote control unit.
Front panel
Unit Overview
Preparation
Loading batteries (AAA/R03/LR03×2) on the remote controller
Basic Operations
Mode Operation (COOL, DRY, and FAN)
Automatic Operation
Temperature and Humidity Range
Remote Controller Overview
TIMER indicator (Orange)
Lights during ON TIMER, OFF TIMER, and SLEEP
TIMER.
If the TIMER indicator fl ashes when the timer is
operating, it indicates that a fault has occurred with
the timer setting.
MANUAL AUTO button
Pressed 10 seconds or less (AUTOMATIC
mode)
• Fan speed will be set to “AUTO” and the
thermostat will be set for 24 °C.
• To stop operation, either press the MANUAL
AUTO button once again.
Pressed 10 seconds or more (Forced cooling)
• The forced cooling operation is used at the
time of installation.
Only for authorized service personnel’s use.
• When the forced cooling operation starts by
any chance, press START/STOP button to
stop the operation.
SUPER WAVE indicator (Green)
Lights during SUPER WAVE working.
Set temperature / Timer Indicator
Shows the thermostat setting.
During the timer mode is set, the function is
displayed. (After the timer mode is shown, the
thermostat setting is returned to temperature
indication.)
Fan Speed Indicator
Shows the current fan speed.
Transmit Indicator
Displayed when a signal is sent to the air
conditioner.
Signal Transmitter
Controls signal sent to the air conditioner from here.
FAN button
Press to select fan speed. (AUTO, HIGH, MED, and
LOW).
SUPER WAVE button
Use to set the desired airfl ow direction.
START/STOP button
Press to start and stop operation.
RESET button
This button is used when replacing batteries.
CANCEL button
Press to cancel the setting time.
ON TIMER button
Use to set time for ON the air conditioner.
Power supply plug
Vertical airfl ow direction louvers
Control airfl ow in the vertical (up-down) direction.
Horizontal airfl ow direction
louvers
Control airfl ow in the horizontal (right-left) direction.
Drain tube
(At the bottom of the backside)
Moisture condensed from the air during cooling is
drained here.
Remote controller display
* The accompanying illustration depicts the
display with all indicators lighted; in actual use,
however, only those indicators currently required
are displayed.
Operation Mode Indicator
Shows the operation mode
(AUTO, COOL, DRY, and FAN)
Timer Mode Indicator
Shows the timer mode
O : “OFF TIMER” symbol
I : “ON TIMER” symbol
: “SLEEP TIMER” symbol
MODE button
Press to select operating mode
(AUTO, COOL, DRY, FAN)
SET TEMP. buttons ( / )
Press to set the unit’s thermostat.
TEST RUN button
This button is used when testing the air
conditioner after installation.
Do not use under normal condition.
SLEEP button
Use to set time for OFF the air conditioner.
OFF TIMER button
Use to set time for OFF the air conditioner.
WARNING
Take precautions to prevent infants from accidentally swallowing
batteries.
CAUTION
When not using the remote controller for an extended period,
remove the batteries to avoid possible leakage and damage to the
unit.
If leaking battery fl uid comes in contact with your skin, eyes, or
mouth, immediately wash with copious amounts of water, and
consult your physician.
Dead batteries should be removed quickly and disposed of properly,
either by placing in a public battery collection receptacle, or by
returning to a properly equipped dealer.
1Press and slide the battery
compartment lid on the reverse
side to open it.
Slide in the direction of the arrow
while pressing the mark.
2Insert batteries.
Be sure to align the battery polarities ( ) correctly.
3Close the battery compartment lid.
Notes:
Never mix new and used batteries, or batteries of diff erent types.
Batteries should last about 1 year under normal use. If the remote
controller’s operating range becomes appreciably reduced, replace the
batteries and press the reset button with the tip of a ballpoint pen or
other small object.
Notes:
Signals will not be transmitted properly if a wall, curtain, or other object
is between the air conditioner and the remote control unit.
The air conditioner may fail to operate properly if strong direct light
is allowed to strike the signal receiver. Use a curtain to shade strong
sunlight from windows, and place strong lamps at a distance away from
the signal receiver.
Do not place the remote control unit in locations where it may be
subjected to heat from direct sunlight or from heating apparatus.
Do not subject the remote control unit to strong impacts, and do not
allow water or other liquids to splash on it.
When the remote control unit is used in rooms furnished with instant-
lighting type fl uorescent lamps, the air conditioner may fail to receive
control signals correctly. Consult with authorized service personnel
when purchasing a new fl uorescent lamp.
If another electric appliance is operated by the remote control unit move
the appliance away or consult with authorized service personnel.
Turn on the power
Connect the power plug to an electrical point.
To use the remote controller
The remote control unit must be pointed at signal receiver to operate
correctly.
