2. Sensor image settings
and Motor-zoom control
User can set sensor parameters in "Live" tab by clicking right
mouse button on Live image and selecting " " from Sensor
context menu, like shown on below picture. It will show popup
window with sensor parameters which we can modify.
This menu provides possibility to control lens Motor-zoom
(depends on camera model).
To modify sensor parameters we must to change mode from ,
standard to " in configuration menu Debug Mode" .
4. Setting IP address in camera:
- Using web browser
In tab expand menu and select Configuration Device
Local Network option To set static IP address You must to .
disable client mode by moving switch to DHCP OFF
position. Next You must to enter planned IP addresses to
camera configuration You must to remember to fill correctly .
available fields with acceptable addresses (add likeress
"0.0.0.0" not complete are not allowedor ).
! Basic informations about IP addresses
For addressing You should use addresses containing 4
segments separated by " " sign. which should be compatible dot
with standard address rule in LAN network Using not complete .
addresses or containing less than 4 segments separation sign ,
will be other from " will be used "dot or restricted IP add sre s
starting with "0" ( . 0.1.2.3) ending on "255" (ex. ex or
8.8.8.255), will cause an error when saving configuration by
clicking - ."Apply" button
Configuration menu is displayed like showed below.
- Using dedicated tool attached on CD
"GANZ-ZN8-series_IPSearchTool"
You need to run application from attached CD In tool menu .
You need to click " " button After camera search, You Start .
need to select device in which we want to change IP setting (in
" " column, there are typed Device ID end segments of
device MAC address) and input planned address to camera
configuration, which we applies by clicking " " button. Modify
5. Video Streams configuration
In tab expand menu and select Configuration Stream
Base Stream option First of all You need to decide which .
stream You want to modify by selecting Stream ID
dropdown list After parameter configuration You need to save . ,
settings for each stream separately by clicking " " button. Apply
Next streams parameters we can define in the same way by
changing ID and saving parameters like before.
GANZ ZN8-series IPC
Quick Start
1. Log to camera WWW interface in
Open web browser type camera IP address (default - ,
http://192.168.1.168) in browsers address field
and click Enter key.
! Warning - one IP address and two cameras
Two cameras cannot work with the same IP address in one
network In this case You should add cameras "one by one" .
and modify their IP addresses manually or use dedicated tool -
GANZ-ZN8-series_IPSearchTool (attached on CD).
Login page displays like showed below.
Enter username and password.
Default login credentials - ADMIN / 1234.
Change password after first login to camera to ensure system
security.
You can change language in camera menu on login page.
Click on Login button.
Main page will be displayed.
! Warning - IP address and DHCP
Camera has enabled by default DHCP client feature what
means, when we connect camera to network in which works
DHCP server (ex. router) then camera recive address from this
network pool and for discover it we need to use dedicated tool t
- (attached on CD).GANZ-ZN8-series_IPSearchTool
Mind you respected user, important operations and
maintenance (repair) guide are described in the
attached product instruction.
Mind you respected user, uninsulated "dangerous
voltage" exists, please be aware of electric shock.
- Power supply must pass safety certification ,Its output
voltage, current, voltage polarity and operating temperature
must match requirement of this equipment.
- Please install lightning protection devices or cut off the
power in thunder and lightning conditions.
- To capture high-quality video and pictures, please make
sure the network connection is stable and smooth.
- To prevent the sensor pull light phenomenon, prohibit
putting the lens under bright light for a long time.
- The equipment must not be installed under the air door of
air conditioner , otherwise the lens will become blurry and
condenses into moisture.
- When install, repair or clean the equipment, please make
sure the power has been turned off.
- Prohibit putting this equipment to work in strong magnetic
field and laser beam environment.
3. OSD configuration
In tab expand menu and select Configuration Device
OSD option. Here You can decide which elements should be
visible on camera image and their parameters.


Produkt Specifikationer

Mærke: Ganz
Kategori: Overvågningskamera
Model: Genstar ZN8-M4NTFN4L

Har du brug for hjælp?

Hvis du har brug for hjælp til Ganz Genstar ZN8-M4NTFN4L stil et spørgsmål nedenfor, og andre brugere vil svare dig




Overvågningskamera Ganz Manualer

Overvågningskamera Manualer

Nyeste Overvågningskamera Manualer

Sony

Sony SNC-DH160 Manual

16 November 2024
Bresser

Bresser DL-30MP Manual

15 November 2024
D-Link

D-Link DCS-6500LHV2 Manual

14 November 2024
D-Link

D-Link DCS-2803KT Manual

13 November 2024
D-Link

D-Link DCS-2804KT Manual

13 November 2024
D-Link

D-Link DCS-931L Manual

13 November 2024
D-Link

D-Link DCS-6100LHV2 Manual

13 November 2024
Emos

Emos H4060 Manual

13 November 2024