When a signal is properly received by the air conditioner, a beeping
sound will be heard.
If no beep is heard, press the remote control unit button again.
Connect securely,
without looseness.
In the case of direct line
connections, turn on the breaker.
Operating range:
Within about 7 meters
Signal receiver
Cooling: Use to cool your room.
Drying: Use for gently cooling while dehumidifying your room.
You cannot heat the room during drying mode.
During drying mode, the unit will operate at low speed, in order
to adjust room humidity, the unit’s fan may stop from time to time.
Also, the fan may operate at very low speed when detecting room
humidity.
The fan speed cannot be changed manually when drying mode has
been selected.
Fan: Use to circulate air through your room without changing its
temperature.
You cannot use the unit to heat and cool your room.
Each time the MODE button is pressed, the mode will change in the
following order. AUTO
FAN
COOL
DRY
About 3 seconds later, the entire display will reappear.
Thermostat Setting
button: Press to raise the thermostat setting.
button: Press to lower the thermostat setting.
Thermostat setting range:
AUTO .................................. 18-30 °C
Cooling/Dry ......................... 18-30 °C
Fan Speed Setting
Each time the button is pressed, the fan speed changes in the following
order: AUTO HIGH MED LOW
About 3 seconds later, the entire display will reappear.
When the FAN CONTROL is set to AUTO:
COOL: Operation begins and as the room temperature approaches that of
the thermostat setting, the fan speed switches to the low setting.
Vertical airfl ow direction louvers:
Rotate the vertical airfl ow louvers upward, or downward.
Right-Left Airfl ow-direction Louvers:
Control airfl ow in the horizontal (right-left) direction.
When the SUPER WAVE button is pressed, the louvers move and
blow air to the left and right.
To stop SUPER WAVE operation, press the button again.
Airfl ow Direction Adjustment
Vertical airfl ow direction louvers
When Automatic operation fi rst selected, the fan will operate at low
speed for 1 minute, during which time the unit detects the room
conditions and selects the proper operating mode.
If the diff erence between thermostat setting and actual room
temperature is more than +2ºC→Cooling operation
If the diff erence between thermostat setting and actual room
temperature is less than +2ºC→Dry operation
If the mode automatically selected by the unit is not what you wish,
select one of the mode operation (COOL, DRY, and FAN.)
1Press the START/STOP button.
The air conditioner will start operation.
2Press the MODE button to select AUTO.
The operating mode “AUTO” will appear alone in the display. The
transmit indicator will fl ash to indicate the command has been sent,
and about 3 seconds later the entire display panel will reappear.
Permissible ranges of temperature and humidity are as follows:
Cooling
Operation
Outdoor temperature: About 21 °C to 55 °C
Indoor temperature: About 18 °C to 35 °C
Indoor humidity: About 80 % or less. If the unit is used for long periods under conditions of high humidity, water may humidity, water
may condense on and drip from the surface of the unit.
Drying
Operation
Outdoor temperature: About 18 °C to 55 °C
Indoor temperature: About 18 °C to 35 °C
Indoor humidity: If the unit is used for long periods under conditions of high humidity, water may condense on and drip from the surface
of the unit.
If the unit is used under higher temperature conditions than those noted here, the automatic protection circuit may operate, interrupting the operation.
If the unit is used under lower temperature conditions than those noted here, the heat exchanger may freeze, causing water leakage or other malfunction.
Do not use the air conditioner for any purpose other than room cooling, room drying or fan.
WARNING
zIn order to enable effi cient and trouble-free operation of your air conditioner, connect the power plug of your air conditioner through an exclusive
circuit, having a time delay fuse, to the correct power supply described on the rating plate.
zThe circuit breaker with all pole disconnection must be incorporated in permanent wiring.
zIf the power supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualifi ed persons in order to avoid a
hazard.
zThis appliance shall be installed in accordance with national wiring regulations.
Connect BROWN line of the power supply cable to the “Live” terminal of the power outlet, and the earth (ground) line (GREEN and YELLOW) to
the earth (ground) terminal.
Remaining line should be connected to the neutral terminal of the power outlet.
Notes:
• In the following situation, the setting temperature will be 24ºC even if
you set the setting temperature lower than 24ºC.
—When changing the operation mode
—When stopping the operation once, then restart the operation
* When you change the setting temperature higher than 24 ºC, the
changed setting temperature will be saved.
The thermostat cannot be used to set room temperature during the FAN
mode (the temperature will not appear on the remote controller’s display.)
About 3 seconds later, the entire display will reappear.
The thermostat setting should be considered a standard value, and
may diff er somewhat from the actual room temperature.
Indicators
SUPER WAVE indicator will light.
SUPER WAVE indicator go out.
Produkt Specifikationer
Mærke: | Fujitsu |
Kategori: | Klimaanlæg |
Model: | AXGT24FHTC-B |
Har du brug for hjælp?
Hvis du har brug for hjælp til Fujitsu AXGT24FHTC-B stil et spørgsmål nedenfor, og andre brugere vil svare dig
Klimaanlæg Fujitsu Manualer
13 Oktober 2024
3 September 2024
23 August 2024
22 August 2024
22 August 2024
17 August 2024
13 August 2024
10 August 2024
10 August 2024
9 August 2024
Klimaanlæg Manualer
- Klimaanlæg DeLonghi
- Klimaanlæg Bosch
- Klimaanlæg Sencor
- Klimaanlæg TCL
- Klimaanlæg Zibro
- Klimaanlæg Siemens
- Klimaanlæg Day
- Klimaanlæg Samsung
- Klimaanlæg Wilfa
- Klimaanlæg GE
- Klimaanlæg Daikin
- Klimaanlæg Zanussi
- Klimaanlæg CyberPower
- Klimaanlæg Panasonic
- Klimaanlæg Gorenje
- Klimaanlæg Tectro
- Klimaanlæg VOX
- Klimaanlæg Concept
- Klimaanlæg OK
- Klimaanlæg LG
- Klimaanlæg AEG
- Klimaanlæg Electrolux
- Klimaanlæg Bauknecht
- Klimaanlæg Whirlpool
- Klimaanlæg Mitsubishi
- Klimaanlæg Master
- Klimaanlæg Sharp
- Klimaanlæg Hotpoint
- Klimaanlæg Melissa
- Klimaanlæg ARGO
- Klimaanlæg Qlima
- Klimaanlæg Daewoo
- Klimaanlæg Korona
- Klimaanlæg Arçelik
- Klimaanlæg Soler & Palau
- Klimaanlæg Sanyo
- Klimaanlæg Baxi
- Klimaanlæg Grundig
- Klimaanlæg Progress
- Klimaanlæg Hotpoint Ariston
- Klimaanlæg Livoo
- Klimaanlæg Toshiba
- Klimaanlæg Klarstein
- Klimaanlæg Furrion
- Klimaanlæg Infiniton
- Klimaanlæg Trisa
- Klimaanlæg Matsui
- Klimaanlæg Nedis
- Klimaanlæg Emerio
- Klimaanlæg Bartscher
- Klimaanlæg Be Quiet!
- Klimaanlæg Sauber
- Klimaanlæg Westinghouse
- Klimaanlæg Element
- Klimaanlæg Thomson
- Klimaanlæg Hyundai
- Klimaanlæg AKAI
- Klimaanlæg Hisense
- Klimaanlæg TriStar
- Klimaanlæg Brandt
- Klimaanlæg Adler
- Klimaanlæg Camry
- Klimaanlæg Dometic
- Klimaanlæg Eurom
- Klimaanlæg TecLime
- Klimaanlæg Trotec
- Klimaanlæg Blaupunkt
- Klimaanlæg Einhell
- Klimaanlæg Becken
- Klimaanlæg BEKO
- Klimaanlæg Honeywell
- Klimaanlæg Clatronic
- Klimaanlæg Hitachi
- Klimaanlæg Rowenta
- Klimaanlæg Ariston Thermo
- Klimaanlæg Haier
- Klimaanlæg Truma
- Klimaanlæg Bomann
- Klimaanlæg Innoliving
- Klimaanlæg Zelmer
- Klimaanlæg Vivax
- Klimaanlæg Thermex
- Klimaanlæg Vaillant
- Klimaanlæg Alaska
- Klimaanlæg Zanker
- Klimaanlæg Galanz
- Klimaanlæg Amana
- Klimaanlæg Amcor
- Klimaanlæg Carrier
- Klimaanlæg Comfee
- Klimaanlæg Gree
- Klimaanlæg Dimplex
- Klimaanlæg Tripp Lite
- Klimaanlæg Primo
- Klimaanlæg Orbegozo
- Klimaanlæg Malmbergs
- Klimaanlæg Sigma
- Klimaanlæg Koenig
- Klimaanlæg Taurus
- Klimaanlæg Xiaomi
- Klimaanlæg Exquisit
- Klimaanlæg HQ
- Klimaanlæg Proklima
- Klimaanlæg Elba
- Klimaanlæg Air Breeze
- Klimaanlæg Inventor
- Klimaanlæg MPM
- Klimaanlæg Toyotomi
- Klimaanlæg Frigor
- Klimaanlæg TOSOT
- Klimaanlæg APC
- Klimaanlæg Domo
- Klimaanlæg Ferroli
- Klimaanlæg Saunier Duval
- Klimaanlæg Heylo
- Klimaanlæg Olimpia Splendid
- Klimaanlæg Aspes
- Klimaanlæg Eden
- Klimaanlæg Blumfeldt
- Klimaanlæg Inventum
- Klimaanlæg Altech
- Klimaanlæg Carson
- Klimaanlæg Fakir
- Klimaanlæg White Knight
- Klimaanlæg Dantherm
- Klimaanlæg Khind
- Klimaanlæg Midea
- Klimaanlæg Frigidaire
- Klimaanlæg Frilec
- Klimaanlæg Evolar
- Klimaanlæg Ridgid
- Klimaanlæg Ardes
- Klimaanlæg Suntec
- Klimaanlæg SVAN
- Klimaanlæg Everglades
- Klimaanlæg Danby
- Klimaanlæg RCA
- Klimaanlæg ECG
- Klimaanlæg General Electric
- Klimaanlæg Eldom
- Klimaanlæg H.Koenig
- Klimaanlæg Sonnenkönig
- Klimaanlæg Termozeta
- Klimaanlæg OneConcept
- Klimaanlæg Stirling
- Klimaanlæg Just Fire
- Klimaanlæg Be Cool
- Klimaanlæg Duux
- Klimaanlæg ElectriQ
- Klimaanlæg Kalorik
- Klimaanlæg Cecotec
- Klimaanlæg Airwell
- Klimaanlæg Anslut
- Klimaanlæg MundoClima
- Klimaanlæg Jocca
- Klimaanlæg SereneLife
- Klimaanlæg Remko
- Klimaanlæg Friedrich
- Klimaanlæg Whynter
- Klimaanlæg Philco
- Klimaanlæg Fuave
- Klimaanlæg Avidsen
- Klimaanlæg Climadiff
- Klimaanlæg Kogan
- Klimaanlæg Ravanson
- Klimaanlæg Airlux
- Klimaanlæg Jocel
- Klimaanlæg Ufesa
- Klimaanlæg Keystone
- Klimaanlæg ActronAir
- Klimaanlæg Orava
- Klimaanlæg NewAir
- Klimaanlæg Create
- Klimaanlæg Daitsu
- Klimaanlæg Daizuki
- Klimaanlæg Profile
- Klimaanlæg AireMax
- Klimaanlæg Aconatic
- Klimaanlæg Aermec
- Klimaanlæg Acson
- Klimaanlæg Andrews
- Klimaanlæg Akira
- Klimaanlæg Aircooler
- Klimaanlæg Airview
- Klimaanlæg Aertesi
- Klimaanlæg Royal Sovereign
- Klimaanlæg Alberello
- Klimaanlæg Salton
- Klimaanlæg Haverland
- Klimaanlæg Rasonic
- Klimaanlæg Mabe
- Klimaanlæg Heinner
- Klimaanlæg Nabo
- Klimaanlæg AlpicAir
- Klimaanlæg Kelvinator
- Klimaanlæg Tatung
- Klimaanlæg Milectric
- Klimaanlæg Lloyd
- Klimaanlæg Alpatec
- Klimaanlæg Godrej
- Klimaanlæg Maiko
- Klimaanlæg Aircool
- Klimaanlæg Edgestar
- Klimaanlæg Maxicool
- Klimaanlæg Argoclima
- Klimaanlæg Home Electric
- Klimaanlæg Tarrington House
- Klimaanlæg Gutfels
- Klimaanlæg Telair
- Klimaanlæg Klarbach
- Klimaanlæg Mobile Airco
- Klimaanlæg Heiko
- Klimaanlæg Qlima - Zibro
- Klimaanlæg VänEE
- Klimaanlæg Handson
- Klimaanlæg Bryant
- Klimaanlæg Klima1stKlaas
- Klimaanlæg Emmeti
- Klimaanlæg Evapolar
- Klimaanlæg ARCTIC WIND
- Klimaanlæg Perfect Aire
- Klimaanlæg TechnoLife
- Klimaanlæg Shinco
- Klimaanlæg Innova
- Klimaanlæg D-Let
- Klimaanlæg Domair
- Klimaanlæg SEEGER
- Klimaanlæg Thermo Comfort
- Klimaanlæg Mizushi
- Klimaanlæg Sinclair
- Klimaanlæg Arcoaire
- Klimaanlæg Zymbo
- Klimaanlæg GoldAir
- Klimaanlæg Kostal
- Klimaanlæg SMD
- Klimaanlæg Commercial Cool
- Klimaanlæg Coolix
- Klimaanlæg Omega Altise
- Klimaanlæg Koldfront
- Klimaanlæg Yamazen
- Klimaanlæg Corona
Nyeste Klimaanlæg Manualer
21 November 2024
21 November 2024
21 November 2024
20 November 2024
20 November 2024
20 November 2024
20 November 2024
20 November 2024
18 November 2024
18 November 2024